CyberPower PR2000RTXL2UC Smart App Sinewave UPS - 2000VA/2000W - 120V - 2U Rack/Tower - Sine Wave Output - 8 Outlets - LCD Display
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Product Overview
The CyberPower PR2000RTXL2UC Smart App Sinewave UPS delivers reliable backup power protection for critical business infrastructure. This line-interactive UPS system provides 2000VA/2000W of pure sine wave output power, ensuring compatibility with sensitive electronic equipment including servers, storage devices, and network hardware.
Engineered for both rack and tower deployment, this 2U form factor unit offers flexible installation options for data centers, server rooms, and network closets. The system features automatic voltage regulation (AVR) to correct minor power fluctuations without switching to battery power, extending runtime and reducing wear on internal components.
With eight NEMA 5-20R outlets providing both battery backup and surge protection, the PR2000RTXL2UC supports multiple devices simultaneously. The integrated LCD display offers real-time status monitoring, while comprehensive network management capabilities enable remote monitoring and control through SNMP, HTTP, and optional relay card interfaces.
Technical Overview
The CyberPower PR2000RTXL2UC employs a line-interactive topology with pure sine wave output, delivering clean power that matches utility-grade electricity for sensitive server and network equipment. This UPS accepts 120V AC input with a wide voltage range of 70-155V AC, providing robust protection against brownouts and overvoltage conditions without unnecessary battery drain. The system features automatic voltage regulation (AVR) to correct minor fluctuations, ensuring stable output and extending battery life.
Power conversion occurs with a minimal transfer time of 11 milliseconds, ensuring seamless transition to battery power during outages. The unit maintains output voltage within a 100-125V AC range with precise frequency regulation at 50/60Hz, compatible with international power standards. With an output power factor of 1, it delivers the full 2000 watts of real power, making it highly efficient for modern hardware with active power factor correction.
The UPS includes comprehensive protection features such as EMI/RFI noise filtering, a 2430 joule surge energy rating, and circuit breaker overload protection. Its GreenPower UPS bypass technology enhances energy savings by routing power directly during stable conditions, reducing wear and operational costs.
Key Product Advantages
The PR2000RTXL2UC combines enterprise-grade power protection with practical management features for business environments. The hot-swappable battery design allows for maintenance without system downtime, while the replaceable lead-acid batteries provide reliable energy storage with 9000mAh capacity per cell.
Advanced Power Management
Integrated PowerPanel Business Edition software enables comprehensive monitoring, configuration, and automated shutdown procedures for connected equipment.
- Remote monitoring via SNMP/HTTP
- EPO (Emergency Power Off) port
- USB HID compliant for direct computer communication
Enhanced Protection Features
Multiple layers of protection safeguard connected equipment from various power disturbances.
- 2430 joule surge energy rating
- Circuit breaker overload protection
- GreenPower UPS bypass technology for energy savings
Deployment / Use Cases
This UPS system is engineered for business-critical applications where uninterrupted power is essential. The 2000VA capacity and pure sine wave output make it ideal for protecting sensitive server hardware, network equipment, and telecommunications infrastructure.
The rack/tower convertible design provides installation flexibility for diverse environments. In data center applications, the 2U rack-mount configuration optimizes space utilization, while tower mode suits smaller server rooms or network closets where rack infrastructure may be limited.
Server Room Protection
Provides backup power for rack-mounted servers, storage arrays, and network switches during utility outages, allowing for graceful shutdown or continued operation.
- Supports multiple server configurations
- Compatible with virtualization platforms
- Integrates with existing management systems
Network Infrastructure Support
Protects VoIP systems, routers, switches, and other network equipment from power disturbances that can cause service interruptions.
- Maintains network uptime during brownouts
- Protects against data corruption
- Supports remote management capabilities
Physical Profile
The PR2000RTXL2UC features a black enclosure with dimensions optimized for standard 19-inch rack installations. Measuring 3.4 inches (2U) in height, 17.1 inches in width, and 19.7 inches in depth, the unit fits standard server racks while providing adequate ventilation for thermal management.
Weighing 74.5 pounds, the UPS includes integrated rack mounting hardware and can be configured for tower use with optional feet. The front panel LCD display provides clear status information, while LED indicators offer at-a-glance monitoring of power conditions and system status.
- Width
- 17.10" (434.34 mm)
- Depth
- 19.70" (500.38 mm)
- Height
- 3.40" (86.36 mm)
- Weight
- 57.5 dB(A)
- Length
- 10 ft (3.05 m)
Highlights
- 2000VA/2000W pure sine wave output power
- Line-interactive topology with AVR correction
- 2U rack/tower convertible form factor
- 8 NEMA 5-20R outlets with battery backup
- Hot-swappable, replaceable lead-acid batteries
- 4.3 minutes runtime at full load (12.2 minutes at half load)
- LCD display with comprehensive status monitoring
- Network management via SNMP, HTTP, and relay card
- 3-year warranty with lifetime connected equipment guarantee
- ENERGY STAR certified for energy efficiency
Specifications
| Specifications | |
|---|---|
| Manufacturer | CyberPower Systems, Inc |
| Manufacturer Part Number | PR2000RTXL2UC |
| Brand Name | CyberPower |
| Product Line | Smart App Sinewave |
| Product Model | PR2000RTXL2UC |
| Product Name | PR2000RTXL2UC Smart App Sinewave UPS Systems |
| Product Type | Line-interactive UPS |
| Technical Information | |
| AVR | Yes |
| Plug/Connector Type | NEMA 5-20P,NEMA L5-20P,NEMA 5-15P |
| Receptacle Type | NEMA 5-20R |
| Receptacle Detail | 8 x NEMA 5-20R |
| Number of Battery & Surge Outlets | 8 |
| Number of Critical Load Outlets | 4 |
| Overload Protection | Yes |
| Cord Length | 10 ft (3.05 m) |
| Transfer Time | 11 ms |
| EMI/RFI Noise Filter | Yes |
| Energy Saving | GreenPower UPS™ Bypass Technology |
| Application/Usage | Server,Storage Device,VoIP,Network Device,Telecommunication,Equipment,Corporate |
| Surge Suppression | Yes |
| Features | Audible Alarm |
| Power Description | |
| Load Capacity (VA) | 2 kVA |
| Load Capacity (Watt) | 2 kW |
| Input Voltage | 120 V AC |
| Input Voltage Range | 70 V AC - 155 V AC,100 V AC - 125 V AC,75 V AC - 149 V AC |
| Output Voltage | 100 V AC,110 V AC,120 V AC,125 V AC |
| Input Frequency | 47 Hz,63 Hz |
| Output Frequency | 50 Hz,60 Hz |
| Waveform Type | Sine Wave |
| Surge Energy Rating | 2430 J |
| Circuit Breaker | Yes |
| Output Power Factor | 1 |
| Display & Graphics | |
| Display | LCD |
| Management | |
| Network Management | Relay-MS Card,Dry Contact,SNMP/HTTP Remote Monitoring |
| Alarm | Battery Mode,Low Battery,Overload,Over-charge,Fault |
| Controls/Indicators | |
| Status Indicators | LED Indicators Power On Line Mode Battery Mode Fault |
| Interfaces/Ports | |
| Serial Port | Yes |
| USB | Yes |
| EPO Port | Yes |
| USB (HID Compliant) Port | Yes |
| Battery Information | |
| Number of Batteries | 4 |
| Battery Characteristics | Sealed |
| Battery Chemistry | Lead Acid |
| Battery Size | 12V |
| Battery Capacity | 9000 mAh |
| Backup/Run Time (Full Load) | 4.30 Minute |
| Backup/Run Time (Half Load) | 12.20 Minute |
| Hot Swappable | Yes |
| Typical Battery Recharge Time | 3 Hour |
| Replaceable Battery | Yes |
| Environmental Conditions | |
| Maximum Operating Elevation | 9842.52 ft (3000000 mm) |
| Maximum Storage Elevation | 49209.32 ft (14999000 mm) |
| Storage Temperature | 5°F (-15°C) - 113°F (45°C) |
| Operating Humidity | 95% |
| Storage Relative Humidity | 95% |
| Minimum Operating Temperature | 32°F (0°C) |
| Maximum Operating Temperature | 104°F (40°C) |
| Sound Emission (A-Weighted) | 57.5 dB(A) |
| Thermal Dissipation | 130 BTU/h |
| Physical Characteristics | |
| Product Color | Black |
| Height | 3.40" (86.36 mm) |
| Width | 17.10" (434.34 mm) |
| Depth | 19.70" (500.38 mm) |
| Length | 24.25" (615.95 mm) |
| Rack Height | 2U |
| Form Factor | Rack/Tower |
| Weight (Approximate) | 74.50 lb (33792.63 g) |
| Miscellaneous | |
| Energy Star | Yes |
| Country of Origin | China |
| Environmentally Friendly | Yes |
| Environmental Compliance | Restriction of Hazardous Substances (RoHS) |
| Warranty | |
| Limited Warranty | 3 Year |
| Additional Warranty Information | Connected Equipment Guarantee: Lifetime |
User Manual
FAQ
What is the power capacity of this UPS?
The CyberPower PR2000RTXL2UC delivers 2000VA/2000W of pure sine wave output power, providing sufficient capacity to protect critical server, storage, and network equipment during power interruptions.
What runtime can I expect at different load levels?
At full 2000W load, the UPS provides approximately 4.3 minutes of backup runtime. At half load (1000W), runtime extends to about 12.2 minutes, allowing time for graceful shutdowns or continued operation during brief outages.
How many devices can this UPS support?
The unit features eight NEMA 5-20R outlets, all providing both battery backup and surge protection. Four of these are designated as critical load outlets, offering enhanced protection for essential equipment.
What input and output voltages does this UPS support?
The UPS accepts 120V AC input with a wide range of 70-155V AC, automatically correcting voltage fluctuations. Output is regulated to 100-125V AC pure sine wave, ensuring clean power compatible with sensitive electronic equipment.
Can this UPS be installed in both rack and tower configurations?
Yes, the PR2000RTXL2UC features a convertible 2U rack/tower design. It includes integrated rack mounting hardware for standard 19-inch server racks and can be configured for tower use with optional feet, providing installation flexibility for different environments.
What management and monitoring options are available?
The UPS includes comprehensive management capabilities with USB, serial, and EPO ports, plus support for SNMP/HTTP remote monitoring via optional relay cards. The front-panel LCD display provides real-time status information, and PowerPanel Business Edition software enables automated shutdown procedures and remote configuration.