Raritan PX3-5660V-C1 Monitored 30-Outlet Rack PDU - 8. 60 kVA - 230V AC Input - 21x C13 - 6x C19 - 3x NEMA 5-20R - 0U Vertical Mount
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This PDU operates on a three-phase power system with a NEMA L21-30P (4P5W) plug, ensuring robust electrical connectivity. It offers comprehensive protection through overload, overcurrent, and double-pole safeguards, maintaining equipment safety under varying load conditions.
The 30A input current supports the 8.60 kVA rating, making it suitable for high-density rack deployments. Network management is enabled via an RJ-45 port, supporting multiple protocols including SNMPv3, MODBUS/TCP, and SSH for integration into existing monitoring systems.
This section brings together practical product details such as PDU Type, Phase, Plug/Connector Type, Input Voltage, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
A strong technical summary explains how the product's interfaces, hardware profile, and operating characteristics work together in real deployment. Buyers often need this context to confirm compatibility with existing devices, expected performance in daily use, and whether installation will be straightforward for IT staff or end users.
Key Product Advantages
The PX3-5660V-C1 combines high power capacity with advanced monitoring features, offering significant advantages for IT infrastructure management. Its remote outlet switching capability allows administrators to power cycle devices without physical access, reducing downtime and maintenance costs.
For buyers comparing similar models, the strongest advantage is usually the balance between dependable day-to-day operation and a simpler rollout experience. That means less time spent troubleshooting fit, compatibility, or user adoption after installation, which is especially important for shared business environments and repeat purchasing decisions.
Advantages are also easier to justify when they translate into measurable operational value, such as less downtime, more consistent user experience, easier replacement planning, or better alignment with existing accessories and workflows. That practical value tends to matter more than broad marketing language when teams are standardizing purchases.
Deployment / Use Cases
This PDU is ideal for data centers, server rooms, and network closets where reliable power distribution and management are critical. Its 8.60 kVA capacity and 30 outlets make it suitable for high-density racks housing servers, storage arrays, and networking switches.
The vertical mounting orientation and 0U rack height allow it to be installed in standard 19-inch racks without consuming U space, maximizing equipment density. Use cases include enterprise IT environments, colocation facilities, and any setting requiring scalable power management with remote capabilities.
Data Center Racks
Deploy in server racks to distribute power to multiple devices while monitoring consumption and controlling outlets remotely.
Network Infrastructure
Use in network closets to power switches, routers, and other gear, with management via SNMP or SSH for integration into network monitoring tools.
Physical Profile
The PDU features a compact vertical design with dimensions of 70.10" height, 2.10" width, and 2.60" depth, weighing approximately 15.43 lb. Its 0U rack-mountable form factor allows installation along the side of a rack, preserving vertical space for other equipment. The vertical mounting orientation ensures efficient cable management and airflow in tight rack environments.
The physical profile is practical for deployment planning because the dimensions and weight are clearly defined: 0U, 2.10" (53.34 mm), 2.60" (66.04 mm), 15.43 lb (7000 g). This helps confirm rack, shelf, desk, or cabinet fit before installation.
- Width
- 2.10" (53.34 mm)
- Depth
- 2.60" (66.04 mm)
- Height
- 0U
- Weight
- 15.43 lb (7000 g)
Highlights
- 8.60 kVA power capacity for high-density rack deployments.
- 30 total outlets: 21 IEC C13, 6 IEC C19, 3 NEMA 5-20R.
- Monitored PDU with remote outlet switching capability.
- Network management via RJ-45 with multiple protocol support.
- Three-phase input, 230V AC to 208V AC output.
- Vertical 0U rack mounting saves space.
- Overload, overcurrent, and double-pole protection.
- 2-year limited warranty for reliability assurance.
Specifications
| Specifications | |
|---|---|
| Manufacturer | Legrand Group |
| Manufacturer Part Number | PX3-5660V-C1 |
| Brand Name | Raritan |
| Product Series | PX3 |
| Product Name | PX3 30-Outlets PDU |
| Product Type | PDU |
| Technical Information | |
| PDU Type | Monitored |
| Phase | Three Phase |
| Plug/Connector Type | NEMA L21-30P (4P5W) |
| Receptacle Type | IEC 60320 C13,IEC 60320 C19,NEMA 5-20R |
| Receptacle Detail | 21 x IEC 60320 C13,6 x IEC 60320 C19,3 x NEMA 5-20R |
| Protection Type | Overload Protection,Overcurrent Protection,Double Pole |
| Power Description | |
| Input Voltage | 230 V AC |
| Output Voltage | 208 V AC |
| Power Rating (VA) | 8.60 kVA |
| Input Current | 30 A |
| Management | |
| Management | HTML JSON-RPC SSH Telnet MODBUS/TCP SNMPv3 TFTP DHCP SSH(CLI) |
| Remote Outlet Switching | Yes |
| Interfaces/Ports | |
| Network (RJ-45) | Yes |
| Physical Characteristics | |
| Mounting Orientation | Vertical |
| Mount Type | Rack-mountable |
| Rack Height | 0U |
| Height | 70.10" (1780.54 mm) |
| Width | 2.10" (53.34 mm) |
| Depth | 2.60" (66.04 mm) |
| Weight (Approximate) | 15.43 lb (7000 g) |
| Warranty | |
| Limited Warranty | 2 Year |
User Manual
FAQ
What is the power capacity of this PDU?
The Raritan PX3-5660V-C1 has a power rating of 8.60 kVA, with an input voltage of 230V AC and output voltage of 208V AC. This capacity supports high-power equipment in data center racks, making it suitable for servers and networking gear that require stable three-phase power distribution.
How many outlets does this PDU have and what types?
This PDU features 30 total outlets: 21 IEC 60320 C13 receptacles, 6 IEC 60320 C19 receptacles, and 3 NEMA 5-20R receptacles. This mix accommodates a variety of devices, from standard servers to high-power equipment, providing flexible connectivity options in rack environments.
Can I remotely control the outlets on this PDU?
Yes, the PDU supports remote outlet switching, allowing administrators to power cycle individual outlets via network management. This feature enables troubleshooting and maintenance without physical access to the rack, reducing downtime and improving operational efficiency in data centers.
What management protocols are supported?
The PDU supports multiple management protocols including HTML, JSON-RPC, SSH, Telnet, MODBUS/TCP, SNMPv3, TFTP, DHCP, and SSH(CLI). This wide compatibility allows integration into existing monitoring systems, enabling centralized power management and real-time data collection.
How is this PDU mounted in a rack?
This PDU is designed for vertical mounting with a 0U rack height, meaning it installs along the side of a standard 19-inch rack without consuming vertical U space. Its dimensions are 70.10" height, 2.10" width, and 2.60" depth, making it ideal for space-constrained environments.
What protection features does this PDU offer?
The PDU includes overload protection, overcurrent protection, and double-pole protection to safeguard connected equipment from electrical faults. These features help prevent damage due to power surges or excessive loads, ensuring reliable operation in critical IT infrastructure.
What power capacity is listed for this UPS?
The listed power specification is 8.60 kVA, which helps position the unit for the right load level and installation role.
How many outlets are available?
The product includes Yes, which helps buyers understand how many connected devices it can support in its intended deployment.