Shipping included*
Exclusions
Additional shipping fees may apply in rare circumstances for deliveries outside standard service areas. In most cases, this only potentially affects shipments to the Northwest Territories and Yukon, as well as certain heavy or oversized items.
Eaton EVMI8365X G4 Metered PDU - 42 Outlets - 14. 4 kVA - 24x C13 - 18x C39 - 230V AC - Rack-Mountable - SNMP
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This metered PDU operates on a three-phase power system with a 230V AC input and 208V AC output, handling up to 50A input current. The CS8365 plug connector ensures secure power input, while individual circuit breakers protect each outlet group from overloads.
Network connectivity is provided via an RJ-45 port for the embedded SNMP management card, allowing integration into existing network management systems. The unit includes a 10 ft (3.05 m) power cord for flexible placement within the rack environment.
This section brings together practical product details such as PDU Type, Phase, Plug/Connector Type, Input Voltage, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
A strong technical summary explains how the product's interfaces, hardware profile, and operating characteristics work together in real deployment. Buyers often need this context to confirm compatibility with existing devices, expected performance in daily use, and whether installation will be straightforward for IT staff or end users.
Key Product Advantages
The Eaton G4 PDU combines high outlet density with advanced monitoring features in a space-efficient vertical form factor. Its toolless button-mount design allows quick installation without additional hardware, while the 0U rack height preserves valuable rack space for other equipment.
These strengths make the product easier to deploy and manage in real environments, especially where reliability, usability, and day-to-day operational continuity matter. Notable benefits include Precise Power Monitoring, Remote Management Capability.
Precise Power Monitoring
The front-panel LCD display shows real-time voltage, current, and power utilization, helping administrators prevent overloads and optimize power distribution across connected equipment.
Remote Management Capability
SNMP network management enables remote monitoring, configuration, and alerting through standard network protocols, reducing the need for physical access to the data center rack.
Deployment / Use Cases
This PDU is specifically designed for IT equipment deployment in controlled environments like data centers, server rooms, and network operation centers. The combination of metered monitoring, SNMP management, and high outlet count makes it suitable for organizations requiring detailed power usage insights and remote infrastructure management.
The vertical mounting orientation and compact 2.56" width allow installation in standard 19" racks without occupying valuable equipment U-space, making it particularly valuable in densely packed rack configurations.
Data Center Power Distribution
Ideal for server racks, network cabinets, and storage arrays in enterprise data centers where multiple devices require reliable, monitored power with remote management capabilities.
High-Density IT Environments
Supports environments with numerous servers, switches, and other rack-mounted equipment that benefit from the 42-outlet capacity and three-phase power delivery.
Physical Profile
The PDU features a vertical form factor with dimensions of 72" height × 2.56" width × 2.05" depth (1828.80 × 65.02 × 52.07 mm), designed to mount vertically in standard 19" equipment racks. With a weight of approximately 25.35 lb (11498.57 g) and a black finish, it maintains a professional appearance in data center environments.
The toolless button-mount system simplifies installation, while the 0U rack height designation means it doesn't consume any rack unit space, preserving all U-space for servers, switches, and other equipment. The unit operates within a temperature range of 32°F to 140°F (0°C to 60°C), suitable for typical data center conditions.
- Width
- 2.56" (65.02 mm)
- Depth
- 2.05" (52.07 mm)
- Height
- 0U
- Weight
- 25.35 lb (11498.57 g)
- Length
- 10 ft (3.05 m)
What's in the Box
The package includes the G4 EVMI8365X 42-Outlets PDU unit along with mounting buttons for secure rack installation.
Package contents include G4 EVMI8365X 42-Outlets PDU Mounting Buttons, G4 EVMI8365X 42-Outlets PDU. These included items support setup, installation, and immediate deployment without needing to source the core bundled accessories separately.
Highlights
- 42 total outlets: 24 IEC C13 and 18 IEC C39 receptacles
- 14.4 kVA / 14.4 kW three-phase power capacity
- 230V AC input with 208V AC output voltage
- SNMP network management with RJ-45 connectivity
- Front-panel LCD display for real-time power monitoring
- Vertical rack-mount design with 0U footprint
- Toolless button-mount installation system
- Circuit breaker protection for overload safety
- 10 ft (3.05 m) power cord included
- 3-year limited warranty
Specifications
| Specifications | |
|---|---|
| Manufacturer | Eaton Corporation |
| Manufacturer Part Number | EVMI8365X |
| Brand Name | Eaton |
| Product Series | G4 |
| Product Model | EVMI8365X |
| Product Name | G4 EVMI8365X 42-Outlets PDU |
| Product Type | PDU |
| Technical Information | |
| PDU Type | Metered |
| Phase | Three Phase |
| Plug/Connector Type | CS8365 |
| Receptacle Type | IEC 60320 C13,IEC 60320 C39 |
| Receptacle Detail | 24 x IEC 60320 C13,18 x IEC 60320 C39 |
| Protection Type | Circuit Breaker |
| Features | LCD Display |
| Power Description | |
| Input Voltage | 230 V AC |
| Output Voltage | 208 V AC |
| Power Rating (VA) | 14.40 kVA |
| Power Rating (Watt) | 14.40 kW |
| Input Current | 50 A |
| Management | |
| Management | SNMP Network Management Card |
| Interfaces/Ports | |
| Network (RJ-45) | Yes |
| Physical Characteristics | |
| Color Family | Black |
| Product Color | Black |
| Mounting Orientation | Vertical/Toolless |
| Mount Type | Rack-mountable,Button Mount |
| Form Factor | Vertical |
| Rack Height | 0U |
| Cord Length | 10 ft (3.05 m) |
| Height | 72" (1828.80 mm) |
| Width | 2.56" (65.02 mm) |
| Depth | 2.05" (52.07 mm) |
| Weight (Approximate) | 25.35 lb (11498.57 g) |
| Environmental Conditions | |
| Minimum Operating Temperature | 32°F (0°C) |
| Maximum Operating Temperature | 140°F (60°C) |
| Miscellaneous | |
| Package Contents | G4 EVMI8365X 42-Outlets PDU Mounting Buttons |
| Application/Usage | Data Center,IT Equipment |
| Country of Origin | Philippines |
| Environmentally Friendly | Yes |
| Environmental Compliance | Restriction of Hazardous Substances (RoHS) |
| Warranty | |
| Limited Warranty | 3 Year |
User Manual
FAQ
What is the total power capacity of this Eaton PDU?
The Eaton G4 EVMI8365X PDU delivers 14.4 kVA (14.4 kW) of three-phase power capacity with a 50A input current. This substantial capacity supports multiple servers, networking equipment, and storage devices in high-density rack environments while providing headroom for future expansion.
How many outlets does this PDU have and what types are they?
This PDU features 42 total outlets: 24 IEC 60320 C13 receptacles and 18 IEC 60320 C39 receptacles. This combination accommodates a wide range of IT equipment, from servers and switches to storage devices and other rack-mounted hardware requiring different power connector types.
What management features does this metered PDU include?
The PDU includes an SNMP network management card with RJ-45 connectivity for remote monitoring and control. Additionally, it features a front-panel LCD display that shows real-time power metrics including voltage, current, and power utilization, enabling both local and remote power management.
How is this PDU mounted in a rack?
This PDU uses a vertical rack-mount design with a toolless button-mount system for easy installation. It has a 0U rack height, meaning it mounts vertically without consuming any rack unit space, preserving all U-space for servers, switches, and other equipment in the rack.
What input voltage does this PDU require?
The PDU requires a 230V AC three-phase power input and delivers 208V AC output to connected equipment. This voltage configuration is standard for many data center and enterprise IT environments, supporting efficient power distribution to multiple devices.
What protection features does this PDU offer?
The PDU includes circuit breaker protection to prevent overloads and ensure safe operation. The metered functionality with LCD display helps administrators monitor power usage in real time, allowing proactive management to avoid potential overload situations before they occur.
What power capacity is listed for this UPS?
The listed power specification is 14.40 kVA, which helps position the unit for the right load level and installation role.
What voltage details are listed?
The listed power specification is 230 V AC, which helps position the unit for the right load level and installation role.