CyberPower PDU31101 Monitored PDU - Single Phase 100-120V 20A - 24 Outlets - 0U Rackmount - 10 ft Cord - SNMP - 3YR
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
The PDU31101 operates on a single-phase 120V AC input at 60 Hz, with an output voltage range of 100-120V AC. It provides 20A input current, derated to 16A for continuous operation, ensuring stable power distribution to connected devices. The unit features 24 locking NEMA 5-20R receptacles, each designed to maintain secure power connections in high-vibration environments.
Network management is comprehensive, supporting IPv4 and IPv6 with protocols including SNMPv1/v3, HTTP/HTTPS, SSH, SSL/TLS, LDAP(S), RADIUS, Syslog, and CLI. This allows for automated email, SMS, and SNMP trap notifications for events such as overload conditions or environmental alerts. The PDU does not support remote outlet switching, focusing instead on monitoring and alerting capabilities.
This section brings together practical product details such as PDU Type, Phase, Plug/Connector Type, Input Voltage, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
Key Product Advantages
The CyberPower PDU31101 combines high-density power distribution with advanced monitoring in a space-saving 0U design. Its vertical mounting orientation and compact 2.20" width allow installation in tight rack spaces without sacrificing outlet count or management features.
Comprehensive Monitoring
Real-time power data via LCD display and LED indicators, with SNMP, HTTP, and SSH support for integration into network management systems.
- Automated email/SMS/SNMP notifications
- Multi-protocol support (IPv4/IPv6)
- CLI for advanced configuration
Secure Power Delivery
Overload protection safeguards connected equipment, while locking receptacles and cord retention trays prevent accidental disconnections.
- 24 NEMA 5-20R outlets
- Derated to 16A continuous
- 100-120V output range
Flexible Deployment
Rack-mountable or wall-mountable with vertical orientation, backed by a 10-foot power cord for placement flexibility in data centers or IT closets.
- 0U rack height
- Metal housing for durability
- Black finish for professional aesthetics
Deployment / Use Cases
The PDU31101 is ideal for environments requiring centralized power distribution with monitoring capabilities. Its 0U vertical design makes it suitable for full-height server racks, network cabinets, and telecommunications closets where U-space is at a premium. The 24 outlets support high-density deployments of servers, switches, and storage devices.
Common use cases include data center power distribution, server room infrastructure, and network operation centers. The SNMP and network management features allow IT teams to monitor power usage, receive alerts for overload conditions, and maintain uptime through proactive management. The wall-mount option also supports installations in equipment rooms or broadcast facilities where rack space is limited.
Data Center Racks
Deploy in 19" or 23" racks to power multiple servers and networking gear, with real-time monitoring via SNMP integration.
Network Closets
Wall-mount in IT closets to distribute power to switches, routers, and access points, with overload protection for critical infrastructure.
Physical Profile
The PDU31101 features a vertical form factor with dimensions of 65.50" height, 2.20" width, and 1.90" depth, designed for side-mounting in standard racks. Its 0U rack height means it installs without consuming vertical rack units, preserving space for other equipment. The all-metal black housing ensures durability and heat dissipation, while the 10-foot power cord provides reach to distant power sources. Weighing 13.20 lb, it is lightweight yet robust for secure mounting in dynamic environments.
- Width
- 2.20" (55.88 mm)
- Depth
- 1.90" (48.26 mm)
- Height
- 0U
- Weight
- 13.20 lb (5987.42 g)
- Length
- 10 ft (3.05 m)
What's in the Box
The package includes the PDU31101 unit and an adapter for immediate deployment.
Package contents include PDU31101 Adaptor, PDU31101. These included items support setup, installation, and immediate deployment without needing to source the core bundled accessories separately.
Highlights
- Monitored PDU with LCD display and LED status indicators
- Single phase 100-120V AC input, 20A capacity (derated to 16A)
- 24 locking NEMA 5-20R outlets for secure connections
- 0U vertical rackmount design saves rack space
- SNMP, HTTP, SSH, and CLI management protocols
- Overload protection and cord retention tray
- 10-foot power cord with NEMA L5-20P plug
- Metal construction, black finish, UL listed
- Operating temperature range 32°F to 140°F (0°C to 60°C)
- 3-year limited warranty
Specifications
| Specifications | |
|---|---|
| Manufacturer | CyberPower Systems, Inc |
| Manufacturer Part Number | PDU31101 |
| Brand Name | CyberPower |
| Product Series | Monitored PDU |
| Product Model | PDU31101 |
| Product Name | PDU31101 |
| Product Type | PDU |
| Technical Information | |
| PDU Type | Monitored |
| Phase | Single Phase |
| Plug/Connector Type | NEMA L5-20P |
| Receptacle Type | NEMA 5-20R |
| Receptacle Detail | 24 x NEMA 5-20R |
| Protection Type | Overload Protection |
| Locking Receptacles | Cord Retention Tray |
| Features | LCD Display,LED Status Indicator |
| Power Description | |
| Input Voltage | 120 V AC |
| Output Voltage | 100 V AC,120 V AC |
| Output Voltage Range | 100 V AC - 120 V AC |
| Input Current | 20 A |
| Input Frequency | 60 Hz |
| Management | |
| Management | Protocols: IPv4 TCP/IP UDP SNMPv1 HTTP NTP DNS Telnet DHCP SMTP FTP IPv6 SNMPv3 HTTPs SSH SSL TLS LDAP(S) RADIUS Syslog CLI Windows AD |
| Remote Outlet Switching | No |
| Interfaces/Ports | |
| Network (RJ-45) | Yes |
| Physical Characteristics | |
| Color Family | Black |
| Product Color | Black |
| Product Material | Metal |
| Mounting Orientation | Vertical |
| Mount Type | Rack-mountable,Wall-mountable |
| Form Factor | Rack |
| Rack Height | 0U |
| Cord Length | 10 ft (3.05 m) |
| Height | 65.50" (1663.70 mm) |
| Width | 2.20" (55.88 mm) |
| Depth | 1.90" (48.26 mm) |
| Weight (Approximate) | 13.20 lb (5987.42 g) |
| Environmental Conditions | |
| Minimum Operating Temperature | 32°F (0°C) |
| Maximum Operating Temperature | 140°F (60°C) |
| Minimum Storage Temperature | 5°F (-15°C) |
| Maximum Storage Temperature | 149°F (65°C) |
| Miscellaneous | |
| Package Contents | PDU31101 Adaptor |
| Country of Origin | China |
| TAA Compliant | No |
| Environmentally Friendly | Yes |
| Environmental Compliance | Restriction of Hazardous Substances (RoHS) |
| UL Listed | Yes |
| Warranty | |
| Limited Warranty | 3 Year |
User Manual
FAQ
What is the input voltage and current rating of the PDU31101?
The PDU31101 accepts a single-phase 120V AC input at 20A, with a derated continuous current of 16A. It provides an output voltage range of 100-120V AC, suitable for standard North American power infrastructure.
How many outlets does this PDU have and what type are they?
This PDU features 24 locking NEMA 5-20R receptacles. These outlets are designed to secure power cords in place, preventing accidental disconnections in rack or wall-mount installations.
Can the PDU31101 be mounted in a standard server rack?
Yes, the PDU31101 is designed for vertical mounting in standard 19" or 23" racks with a 0U height, meaning it does not consume any rack units. It also supports wall-mounting for flexible deployment in equipment rooms or network closets.
What management protocols are supported for monitoring?
The PDU supports a wide range of management protocols including SNMPv1/v3, HTTP/HTTPS, SSH, SSL/TLS, and CLI. This allows for integration into network management systems, automated notifications via email or SMS, and remote monitoring of power conditions.
Does this PDU include remote outlet switching capabilities?
No, the PDU31101 does not support remote outlet switching. It is a monitored PDU focused on providing real-time power data, overload protection, and alerting features rather than individual outlet control.
What is included in the warranty and compliance certifications?
The PDU31101 comes with a 3-year limited warranty from CyberPower. It is UL listed for safety, RoHS compliant for environmental standards, and constructed with metal housing for durability in commercial and data center environments.
What power capacity is listed for this UPS?
Power specifications help show where the unit fits best, including the type of load level, electrical environment, and backup role it is intended to support. These are usually the most decision-critical facts in a UPS or power-protection comparison.
How many outlets are available?
The product includes No, which helps buyers understand how many connected devices it can support in its intended deployment.