CyberPower PDU83107 Switched Metered-by-Outlet PDU - 3-Phase 200-240V 50A - 30 Outlets - 24x C13 + 6x C19 - 0U Vertical Rackmount - 10 ft Cord
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This switched metered-by-outlet PDU provides advanced power management through support for IPv4 and IPv6 networking protocols, including SNMPv1/v3, HTTP/HTTPS, SSH, SSL/TLS, and LDAP(S). The system enables granular monitoring of power consumption at each individual outlet, allowing administrators to identify inefficient devices, balance loads, and implement power scheduling policies.
The unit incorporates overload protection to safeguard connected equipment against power surges and excessive current draw. Its Hubbell CS8365C input connector ensures reliable connection to 3-phase power sources, while the 10-foot power cord provides flexible placement options within the rack environment.
Relevant factors for this section include PDU Type, Phase, Plug/Connector Type, Input Voltage. When those points are considered together, they give buyers a clearer picture of how the product is equipped, how it fits into deployment, and what kind of day-to-day role it is meant to support.
Key Product Advantages
The PDU83107 delivers superior power management capabilities through its combination of switched functionality and outlet-level metering. This dual capability allows data center operators to not only control power to individual devices but also monitor exact power consumption at each outlet, enabling precise capacity planning and energy optimization.
Granular Power Monitoring
Monitor real-time power consumption at each of the 30 outlets to identify inefficient devices, balance electrical loads across phases, and accurately forecast power requirements for future expansions.
- Outlet-level power metering
- Real-time consumption data
- Historical usage tracking
Comprehensive Remote Management
Control and monitor the PDU from anywhere using industry-standard protocols including SNMP, HTTP/HTTPS, SSH, and Telnet. Schedule power cycles, implement graceful shutdowns, and receive alerts via email, SMS, or SNMP traps.
- Multi-protocol support
- Scheduled power cycling
- Alert notifications
Space-Efficient Design
The 0U vertical mounting orientation and slim 2.2-inch profile maximize usable rack space while providing power distribution to an entire rack of equipment. The vertical design improves airflow management compared to horizontal PDUs.
- Zero rack units consumed
- Improved airflow
- High outlet density
Deployment / Use Cases
The CyberPower PDU83107 is ideally suited for data centers, server rooms, and network closets where precise power management and high outlet density are required. Its 3-phase power capability makes it particularly valuable for environments with high-power computing equipment, storage arrays, or networking gear that demands reliable, monitored power distribution.
In colocation facilities, this PDU enables providers to offer detailed power usage reporting to customers while maintaining the ability to remotely reboot individual customer devices. For enterprise IT departments, the outlet-level metering helps identify underutilized equipment for consolidation and supports green initiatives through accurate energy consumption tracking.
Data Center Power Distribution
Distribute 3-phase power to high-density server racks while monitoring consumption at each outlet to optimize power usage effectiveness (PUE) and prevent circuit overloads.
Remote Site Management
Manage power to equipment in branch offices, retail locations, or edge computing sites from a central location, reducing the need for onsite technical visits for routine power management tasks.
Physical Profile
The PDU83107 features a durable black housing designed for vertical mounting in standard 19-inch equipment racks. With dimensions of 70.50 inches in height and just 2.20 inches in width and depth, the unit provides maximum outlet density without consuming valuable horizontal rack space. The 10-foot input power cord offers installation flexibility, while the RoHS-compliant construction ensures environmental responsibility.
The physical profile is practical for deployment planning because the dimensions and weight are clearly defined: 0U, 2.20" (55.88 mm), 2.20" (55.88 mm), 19.40 lb (8799.69 g). This helps confirm rack, shelf, desk, or cabinet fit before installation.
- Width
- 2.20" (55.88 mm)
- Depth
- 2.20" (55.88 mm)
- Height
- 0U
- Weight
- 19.40 lb (8799.69 g)
- Length
- 10 ft (3.05 m)
Highlights
- 3-phase power distribution with 200-240V 50A input capacity
- Switched metered-by-outlet design for individual outlet control and monitoring
- 30 total outlets: 24 IEC C13 and 6 IEC C19 receptacles
- 0U vertical rackmount installation conserves horizontal rack space
- Comprehensive network management via SNMP, HTTP/HTTPS, SSH, and more
- Hubbell CS8365C input connector for reliable 3-phase connection
- 10-foot power cord for flexible placement within racks
- Overload protection safeguards connected equipment
- LCD display for local power monitoring and configuration
- 3-year limited warranty for long-term reliability
Specifications
| Specifications | |
|---|---|
| Manufacturer | CyberPower Systems, Inc |
| Manufacturer Part Number | PDU83107 |
| Brand Name | CyberPower |
| Product Series | Switched Metered-by-Outlet PDU |
| Product Model | PDU83107 |
| Product Name | PDU83107 3 Phase 200 - 240 VAC 50A Switched Metered-by-Outlet |
| Product Condition | New |
| Product Type | PDU |
| Technical Information | |
| PDU Type | Switched with Metered-by-Outlet |
| Phase | Three Phase |
| Plug/Connector Type | Hubbell CS8365C |
| Receptacle Type | IEC 60320 C13,IEC 60320 C19 |
| Receptacle Detail | 24 x IEC 60320 C13,6 x IEC 60320 C19 |
| Protection Type | Overload Protection |
| Power Description | |
| Input Voltage | 230 V AC |
| Input Voltage Range | 200 V AC - 240 V AC |
| Output Voltage Range | 200 V AC - 240 V AC |
| Input Current | 50 A |
| Management | |
| Management | IPv4 TCP/IP UDP SNMPv1 HTTP NTP DNS Telnet DHCP SMTP FTP IPv6 SNMPv3 HTTPs SSH SSL TLS LDAP(S) RADIUS Syslog CLI Windows AD |
| Remote Outlet Switching | Yes |
| Interfaces/Ports | |
| Network (RJ-45) | Yes |
| Physical Characteristics | |
| Color Family | Black |
| Product Color | Black |
| Mounting Orientation | Vertical |
| Mount Type | Rack-mountable |
| Rack Height | 0U |
| Cord Length | 10 ft (3.05 m) |
| Height | 70.50" (1790.70 mm) |
| Width | 2.20" (55.88 mm) |
| Depth | 2.20" (55.88 mm) |
| Weight (Approximate) | 19.40 lb (8799.69 g) |
| Miscellaneous | |
| Country of Origin | Philippines |
| Environmentally Friendly | Yes |
| Environmental Compliance | Restriction of Hazardous Substances (RoHS) |
| Warranty | |
| Limited Warranty | 3 Year |
User Manual
FAQ
What is the difference between switched and metered-by-outlet functionality in this PDU?
This PDU combines both capabilities: switched functionality allows you to remotely turn individual outlets on or off, while metered-by-outlet provides real-time power consumption monitoring at each specific outlet. This combination enables complete power management, from remote rebooting of equipment to tracking exact energy usage per device for capacity planning and efficiency optimization.
What types of equipment can I connect to the different outlet types on this PDU?
The 24 IEC C13 outlets are suitable for standard servers, networking equipment, and devices with C14 inlets typically drawing up to 10A. The 6 IEC C19 outlets support higher-power equipment such as blade server chassis, large storage arrays, and UPS systems with C20 inlets, capable of handling up to 16A. This combination accommodates diverse data center equipment while maximizing outlet utilization.
How does the 0U vertical mounting work, and what are the space benefits?
The PDU83107 mounts vertically along the side or rear of a standard 19-inch equipment rack, consuming zero horizontal rack units (0U). This design preserves all horizontal rack space for servers, switches, and other equipment while still providing power distribution to the entire rack. The vertical orientation also improves airflow compared to horizontal PDUs that can obstruct front-to-back cooling paths.
What management protocols does this PDU support for remote monitoring and control?
The PDU supports comprehensive management protocols including SNMPv1/v3 for monitoring, HTTP/HTTPS for web-based configuration, SSH and Telnet for command-line access, and LDAP(S) for authentication integration. It also supports alert notifications via email, SMS, and SNMP traps, enabling proactive response to power events without requiring physical access to the equipment.
What is the input power requirement for this 3-phase PDU?
This PDU requires a 3-phase power source with a voltage range of 200-240V AC and a 50A circuit. The nominal input voltage is 230V AC. The unit uses a Hubbell CS8365C connector, which is a common 3-phase locking connector type for data center power distribution. Proper installation should be performed by qualified electricians familiar with 3-phase power systems.
How does the outlet-level metering help with data center power management?
Outlet-level metering provides precise power consumption data for each connected device, enabling identification of inefficient equipment, accurate capacity planning, and verification of power usage effectiveness (PUE) metrics. This granular data helps optimize rack density, balance loads across phases, identify underutilized equipment for consolidation, and provide detailed power usage reporting for billing or sustainability initiatives.