Shipping included*
Exclusions
Additional shipping fees may apply in rare circumstances for deliveries outside standard service areas. In most cases, this only potentially affects shipments to the Northwest Territories and Yukon, as well as certain heavy or oversized items.
Eaton 9EA02GG05032003 93E 20 kVA Double Conversion Online UPS - Dual Feed - Internal Batteries - MS Network/ModBus Card - 21 Minute Runtime - 208/220
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This Eaton UPS operates on a double conversion online topology, providing pure sine wave output and zero transfer time during power transitions. It accepts input voltages of 208 V AC and 220 V AC, with matching output voltages to ensure compatibility with standard North American power systems. The input and output frequencies are fixed at 60 Hz, maintaining consistent power quality for sensitive electronic loads.
The internal battery system uses maintenance-free sealed lead-acid chemistry, eliminating the need for regular fluid checks and reducing maintenance overhead. The serial port facilitates direct communication with monitoring systems, while the integrated MS Network/ModBus card extends connectivity for network-based management. Overload protection is included to prevent damage from excessive power demands, and the unit is designed with environmentally friendly materials.
Key Product Advantages
This Eaton UPS combines high-capacity power protection with advanced features to meet the demands of modern IT and industrial environments. Its double conversion technology ensures clean, stable power output, while the dual-feed capability provides an extra layer of reliability. The internal batteries and network management card make it a complete, ready-to-deploy solution for organizations prioritizing uptime and operational efficiency.
Dual Feed Reliability
The dual-feed design enhances power redundancy, allowing connection to two separate power sources for increased uptime and fault tolerance in critical applications.
Integrated Management
With the MS Network/ModBus card, this UPS enables remote monitoring, configuration, and alerts, simplifying administration and reducing onsite intervention needs.
Maintenance-Free Operation
Sealed lead-acid batteries require no routine maintenance, lowering total cost of ownership and ensuring consistent performance without frequent servicing.
Deployment / Use Cases
The Eaton 20 kVA UPS is designed for deployments where power quality and availability are non-negotiable. Its 20 kVA capacity supports medium to large loads, making it a fit for centralized power protection in commercial buildings, healthcare facilities, and telecommunications hubs.
In scenarios with dual power feeds, this unit can leverage redundant sources to maximize resilience. The 21-minute runtime at full load provides sufficient time for graceful shutdowns or generator startup, while the network management capabilities allow IT teams to monitor power status from anywhere. Its robust construction and standard voltage compatibility ensure easy integration into existing infrastructure.
Data Center Power Backup
Ideal for server racks, networking equipment, and storage systems in data centers, where continuous power is essential to prevent data loss and downtime during outages.
Industrial Control Systems
Suitable for manufacturing plants and process control environments, protecting PLCs, SCADA systems, and other critical machinery from power disturbances that could disrupt operations.
Physical Profile
This UPS has a substantial footprint designed for floor or rack mounting in dedicated equipment rooms. It measures 53.50 inches in height, 20.90 inches in width, and 31.50 inches in depth, with an approximate weight of 1058 pounds. The dimensions accommodate standard rack configurations while providing ample internal space for batteries and cooling. The heavy-duty construction ensures durability in demanding environments, and the design facilitates proper airflow to maintain optimal operating temperatures during extended use.
- Width
- 20.90" (530.86 mm)
- Depth
- 31.50" (800.10 mm)
- Height
- 53.50" (1358.90 mm)
- Weight
- 1058 lb (479900.73 g)
Highlights
- 20 kVA double conversion online UPS for critical power protection
- Dual-feed design enhances power redundancy and uptime
- Internal maintenance-free sealed lead-acid batteries included
- MS Network/ModBus card enables remote monitoring and management
- 21-minute runtime at full load for graceful shutdowns
- 208 V AC and 220 V AC input/output voltage compatibility
- Overload protection safeguards connected equipment
- Environmentally friendly construction with reduced maintenance needs
- Serial port for direct communication with monitoring systems
- Substantial build with dimensions suited for rack or floor installation
Specifications
| Specifications | |
|---|---|
| Manufacturer | Eaton Corporation |
| Manufacturer Part Number | 9EA02GG05032003 |
| Brand Name | Eaton |
| Product Model | 93E |
| Product Name | 20 kVA UPS Dual Feed with Internal Batteries & MS Network/ModBus Card |
| Product Type | Double Conversion Online UPS |
| Technical Information | |
| Overload Protection | Yes |
| Power Description | |
| Load Capacity (VA) | 20 kVA |
| Input Voltage | 208 V AC,220 V AC |
| Output Voltage | 208 V AC,220 V AC |
| Input Frequency | 60 Hz |
| Output Frequency | 60 Hz |
| Interfaces/Ports | |
| Serial Port | Yes |
| Battery Information | |
| Battery Characteristics | Maintenance-free/Sealed |
| Battery Chemistry | Lead Acid |
| Backup/Run Time (Full Load) | 21 Minute |
| Physical Characteristics | |
| Height | 53.50" (1358.90 mm) |
| Width | 20.90" (530.86 mm) |
| Depth | 31.50" (800.10 mm) |
| Weight (Approximate) | 1058 lb (479900.73 g) |
| Miscellaneous | |
| Environmentally Friendly | Yes |
User Manual
FAQ
What is the power capacity of this Eaton UPS?
This Eaton UPS has a load capacity of 20 kVA, making it suitable for protecting medium to large critical loads such as server racks, networking gear, or industrial control systems. The double conversion online topology ensures clean, stable power output regardless of input conditions.
How long does the battery backup last at full load?
At full load, the internal batteries provide a backup runtime of 21 minutes. This duration allows sufficient time for connected equipment to perform graceful shutdowns or for auxiliary power sources like generators to start up, minimizing disruption during power outages.
What input and output voltages does this UPS support?
This UPS supports input voltages of 208 V AC and 220 V AC, with matching output voltages. This compatibility aligns with standard North American power systems, ensuring seamless integration into existing electrical infrastructure without requiring voltage converters.
Does this UPS include remote management capabilities?
Yes, it includes an MS Network/ModBus card that enables remote monitoring and management over a network. This allows IT administrators to check status, configure settings, and receive alerts from anywhere, improving proactive maintenance and reducing onsite visits.
What type of batteries are used, and do they require maintenance?
The UPS uses maintenance-free sealed lead-acid batteries, which require no routine fluid checks or topping up. This design reduces total cost of ownership and ensures reliable performance without frequent servicing, making it ideal for installations where accessibility is limited.
Is this UPS suitable for rack mounting?
Yes, with dimensions of 53.50 inches in height, 20.90 inches in width, and 31.50 inches in depth, this UPS is designed for rack or floor mounting in equipment rooms. Its substantial build and weight of approximately 1058 pounds ensure stability, but proper rack reinforcement and floor loading should be verified before installation.
What power capacity is listed for this UPS?
The listed power specification is 20 kVA, which helps position the unit for the right load level and installation role.
What voltage details are listed?
The listed power specification is 208 V AC,220 V AC, which helps position the unit for the right load level and installation role.