Shipping included*
Exclusions
Additional shipping fees may apply in rare circumstances for deliveries outside standard service areas. In most cases, this only potentially affects shipments to the Northwest Territories and Yukon, as well as certain heavy or oversized items.
Server Technology C3B36RL-DQJE0AT2 36-Outlet Basic PDU - IEC 60309 3P+G 60A 230V AC - 18x C13 - 18x CX - 0U Rack Mount
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This PDU operates with a 60 A input current at 60 Hz frequency, delivering consistent power to connected equipment. The unit incorporates multiple protection mechanisms including branch circuit, circuit breaker, and fuse protection to safeguard against overloads and electrical faults.
Environmental resilience is supported with an operating temperature range of 32°F to 140°F (0°C to 60°C) and humidity tolerance from 8% to 90%, ensuring reliable performance in typical data center conditions. The output configuration provides balanced power distribution across all outlets with locking mechanisms on key receptacles.
This section brings together practical product details such as PDU Type, Plug/Connector Type, Receptacle Type, Input Voltage, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
A strong technical summary explains how the product's interfaces, hardware profile, and operating characteristics work together in real deployment. Buyers often need this context to confirm compatibility with existing devices, expected performance in daily use, and whether installation will be straightforward for IT staff or end users.
Key Product Advantages
This PDU offers several advantages for power management in critical IT infrastructure. The high outlet count and mixed receptacle types provide flexibility for connecting diverse equipment, while the 0U mounting preserves valuable rack space for servers and networking gear.
These strengths make the product easier to deploy and manage in real environments, especially where reliability, usability, and day-to-day operational continuity matter. Notable benefits include 36-outlet capacity, Dual receptacle types (C13 and CX), RamLock locking security, 0U rack space efficiency, 17.30 kW power handling.
Deployment / Use Cases
This basic PDU is engineered for cost-effective power distribution in wiring closets, server rooms, and equipment racks. Its design makes it ideal for environments where reliable power delivery is essential but advanced monitoring features are not required.
Primary applications include data center server racks, network equipment cabinets, and IT infrastructure deployments where high-density power distribution is needed. The unit supports IT equipment, server racks, and data center installations with its robust construction and appropriate electrical ratings.
Data Center Racks
Provides centralized power distribution for multiple servers and networking devices in standard 19-inch racks.
- 0U mounting saves vertical space
- 36 outlets support high-density configurations
- Locking receptacles prevent accidental disconnections
Network Equipment Cabinets
Delivers reliable power to switches, routers, and other networking hardware in telecommunications and enterprise environments.
- Compact 2.20" width fits narrow cabinets
- Mixed C13 and CX outlets accommodate various power cords
- Circuit protection safeguards sensitive equipment
Physical Profile
The PDU features a slender profile measuring 70 inches in height, 2.20 inches in width, and 2.50 inches in depth (1778 x 55.88 x 63.50 mm), designed for vertical mounting along rack rails. The 0U rack height designation means it occupies no rack units, mounting directly to rack posts or using included button mounts for secure installation. This form factor maximizes usable rack space while providing full-length power distribution.
- Width
- 2.20" (55.88 mm)
- Depth
- 2.50" (63.50 mm)
- Height
- 0U
What's in the Box
The package includes the complete PDU unit ready for installation with all necessary mounting hardware.
Package contents include 36-Outlets PDU Standard Button Mounts, 36-Outlets PDU. These included items support setup, installation, and immediate deployment without needing to source the core bundled accessories separately.
Highlights
- 36 total outlets with 18 IEC 60320 C13 and 18 CX receptacles
- IEC 60309 3P+G 60A input connector for three-phase power
- 17.30 kW power rating handles substantial electrical loads
- 0U rack-mount design preserves valuable vertical rack space
- RamLock locking receptacles enhance connection security
- 230 V AC input voltage with 208 V AC output
- Comprehensive protection including circuit breaker and fuse
- Operating temperature range: 32°F to 140°F (0°C to 60°C)
- 2-year limited warranty for peace of mind
- Button mount included for secure rack installation
Specifications
| Specifications | |
|---|---|
| Manufacturer | Legrand Group |
| Manufacturer Part Number | C3B36RL-DQJE0AT2 |
| Brand Name | Server Technology |
| Product Name | 36-Outlets PDU |
| Product Type | PDU |
| Technical Information | |
| PDU Type | Basic |
| Plug/Connector Type | IEC 60309 3P+G 9Hr 60A |
| Receptacle Type | IEC 60320 C13,CX |
| Receptacle Detail | 18 x IEC 60320 C13,18 x CX |
| Protection Type | Branch Circuit,Circuit Breaker,Circuit Protection,Fuse |
| Locking Receptacles | RamLock Locking Outlet,HDOT Cx RamLock |
| Power Description | |
| Input Voltage | 230 V AC |
| Output Voltage | 208 V AC |
| Power Rating (Watt) | 17.30 kW |
| Input Current | 60 A |
| Input Frequency | 60 Hz |
| Physical Characteristics | |
| Mount Type | Rack-mountable,Cabinet-mountable,Button Mount |
| Rack Height | 0U |
| Height | 70" (1778 mm) |
| Width | 2.20" (55.88 mm) |
| Depth | 2.50" (63.50 mm) |
| Environmental Conditions | |
| Minimum Operating Temperature | 32°F (0°C) |
| Maximum Operating Temperature | 140°F (60°C) |
| Minimum Storage Temperature | -40°F (-40°C) |
| Maximum Storage Temperature | 185°F (85°C) |
| Minimum Operating Humidity | 8% |
| Maximum Operating Humidity | 90% |
| Miscellaneous | |
| Package Contents | 36-Outlets PDU Standard Button Mounts |
| Application/Usage | IT Equipment,Server Rack/Cabinet,Data Center |
| Warranty | |
| Limited Warranty | 2 Year |
User Manual
FAQ
What types of outlets does this PDU have?
This PDU features 36 total outlets with a mix of two receptacle types: 18 IEC 60320 C13 outlets and 18 CX outlets. This combination accommodates various power cord types commonly used in server and networking equipment, providing flexibility for different device connections within rack environments.
What is the power capacity of this PDU?
The PDU has a power rating of 17.30 kW (17,300 watts) with an input current of 60 A at 230 V AC. This substantial capacity supports high-density power requirements for multiple servers and networking devices in rack configurations, making it suitable for data center and server room applications.
How is this PDU mounted in a rack?
This PDU uses a 0U mounting configuration, meaning it mounts vertically along rack posts without consuming rack units. It includes standard button mounts for secure installation and is compatible with rack-mountable and cabinet-mountable setups. The slender 2.20-inch width allows it to fit neatly alongside equipment in standard 19-inch racks.
What protection features does this PDU include?
The PDU incorporates multiple protection mechanisms including branch circuit protection, circuit breaker, circuit protection, and fuse protection. These features help safeguard connected equipment from electrical faults, overloads, and power anomalies, providing reliable operation in critical IT environments.
What input connector type does this PDU use?
This PDU uses an IEC 60309 3P+G 9Hr 60A input connector, which is a three-phase plus ground connector rated for 60 amps. This industrial-grade connector provides secure power input for the unit's high-capacity distribution needs in data center and server room applications.
What is the operating temperature range for this PDU?
The PDU operates reliably within a temperature range of 32°F to 140°F (0°C to 60°C) and can withstand storage temperatures from -40°F to 185°F (-40°C to 85°C). It also tolerates humidity levels from 8% to 90%, making it suitable for typical data center environmental conditions.
What power capacity is listed for this UPS?
The listed power specification is 17.30 kW, which helps position the unit for the right load level and installation role.
What voltage details are listed?
The listed power specification is 230 V AC, which helps position the unit for the right load level and installation role.