APC by Schneider Electric APDU10350ME NetShelter Rack PDU Advanced - Metered - 3-Phase - 17. 3kW/17. 3kVA - 48 Outlets - IEC 60309 30A - 0U Vertical
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This three-phase PDU accepts input voltages of 415V or 480V with a 30A IEC 60309 connector, delivering a stable 240V AC output. The 17.3kW/17.3kVA rating ensures it can handle substantial aggregated loads from servers, storage, and networking gear. Outlet configuration includes 24 IEC C13/C15/C19/C21 receptacles and 24 IEC C13/C15 receptacles, providing flexibility for both high- and standard-power devices.
Network connectivity via RJ-45 enables integration into management systems, supporting protocols for real-time monitoring of volts, amps, kW, and kWh. The unit operates within a temperature range of 23°F to 140°F (-5°C to 60°C) and is backed by a 3-year warranty from APC.
This section brings together practical product details such as PDU Type, Phase, Plug/Connector Type, Input Voltage, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
Key Product Advantages
The APC NetShelter Advanced Metered PDU combines high power capacity with intelligent monitoring in a space-saving vertical form factor. Its design prioritizes both deployment flexibility and operational insight for modern data centers.
High-Density Power Distribution
With 48 outlets and 17.3kW capacity, this PDU consolidates power distribution for multiple racks of equipment, reducing cable clutter and simplifying power infrastructure.
- 48 IEC outlets (24 C13/C15/C19/C21 + 24 C13/C15)
- 17.3kW/17.3kVA total capacity
- Supports mixed device loads
Active Power Monitoring
The metered functionality provides real-time visibility into power usage at the PDU level, helping to optimize load balancing, prevent overloads, and track energy efficiency.
- Measures volts, amps, kW, kWh
- Interactive LCD display for local viewing
- Network-enabled for remote monitoring
Rack-Optimized Design
The vertical, 0U mounting orientation saves valuable rack space for IT equipment, while the slim 2.2-inch width and standard rack depth ensure compatibility with most enclosures.
- Vertical mounting in 0U space
- Dimensions: 70.08"H x 2.20"W x 2.95"D
- Black finish blends with rack aesthetics
Deployment / Use Cases
This PDU is engineered for environments where power distribution needs to be both high-capacity and intelligently managed. Its three-phase input and metered capabilities make it suitable for larger installations where power usage visibility and reliability are paramount.
In data centers, it can power a full rack of servers, storage arrays, and networking switches while providing the monitoring needed for capacity planning and efficiency reporting. For server rooms in enterprises or colocation facilities, it offers a scalable solution that supports growth without requiring frequent power infrastructure upgrades.
Data Center Power Distribution
Deploy in standard 19-inch racks to distribute three-phase power to high-density server and storage deployments, with monitoring integrated into DCIM tools.
Server Room Consolidation
Use to replace multiple lower-capacity PDUs, reducing complexity and improving power management for mid-size to large IT environments.
Physical Profile
The PDU features a vertical rack-mount design with a 0U height, meaning it installs in the vertical space at the side of the rack without consuming horizontal U positions. Its dimensions are 70.08 inches in height, 2.20 inches in width, and 2.95 inches in depth, with a weight of approximately 18.52 pounds. The black finish ensures a professional appearance that matches typical rack equipment, and the 5.9-foot power cord provides flexibility in connecting to upstream power sources.
- Width
- 2.20" (56 mm)
- Depth
- 2.95" (75 mm)
- Height
- 0U
- Weight
- 18.52 lb (8400.53 g)
- Length
- 5.9 ft (1.80 m)
Highlights
- 17.3kW/17.3kVA three-phase power capacity
- 48 IEC outlets (24 C13/C15/C19/C21 + 24 C13/C15)
- Metered with active power measurement (volts, amps, kW, kWh)
- Network management capability via RJ-45
- Vertical, 0U rack-mount form factor
- Input: 415V/480V, 30A IEC 60309 connector
- Output: 240V AC
- 3-year APC warranty
- TAA compliant and RoHS environmental compliance
- Operating temperature range: 23°F to 140°F (-5°C to 60°C)
Specifications
| Specifications | |
|---|---|
| Manufacturer | Schneider Electric SA |
| Manufacturer Part Number | APDU10350ME |
| Brand Name | APC by Schneider Electric |
| Product Line | NetShelter |
| Product Name | NetShelter 48-Outlets PDU |
| Packaged Quantity | 1 |
| Product Type | PDU |
| Technical Information | |
| PDU Type | Metered |
| Phase | Three Phase |
| Plug/Connector Type | IEC 60309 30A 3P+N+PE |
| Receptacle Type | IEC 60320 C13/C15/C19/C21,IEC 60320 C13/C15 |
| Receptacle Detail | 24 x IEC 60320 C13/C15/C19/C21,24 x IEC 60320 C13/C15 |
| Power Description | |
| Input Voltage | 415 V,480 V |
| Input Voltage Range | 200 V AC - 240 V AC,346 V AC - 415 V AC |
| Output Voltage | 240 V AC |
| Power Rating (VA) | 17.30 kVA |
| Power Rating (Watt) | 17.30 kW |
| Input Current | 30 A |
| Interfaces/Ports | |
| Network (RJ-45) | Yes |
| Physical Characteristics | |
| Color Family | Black |
| Product Color | Black |
| Mounting Orientation | Vertical |
| Form Factor | Rack |
| Rack Height | 0U |
| Cord Length | 5.9 ft (1.80 m) |
| Height | 70.08" (1780 mm) |
| Width | 2.20" (56 mm) |
| Depth | 2.95" (75 mm) |
| Weight (Approximate) | 18.52 lb (8400.53 g) |
| Environmental Conditions | |
| Minimum Operating Temperature | 23°F (-5°C) |
| Maximum Operating Temperature | 140°F (60°C) |
| Minimum Storage Temperature | -13°F (-25°C) |
| Maximum Storage Temperature | 149°F (65°C) |
| Miscellaneous | |
| Country of Origin | China |
| TAA Compliant | Yes |
| Environmentally Friendly | Yes |
| Environmental Compliance | Restriction of Hazardous Substances (RoHS) |
| Warranty | |
| Limited Warranty | 3 Year |
User Manual
FAQ
What is the power capacity of this APC NetShelter PDU?
This PDU has a power rating of 17.30 kVA and 17.30 kW, making it suitable for high-density rack deployments. It can handle substantial aggregated loads from servers, storage, and networking equipment in a three-phase power configuration.
How many outlets does this PDU have and what types are they?
It provides 48 IEC outlets: 24 are IEC C13/C15/C19/C21 receptacles for higher-power devices, and 24 are IEC C13/C15 receptacles for standard-power equipment. This mix supports a wide range of IT devices within a single rack.
What does 'metered' mean for this rack PDU?
Metered indicates the PDU can measure and display active power consumption at the unit level. It monitors parameters like volts, amps, kW, and kWh, providing visibility into power usage for load management and efficiency tracking without individual outlet metering.
How is this PDU mounted in a rack?
It uses a vertical, 0U rack-mount form factor. This means it installs in the vertical space at the side of a standard 19-inch rack, consuming zero horizontal U positions, which preserves space for IT equipment. The mounting orientation is vertical.
What input voltage and connector does this PDU require?
The PDU accepts three-phase input voltages of 415V or 480V through an IEC 60309 30A 3P+N+PE connector. It has an input voltage range of 200-240V AC and 346-415V AC, delivering a stable 240V AC output to connected devices.
Does this PDU support network management?
Yes, it includes an RJ-45 network port for full-featured network management capability. This allows remote monitoring and integration into data center management systems, enabling real-time tracking of power metrics and alerts.
What power capacity is listed for this UPS?
The listed power specification is 17.30 kVA, which helps position the unit for the right load level and installation role.
What voltage details are listed?
The listed power specification is 415 V,480 V, which helps position the unit for the right load level and installation role.