Shipping included*
Exclusions
Additional shipping fees may apply in rare circumstances for deliveries outside standard service areas. In most cases, this only potentially affects shipments to the Northwest Territories and Yukon, as well as certain heavy or oversized items.
Server Technology C2L24SP-YCLN5D6 PRO2 Smart PDU - 24 Outlets - 18 C13 - 6 CX - 8. 6 kW - 230V AC Input - 2U Rack-Mount - Monitored
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This monitored PDU operates on a three-phase electrical system with a 30 A input current and 60 Hz frequency. It incorporates branch circuit protection through UL489-rated magnetic-hydraulic circuit breakers or UL248 fuses, meeting UL and IEC 60950-1 safety standards. The locking receptacles use P-Lock compatibility for secure power cord retention, and the LED display auto-flips to show current per phase, simplifying load balancing in high-density cabinets.
Network management is robust, supporting HTTP/HTTPS with TLSv1.2, SSHv2, Telnet, SNMPv2c/v3, IPv4/IPv6, LDAPv3/LDAPS, TACACS+, RADIUS, and FTP/SFTP protocols. This allows remote access to power data, temperature, and humidity measurements via web, CLI, or SNMP interfaces. The unit’s star multi-linking capability enables connection to up to three PRO2 Smart Link PDUs using one IP address, providing network access redundancy without daisy-chain risks.
Key Product Advantages
The PRO2 Smart PDU offers significant advantages for modern data center power management. Its hybrid CX outlets accommodate both C20 and C14 plugs, providing future-ready flexibility, while high-retention locking outlets ensure secure connections. The hot-swap network card maintains network access during primary power loss, with backup power supplied by the primary link unit, enhancing reliability in critical setups.
Advanced Monitoring
Per-inlet power sensing meets ANSI C12.1 for billing-grade accuracy, monitoring current, voltage, power factor, and energy. Branch current monitoring tracks each breaker branch, sending SNMP alerts and emails on high usage to prevent circuit trips.
- Billing-grade accuracy
- SNMP alerts for high usage
- Prevents circuit trips
Environmental Integration
Supports two external 10-foot temperature and humidity probes per unit, enabling SNMP-based alerts and email notifications for environmental conditions. This integration helps maintain optimal operating environments for IT equipment.
- External T/H probes
- SNMP and email alerts
- Optimizes equipment conditions
Deployment / Use Cases
This PDU is ideal for data centers, server rooms, and network closets where precise power distribution and monitoring are critical. Its 2U rack-mount design fits standard cabinets, making it suitable for high-density deployments in enterprise IT environments. The alternating-phase outlets evenly distribute power phases, simplifying load balancing, reducing cord lengths, and improving airflow within racks.
Use cases include supporting server racks, storage arrays, networking equipment, and other IT infrastructure requiring reliable three-phase power. The ability to link multiple PDUs under one IP address streamlines management in redundant power feed setups, while color identification options (Blue, Red, Green, White, Yellow, Black) allow circuit designation for organized data center layouts.
Physical Profile
The PDU features a compact 2U rack-mount design with dimensions of 3.50 inches in height (88.90 mm), 17.20 inches in width (436.88 mm), and 10 inches in depth (254 mm). This form factor ensures efficient use of rack space while providing ample outlet capacity. The unit is tested for safe operation in temperatures up to 60°C, making it reliable for data center environments with elevated thermal conditions.
- Width
- 17.20" (436.88 mm)
- Depth
- 10" (254 mm)
- Height
- 2U
Highlights
- 24 total outlets: 18 IEC 60320 C13 and 6 CX hybrid receptacles for flexible plug compatibility.
- 8.6 kW power rating with 230 V AC input and 208 V AC output for robust three-phase distribution.
- Advanced monitoring with PIPS technology for billing-grade accuracy of current, voltage, and power metrics.
- Network management via HTTP/HTTPS, SSH, SNMP, LDAP, and more for remote access and control.
- Star multi-linking supports up to four power circuits under one IP address with redundancy.
- Hot-swap network card ensures continuous network access during primary power loss.
- Temperature and humidity monitoring with optional external probes for environmental oversight.
- Auto-flip LED display shows current per phase for easy load balancing and overload prevention.
- Branch circuit protection with UL489-rated breakers or UL248 fuses meets safety standards.
- 2U rack-mount design with locking P-Lock receptacles for secure installation in data centers.
Specifications
| Specifications | |
|---|---|
| Manufacturer | Server Technology, Inc |
| Manufacturer Part Number | C2L24SP-YCLN5D6 |
| Brand Name | Server Technology |
| Product Line | PRO2 |
| Product Series | Smart |
| Product Name | PRO2 Smart 24-Outlets PDU |
| Product Type | PDU |
| Technical Information | |
| PDU Type | Monitored |
| Phase | Three Phase |
| Plug/Connector Type | NEMA L21-30P |
| Receptacle Type | IEC 60320 C13,CX |
| Receptacle Detail | 18 x IEC 60320 C13,6 x CX |
| Protection Type | Branch Circuit,Circuit Protection,Fuse |
| Locking Receptacles | P-Lock |
| Features | LED Display |
| Power Description | |
| Input Voltage | 230 V AC |
| Output Voltage | 208 V AC |
| Power Rating (Watt) | 8.60 kW |
| Input Current | 30 A |
| Input Frequency | 60 Hz |
| Management | |
| Management | HTTP/HTTPS TLSv1.2 SSHv2 Telnet SNMPv2c v3 (GET, SET, Traps) IPv4 and IPv6 LDAPv3/LDAPS TACACS+ RADIUS FTP/SFTP |
| Interfaces/Ports | |
| Network (RJ-45) | Yes |
| Physical Characteristics | |
| Mount Type | Rack-mountable,Cabinet-mountable |
| Rack Height | 2U |
| Height | 3.50" (88.90 mm) |
| Width | 17.20" (436.88 mm) |
| Depth | 10" (254 mm) |
| Environmental Conditions | |
| Minimum Operating Temperature | 32°F (0°C) |
| Maximum Operating Temperature | 140°F (60°C) |
| Minimum Storage Temperature | -40°F (-40°C) |
| Maximum Storage Temperature | 185°F (85°C) |
| Minimum Operating Humidity | 8% |
| Maximum Operating Humidity | 90% |
| Miscellaneous | |
| Application/Usage | IT Equipment |
| Warranty | |
| Limited Warranty | 2 Year |
FAQ
What is the power rating of this Server Technology PDU?
This PDU has a power rating of 8.60 kW, with an input voltage of 230 V AC and output voltage of 208 V AC. It supports a 30 A input current at 60 Hz, making it suitable for high-power IT equipment in three-phase electrical systems.
How many outlets does this PDU have and what types are they?
It features 24 outlets total: 18 IEC 60320 C13 receptacles and 6 CX hybrid receptacles. The CX outlets accommodate both C20 and C14 plugs, offering flexibility for various power cords in data center environments.
What monitoring capabilities does this smart PDU offer?
The PDU includes local LED input current monitoring and PIPS technology for billing-grade accuracy of current, voltage, active power, apparent power, power factor, and energy. It supports optional temperature and humidity probes, with data accessible via web, CLI, and SNMP interfaces.
Can this PDU be mounted in a standard server rack?
Yes, it is designed for rack or cabinet mounting with a 2U height. Dimensions are 3.50 inches high, 17.20 inches wide, and 10 inches deep, fitting typical data center racks for efficient space utilization.
What network management protocols are supported?
It supports HTTP/HTTPS with TLSv1.2, SSHv2, Telnet, SNMPv2c/v3, IPv4 and IPv6, LDAPv3/LDAPS, TACACS+, RADIUS, and FTP/SFTP. This allows comprehensive remote management and monitoring through multiple interfaces.
Does this PDU include any redundancy or linking features?
Yes, it supports star multi-linking, allowing connection to up to three PRO2 Smart Link PDUs using one IP address. The hot-swap network card provides backup power to maintain network access if the primary unit loses power, enhancing reliability.
What power capacity is listed for this UPS?
The listed power specification is 8.60 kW, which helps position the unit for the right load level and installation role.
What voltage details are listed?
The listed power specification is 230 V AC, which helps position the unit for the right load level and installation role.