CyberPower PDU33110 Monitored PDU - 3 Phase 200-240V 60A - 18 Outlets - 6x C13 + 12x C19 - 0U Vertical Rackmount - 10 ft Cord - 3-Year Warranty
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This three-phase PDU operates on a 200-240V AC input range with a nominal 230V AC rating, delivering consistent output voltage across the same range. The 60A input current supports high-density power requirements, while the 60Hz input frequency aligns with North American power standards. Overload protection and cord retention trays on all outlets prevent accidental disconnections and safeguard connected equipment.
Network management is extensive, supporting IPv4 and IPv6 with protocols including SNMPv1/v3, HTTP/HTTPS, SSH, SSL/TLS, LDAP(S), RADIUS, Syslog, and CLI. This allows integration into existing data center management systems for real-time monitoring, alerting via email or SMS, and centralized control. The modular design facilitates maintenance and future upgrades without disrupting the entire power distribution chain.
This section brings together practical product details such as PDU Type, Design, Phase, Input Voltage, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
Key Product Advantages
The PDU33110 combines high-capacity three-phase power distribution with advanced monitoring in a space-saving 0U vertical form factor. Its 18-outlet configuration accommodates diverse equipment types, while the monitored capabilities provide actionable insights into power usage and health.
High-Density Power Distribution
Delivers 60A across 18 outlets (6 C13, 12 C19) to support multiple servers, switches, and storage devices in a single rack.
- Three-phase efficiency for balanced loads
- Cord retention trays secure connections
- Overload protection prevents circuit tripping
Comprehensive Remote Management
Enables monitoring and control via SNMP, HTTP, SSH, and other protocols, with alerting for power events and environmental conditions.
- Email and SMS notifications
- Integration with data center management tools
- Real-time load and status reporting
Deployment / Use Cases
The CyberPower PDU33110 is designed for environments where reliable, monitored power distribution is critical. Its three-phase input and high outlet count make it suitable for server racks, network closets, and data center cabinets supporting compute and storage infrastructure.
Ideal for IT administrators managing rack-mounted equipment, this PDU provides the capacity to power multiple high-draw devices while offering visibility into power consumption and health. The vertical 0U mounting preserves valuable rack space for additional equipment, and the 10-foot cord allows flexible placement relative to power sources. Use cases include enterprise server rooms, colocation facilities, and network operations centers where power redundancy and monitoring are priorities.
Data Center Server Racks
Distributes three-phase power to multiple servers and storage arrays with monitoring for uptime and efficiency.
Network Equipment Cabinets
Powers switches, routers, and other network gear while providing alerts on power status and load conditions.
Physical Profile
The PDU33110 features a vertical 0U rackmount design with dimensions of 2.20" wide, 70.50" high, and 2.20" deep, making it ideal for mounting on the side of standard 19-inch racks without consuming rack units. Its black finish blends with typical rack hardware, and the 10-foot power cord provides installation flexibility. Weighing approximately 19.20 lb, the unit is robust yet manageable for rack integration. Operating temperature ranges from 23°F to 131°F, ensuring reliability in controlled data center environments.
- Width
- 2.20" (55.88 mm)
- Depth
- 2.20" (55.88 mm)
- Height
- 0U
- Weight
- 19.20 lb (8708.97 g)
- Length
- 10 ft (3.05 m)
Highlights
- Three-phase 200-240V AC input with 60A current capacity
- 18 total outlets: 6 IEC 60320 C13 and 12 IEC 60320 C19
- 0U vertical rackmount design saves rack space
- Monitored PDU with network management via RJ-45
- Supports SNMP, HTTP, SSH, and other management protocols
- Overload protection and cord retention trays enhance safety
- 10-foot power cord with IEC-309 60A blue input connector
- 3-year limited warranty for long-term reliability
- RoHS compliant and environmentally friendly
- Operating temperature range: 23°F to 131°F (-5°C to 55°C)
Specifications
| Specifications | |
|---|---|
| Manufacturer | CyberPower Systems, Inc |
| Manufacturer Part Number | PDU33110 |
| Brand Name | CyberPower |
| Product Series | Monitored PDU |
| Product Model | PDU33110 |
| Product Name | PDU33110 3 Phase 200 - 240 VAC 60A Monitored |
| Product Condition | New |
| Product Type | PDU |
| Technical Information | |
| PDU Type | Monitored |
| Design | Modular |
| Phase | Three Phase |
| Plug/Connector Type | IEC-309 60A BLUE (3P+E) |
| Receptacle Type | IEC 60320 C13 |
| Receptacle Detail | 6 x IEC 60320 C13,12 x IEC 60320 C19 |
| Protection Type | Overload Protection |
| Locking Receptacles | Cord Retention Tray |
| Features | LED Status Indicator |
| Power Description | |
| Input Voltage | 230 V AC |
| Input Voltage Range | 200 V AC - 240 V AC |
| Output Voltage | 200 V AC,240 V AC |
| Output Voltage Range | 200 V AC - 240 V AC |
| Input Current | 60 A |
| Input Frequency | 60 Hz |
| Management | |
| Management | Protocols: IPv4 TCP IP UDP SNMPv1 HTTP NTP DNS Telnet DHCP SMTP FTP IPv6 SNMPv3 HTTPs SSH SSL TLS LDAP(S) RADIUS Syslog CLI Windows AD SNMP |
| Interfaces/Ports | |
| Network (RJ-45) | Yes |
| Physical Characteristics | |
| Color Family | Black |
| Product Color | Black |
| Mounting Orientation | Vertical |
| Mount Type | Rack-mountable |
| Rack Height | 0U |
| Cord Length | 10 ft (3.05 m) |
| Height | 70.50" (1790.70 mm) |
| Width | 2.20" (55.88 mm) |
| Depth | 2.20" (55.88 mm) |
| Weight (Approximate) | 19.20 lb (8708.97 g) |
| Environmental Conditions | |
| Minimum Operating Temperature | 23°F (-5°C) |
| Maximum Operating Temperature | 131°F (55°C) |
| Minimum Storage Temperature | -4°F (-20°C) |
| Maximum Storage Temperature | 113°F (45°C) |
| Miscellaneous | |
| Application/Usage | Network Device,Server,Data Center |
| Country of Origin | China |
| Environmentally Friendly | Yes |
| Environmental Compliance | Restriction of Hazardous Substances (RoHS) |
| Warranty | |
| Limited Warranty | 3 Year |
User Manual
FAQ
What is the input voltage range for this PDU?
The CyberPower PDU33110 accepts a three-phase input voltage range of 200-240V AC, with a nominal rating of 230V AC. This range is compatible with standard North American three-phase power systems, providing stable output voltage across the same range for connected equipment.
How many outlets does this PDU have and what types?
This PDU features 18 total outlets: six IEC 60320 C13 receptacles and twelve IEC 60320 C19 receptacles. The C13 outlets are typical for servers and network devices, while the C19 outlets support higher-power equipment like larger servers and storage arrays, offering flexibility for mixed IT environments.
What does 'monitored' mean for this PDU?
Monitored indicates that the PDU33110 includes network management capabilities via an RJ-45 port, allowing remote monitoring of power status, load conditions, and environmental metrics. It supports protocols like SNMP, HTTP, SSH, and others for integration into data center management systems, with alerting via email or SMS for power events.
How is this PDU mounted in a rack?
The PDU33110 is designed for vertical 0U rackmount installation, meaning it mounts on the side of a standard 19-inch rack without consuming any rack units. This space-saving design preserves rack space for servers and other equipment, with a vertical orientation that accommodates its 70.50-inch height.
What management protocols are supported?
This PDU supports a wide range of management protocols including IPv4 and IPv6, SNMPv1/v3, HTTP/HTTPS, SSH, SSL/TLS, LDAP(S), RADIUS, Syslog, CLI, and more. This enables comprehensive remote monitoring, configuration, and alerting, integrating seamlessly into existing IT management infrastructures.
What is the warranty period for this PDU?
The CyberPower PDU33110 comes with a 3-year limited warranty, covering defects in materials and workmanship. This warranty provides assurance for long-term reliability in data center and server room deployments, backed by CyberPower's support for power protection products.
What power capacity is listed for this UPS?
Power specifications help show where the unit fits best, including the type of load level, electrical environment, and backup role it is intended to support. These are usually the most decision-critical facts in a UPS or power-protection comparison.
What voltage details are listed?
The listed power specification is 230 V AC, which helps position the unit for the right load level and installation role.