Product Features
Technical Overview
Relevant factors for this section include PDU Type, Plug/Connector Type, Protection Type, Input Voltage. When those points are considered together, they give buyers a clearer picture of how the product is equipped, how it fits into deployment, and what kind of day-to-day role it is meant to support.
Power Specifications
The AP8865 accepts 208V 3-phase 30A input via a NEMA L21-30P connector and distributes power at both 120V and 208V AC. The unit provides overload protection to safeguard connected equipment against power surges and excessive current draw.
- Input: 208V 3-phase 30A
- Output: 120V AC, 208V AC
- Total capacity: 8.6kW
- Protection: Overload protection
Physical Design
Engineered for zero rack unit consumption, this PDU mounts vertically on the side of standard 19-inch server racks. The slim 2.20-inch profile minimizes space usage while the 70.51-inch height accommodates full-height rack configurations.
- Rack height: 0U
- Mounting: Vertical side-mount
- Weight: 16.67 lb (7.56 kg)
- Cord length: 6 ft (1.82 m)
Key Product Advantages
The AP8865 metered rack PDU combines high-density power distribution with advanced monitoring capabilities for modern data center infrastructure. The unit's precise metering with ±3% accuracy enables accurate capacity planning and load balancing across circuits, helping optimize power utilization and prevent overload conditions.
These strengths make the product easier to deploy and manage in real environments, especially where reliability, usability, and day-to-day operational continuity matter. Notable benefits include Real-time remote monitoring, Alarm threshold configuration, Embedded log memory, EcoStruxure IT compatible, Toolless installation.
For buyers comparing similar models, the strongest advantage is usually the balance between dependable day-to-day operation and a simpler rollout experience. That means less time spent troubleshooting fit, compatibility, or user adoption after installation, which is especially important for shared business environments and repeat purchasing decisions.
Deployment / Use Cases
This metered rack PDU is engineered for deployment in colocation facilities, large enterprise data centers, and distributed IT sites where precise power monitoring and high-density outlet configurations are essential. The 44-outlet design supports dense server and networking deployments, while the 0U vertical mounting preserves valuable rack space for equipment.
The AP8865 integrates seamlessly with Schneider Electric's EcoStruxure IT platform and other monitoring systems, providing visibility into power consumption patterns and enabling proactive capacity management. IT teams can use the real-time data to identify underutilized circuits, balance loads across phases, and plan for infrastructure expansion with accurate power usage information.
Data Center Power Management
Deploy in server racks to monitor power consumption per circuit, track energy usage for billing or reporting, and receive alerts when loads approach capacity limits.
High-Density Equipment Support
Power multiple servers, switches, and storage devices from a single PDU with the mixed outlet configuration supporting both C13 and C19 connections.
Physical Profile
The AP8865 features a vertical side-mount design that installs without consuming rack units, preserving all front and rear rack space for equipment. The unit measures 70.51 inches in height to match standard rack dimensions, with a slim 2.20-inch width and 1.81-inch depth that minimizes obstruction in the rack aisle. The 6-foot power cord provides flexibility in rack placement relative to power sources.
- Width
- 2.20" (56 mm)
- Depth
- 1.81" (46 mm)
- Height
- 0U
- Weight
- 16.67 lb (7561.38 g)
- Length
- 6 ft (1.82 m)
What's in the Box
The package includes all necessary components for immediate deployment and configuration.
Highlights
- 8.6kW 208V 3-phase power capacity for high-density racks
- 44 total outlets: 36 C13, 6 C19, and 2 NEMA 5-20R
- Metered design with ±3% accuracy for precise load monitoring
- 0U vertical side-mount preserves rack space for equipment
- Remote management via SNMP and Telnet protocols
- Interactive LCD displays real-time power measurements
- Overload protection safeguards connected equipment
- EcoStruxure IT compatible for integrated monitoring
- Toolless installation simplifies deployment
- 2-year APC warranty with RoHS compliance
Specifications
| Specifications | |
|---|---|
| Manufacturer | Schneider Electric SA |
| Manufacturer Part Number | AP8865 |
| Brand Name | APC by Schneider Electric |
| Product Line | Metered Rack |
| Product Model | AP8865 |
| Product Name | Metered Rack AP8865 44-Outlets PDU |
| Product Type | PDU |
| Technical Information | |
| PDU Type | Metered |
| Plug/Connector Type | NEMA L21-30P |
| Protection Type | Overload Protection |
| Power Description | |
| Input Voltage | 208 V |
| Output Voltage | 120 V AC,208 V AC |
| Management | |
| Management | Protocolos: SNMP Telnet |
| Physical Characteristics | |
| Mounting Orientation | Vertical |
| Mount Type | Rack-mountable |
| Placement | Side |
| Rack Height | 0U |
| Cord Length | 6 ft (1.82 m) |
| Height | 70.51" (1791 mm) |
| Width | 2.20" (56 mm) |
| Depth | 1.81" (46 mm) |
| Weight (Approximate) | 16.67 lb (7561.38 g) |
| Miscellaneous | |
| Package Contents | Metered Rack AP8865 44-Outlets PDU Installation guide Rack mounting brackets Safety guide Serial configuration cable |
| Country of Origin | India |
| Environmentally Friendly | Yes |
| Environmental Compliance | Restriction of Hazardous Substances (RoHS) |
| Warranty | |
| Limited Warranty | 2 Year |
User Manual
FAQ
What is the total power capacity of the AP8865 PDU?
The APC AP8865 provides 8.6kW of power capacity with a 208V 3-phase 30A input. This substantial capacity supports high-density server racks and networking equipment in data center environments, delivering both 120V and 208V AC output to accommodate various device requirements.
How many outlets does this rack PDU have and what types are included?
This PDU features 44 total outlets with a mixed configuration: 36 C13 outlets, 6 C19 outlets, and 2 NEMA 5-20R outlets. This combination supports a wide range of server, networking, and peripheral equipment commonly found in data center racks, providing flexibility for different power cord types.
What rack space does the AP8865 consume during installation?
The AP8865 is a 0U vertical side-mount PDU that installs on the side of standard 19-inch server racks without consuming any rack units. This design preserves all front and rear rack space for equipment while providing full-height power distribution along the 70.51-inch vertical dimension.
What monitoring capabilities does this metered PDU offer?
This metered PDU provides real-time monitoring of voltage, current, kilowatts, and kilowatt-hours with ±3% accuracy. The interactive LCD displays these measurements locally, while SNMP and Telnet protocols enable remote monitoring through network management systems like EcoStruxure IT. The embedded log memory stores historical data for analysis.
What input power connection does the AP8865 require?
The AP8865 uses a NEMA L21-30P connector for 208V 3-phase 30A input power. This industrial-grade connector is standard for three-phase power distribution in data centers and supports the unit's 8.6kW capacity. The included 6-foot power cord provides installation flexibility relative to power sources.
What management features help prevent circuit overloads?
The AP8865 allows administrators to define custom alarm thresholds for current, voltage, and power consumption. When measurements approach these limits, the system can trigger alerts via the network management interface, enabling proactive load balancing or equipment redistribution before overload conditions occur. The overload protection circuitry provides additional hardware safety.