Sidebar Sidebar Sidebar
sale
Sold out

Shipping included*

Eaton T800R-02500 Power-Sure 800 Line Conditioner - 2. 50 kVA - 1. 75 kW - 120V AC - 4x NEMA 5-20R Outlets - Lightning & Surge Protection

SKU: T800R-02500
UPC: 743172022585
(No reviews) Write a Review
MSRP: $2,822.99
$2,822.99
$2,517.99
Save: $305.00 (10.80%)
Warranty Information: 2 Year
Condition: New
Width: 21.59 (cm)
Height: 44.45 (cm)
Depth: 32.39 (cm)

Ask for ETA! 🗨️

Logo cards
B2B Pricing

Business volume discounts

IT Experts

Technical guidance

IT Configuration

Preparation & staging

Canada Stock

QC · ON · AB · BC

Product Features

Description

Product Overview

The Eaton Power-Sure 800 Line Conditioner (model T800R-02500) delivers robust power conditioning for sensitive electronic equipment in commercial and industrial environments. This unit actively protects connected devices from a range of power quality issues, including lightning-induced surges, AC line surges, harmonic distortion, and AC noise interference. By stabilizing incoming power, it helps prevent data corruption, hardware damage, and unexpected downtime in critical systems.

Engineered for reliability, the conditioner provides a substantial 2.50 kVA (1.75 kW) load capacity, making it suitable for supporting multiple devices or high-draw equipment. Its design focuses on delivering clean, consistent 120V AC power through four dedicated NEMA 5-20R outlets, ensuring compatibility with standard North American office and server equipment. The heavy-duty construction and comprehensive protection suite position this unit as a foundational component for any power-sensitive installation.

Power
2.50 kW
Power Capacity
120 V AC
Power Capacity
Load Capacity (VA)2.50 kW
Load Capacity (Watt)1.75 kW
Input Voltage120 V AC
Protection & Connectivity
Protection TypeLightning, AC Surge, Harmonics, AC Noise
Plug/Connector TypeNEMA 5-30P
Receptacles Detail4 x NEMA 5-20R
Physical Profile
Height17.50" (444.50 mm)
Width8.50" (215.90 mm)
Depth12.75" (323.85 mm)

Technical Overview

This line conditioner employs advanced filtering and regulation technologies to mitigate specific power anomalies. It addresses lightning and AC surge events with high-energy absorption capabilities, safeguarding downstream electronics from transient voltage spikes. Simultaneously, its harmonic filtering reduces distortion caused by non-linear loads, while AC noise filtering eliminates high-frequency interference that can disrupt sensitive circuitry and data signals.

The power interface is built around a NEMA 5-30P input plug, designed for connection to a dedicated 30-amp circuit. Power distribution is handled through four NEMA 5-20R receptacles, each capable of delivering the conditioned 120V AC output. This configuration supports a mixed load environment typical of server racks, workstations, or medical equipment setups where stable power is non-negotiable.

This section brings together practical product details such as Protection Type, Plug/Connector Type, Receptacle Type, Load Capacity (VA), so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.

VA Rating2.50 kW
Watt Rating1.75 kW
Outlet Count4
120V AC InputNEMA 5-30P PlugHeavy-Duty Construction

Key Product Advantages

The Eaton Power-Sure 800 distinguishes itself through a multi-layered protection approach that goes beyond basic surge suppression. By conditioning the power line against four distinct threat vectors—lightning, AC surges, harmonics, and AC noise—it provides a more complete defense for equipment longevity and operational integrity. This proactive protection is critical for environments where power quality directly impacts productivity and equipment lifespan.

Comprehensive Threat Mitigation

Integrates protection against both high-energy transients (lightning/surge) and continuous power quality issues (harmonics/noise) in a single unit.

  • Absorbs damaging voltage spikes
  • Filters harmonic distortion from non-linear loads
  • Eliminates high-frequency line noise

Substantial Power Capacity

With a 2.50 kVA (1.75 kW) rating, this conditioner can support significant aggregated loads, making it suitable for protecting entire workstations or small server clusters.

  • Supports multiple high-draw devices
  • Prevents overload in mixed equipment environments
  • Maintains performance under full load

Deployment / Use Cases

This line conditioner is ideally deployed in locations where utility power is inconsistent or where connected equipment is particularly sensitive to power quality fluctuations. It serves as a critical infrastructure component in small to medium server rooms, protecting rack-mounted servers, network switches, and storage arrays from power-related failures and data errors. The unit's capacity and outlet configuration make it equally effective for securing medical diagnostic equipment, laboratory instruments, or audio/video production gear where clean power is essential for accurate operation.

In office environments, it can safeguard high-value workstations, design stations, or financial trading terminals from disruptive power events. The heavy-duty build and substantial weight indicate a design intended for permanent or semi-permanent installation, often within equipment racks or secured to floors in industrial settings. Its protection profile is particularly valuable in regions prone to electrical storms or in buildings with aging electrical infrastructure that introduces harmonics and noise.

Server & Network Infrastructure

Protects rack-mounted servers, switches, and NAS devices from data corruption and hardware damage caused by dirty power.

Sensitive Instrumentation

Ensures stable operation of medical, laboratory, or precision manufacturing equipment where power anomalies can skew readings or cause malfunctions.

Physical Profile

Constructed for durability, the conditioner measures 17.50" high, 8.50" wide, and 12.75" deep (444.5 x 215.9 x 323.85 mm), with an approximate weight of 68 lb (30.8 kg). These dimensions and the substantial weight suggest a robust, industrial-grade chassis designed to withstand continuous operation. The form factor is suitable for floor placement in equipment rooms or for integration into open-rack configurations using appropriate shelving. The heavy-gauge steel construction contributes to both physical protection and effective shielding against electromagnetic interference.

Dimensions
Width
8.50" (215.90 mm)
Depth
12.75" (323.85 mm)
Height
17.50" (444.50 mm)
Weight
68 lb (30844.28 g)
Rack-Compatible Dimensions
Industrial-Grade Chassis
68 lb Weight
[custom-highlights]

Highlights

  • 2.50 kVA / 1.75 kW load capacity for supporting multiple devices
  • Comprehensive protection against lightning, AC surge, harmonics, and AC noise
  • Four NEMA 5-20R outlets for connecting standard equipment
  • NEMA 5-30P input plug for 30-amp circuit connection
  • 120V AC input voltage for North American power systems
  • Heavy-duty construction with dimensions of 17.5"H x 8.5"W x 12.75"D
  • Approximate weight of 68 lb for stable, secure installation
  • 2-year limited warranty for added reliability assurance
[/custom-highlights][custom-specifications]

Specifications

Specifications
ManufacturerEaton Corporation
Manufacturer Part NumberT800R-02500
Brand NameEaton
Product LinePower-Sure
Product ModelT800R-02500
Product NamePower-Sure 800 Line Conditioner
Product TypeLine Conditioner
Technical Information
Protection TypeLightning,AC Surge,Harmonics,AC Noise
Plug/Connector TypeNEMA 5-30P
Receptacle TypeNEMA 5-20R
Receptacles Detail4 x NEMA 5-20R
Power Description
Load Capacity (VA)2.50 kW
Load Capacity (Watt)1.75 kW
Input Voltage120 V AC
Physical Characteristics
Height17.50" (444.50 mm)
Width8.50" (215.90 mm)
Depth12.75" (323.85 mm)
Weight (Approximate)68 lb (30844.28 g)
Warranty
Limited Warranty2 Year
[/custom-specifications][custom-user-manual]

User Manual

This section contains official documentation provided by the manufacturer, including product manuals, brochures, and supplementary materials.
[/custom-user-manual][custom-faq]

FAQ

What is the primary function of this Eaton line conditioner?

The Eaton Power-Sure 800 Line Conditioner actively cleans and stabilizes incoming AC power. It protects connected electronic equipment from four specific threats: lightning-induced voltage spikes, AC line surges, harmonic distortion created by non-linear loads, and high-frequency AC noise. This goes beyond simple surge protection by continuously conditioning the power to prevent data errors, hardware stress, and operational interruptions in sensitive devices.

What is the power capacity of the T800R-02500 model?

This model has a load capacity of 2.50 kilovolt-amperes (kVA), which equates to 1.75 kilowatts (kW) of real power. This capacity indicates the total amount of equipment it can support simultaneously. It is suitable for protecting a cluster of devices such as a server, network switch, and storage unit, or several high-performance workstations, ensuring they receive clean, regulated power without risk of overload.

How many devices can I connect to this unit?

The conditioner is equipped with four NEMA 5-20R receptacles. This allows you to connect up to four pieces of standard North American equipment that use a 5-20P plug. The total combined load of all connected devices must not exceed the unit's 2.50 kVA / 1.75 kW rating. This outlet configuration is typical for protecting a small server rack setup or a group of critical workstations.

What type of electrical circuit is required for installation?

The unit features a NEMA 5-30P plug, which is designed to connect to a dedicated 30-amp, 120-volt AC electrical circuit with a corresponding NEMA 5-30R receptacle. This circuit should be installed by a qualified electrician to ensure it meets local electrical codes and can safely deliver the required current. Do not use adapters to plug into a standard 15- or 20-amp outlet, as this could pose a fire hazard.

What are the physical dimensions and weight?

The conditioner measures 17.50 inches in height, 8.50 inches in width, and 12.75 inches in depth (444.5 mm H x 215.9 mm W x 323.85 mm D). It weighs approximately 68 pounds (30.8 kg). These dimensions are compatible with many 19-inch equipment racks when used with a suitable shelf, and the substantial weight contributes to stability. Ensure your installation location—whether a rack shelf or floor—can support this weight.

What warranty coverage does Eaton provide for this product?

Eaton backs the Power-Sure 800 Line Conditioner with a 2-year limited warranty. This warranty covers defects in materials and workmanship under normal use and service. For specific terms, conditions, and the process for making a warranty claim, refer to the official Eaton warranty documentation included with the product or available from Eaton's support resources.

What power capacity is listed for this UPS?

The listed power specification is 2.50 kW, which helps position the unit for the right load level and installation role.

What voltage details are listed?

The listed power specification is 120 V AC, which helps position the unit for the right load level and installation role.

[/custom-faq]
Volume Discounts
Qty Price Available
Match Price Request

Found a lower price? Send us the link and we will do our best to match or beat it.

Request received. We will reply within 24 hours.
Fleet Network
Wholesale & B2B
Partner with Us

Looking to buy in bulk? We offer competitive pricing, dedicated support, and custom solutions for businesses of all sizes.

Volume Discounts

Tiered pricing structure designed to maximize your margins as you grow.

Dedicated Account Manager

Direct access to a specialist who understands your business needs.

Fast & Reliable Shipping

Priority processing and discounted shipping rates for bulk orders.

Request a Quote
Thank you!
Your request has been sent successfully.
Eaton T800R-02500 Power-Sure 800 Line Conditioner - 2. 50 kVA - 1. 75 kW - 120V AC - 4x NEMA 5-20R Outlets - Lightning & Surge Protection
MSRP: $2,822.99
$2,822.99
$2,517.99
Save: $305.00 (10.80%)
Out of stock