Technical Overview
Engineered for high-density power distribution, the RPM3016I2LCD-HW features a hardwired connection supporting 30A input current, ensuring stable power delivery to connected equipment. The outlet configuration includes 14 IEC C13 receptacles and 2 IEC C19 receptacles, accommodating a mix of standard and high-power devices such as servers, switches, and storage arrays.
Network management is comprehensive, with support for IPv6, SNMPv3, TLS/SSL, and legacy SNMP versions, allowing integration into diverse IT environments. The built-in circuit protection safeguards against electrical faults, while the RJ-45 network port enables seamless connectivity to existing network infrastructure for remote access and control.
This section brings together practical product details such as PDU Type, Plug/Connector Type, Receptacle Type, Input Current, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
A strong technical summary explains how the product's interfaces, hardware profile, and operating characteristics work together in real deployment. Buyers often need this context to confirm compatibility with existing devices, expected performance in daily use, and whether installation will be straightforward for IT staff or end users.
Key Product Advantages
This PDU stands out by combining remote power control with a compact, space-saving design, offering IT administrators unparalleled flexibility and reliability in power management.
Remote Power Management
Control individual outlets remotely via web browser or SNMP, allowing for scheduled reboots, power sequencing, and emergency shutdowns without physical access to the rack.
- Outlet-level switching
- Web and SNMP control
- Power sequencing
Proactive Monitoring and Alerts
Monitor power status, set thresholds, and receive email notifications for overloads or faults, enabling proactive maintenance and reducing downtime risks.
- Threshold sensing
- Overload alerts
- Mail notification
Centralized Management Software
Leverage free centralized monitoring software to manage multiple PDUs from a single interface, streamlining operations in large-scale deployments.
Deployment / Use Cases
The Minuteman RPM3016I2LCD-HW is tailored for environments where remote power management and rack space efficiency are critical. Its switched capabilities and compact form factor make it suitable for a range of professional IT settings.
In data centers, this PDU enables administrators to reboot unresponsive servers or network gear remotely, reducing the need for on-site visits and minimizing service interruptions. For server rooms or network closets in branch offices, the 0U vertical mounting conserves valuable rack space while providing enterprise-grade power control. IT labs and development environments benefit from the ability to power cycle equipment on a schedule, supporting automated testing and energy-saving initiatives.
Data Center Power Control
Manage high-density server racks with individual outlet control, ensuring uptime and simplifying maintenance in critical infrastructure.
Remote Office IT Management
Deploy in distributed locations to remotely troubleshoot and reboot equipment, reducing travel costs and improving response times for IT support.
Highlights
- Switched PDU with remote outlet control via network
- Hardwired 30A input for reliable high-current power distribution
- 16 total outlets: 14 IEC C13 and 2 IEC C19 receptacles
- 0U vertical rack-mount design saves valuable rack space
- Network management with IPv6, SNMPv3, TLS/SSL, and web interface
- Includes free centralized monitoring software for multi-PDU management
- Features mail notification, threshold sensing, and overload alerts
- Circuit protection safeguards connected equipment
Specifications
| Specifications | |
|---|---|
| Manufacturer | Para Systems, Inc |
| Manufacturer Part Number | RPM3016I2LCD-HW |
| Brand Name | Minuteman |
| Product Series | RPM |
| Product Model | RPM3016I2LCD-HW |
| Product Name | RPM3016I2LCD-HW 16-Outlets PDU |
| Product Type | PDU |
| Technical Information | |
| PDU Type | Switched |
| Plug/Connector Type | Hardwired |
| Receptacle Type | IEC 60320 C13,IEC 60320 C19 |
| Receptacle Detail | 14 x IEC 60320 C13,2 x IEC 60320 C19 |
| Protection Type | Circuit Protection |
| Power Description | |
| Input Current | 30 A |
| Management | |
| Management | IPv6 SNMPv3 TLS/SSL SNMP (v1,v2c,v3) |
| Remote Outlet Switching | Yes |
| Interfaces/Ports | |
| Network (RJ-45) | Yes |
| Physical Characteristics | |
| Mounting Orientation | Vertical |
| Mount Type | Rack-mountable |
| Rack Height | 0U |
FAQ
What is the input current rating of this PDU?
The Minuteman RPM3016I2LCD-HW has a hardwired input current rating of 30 amps, providing robust power capacity for distributing electricity to multiple connected devices in a rack environment.
How many outlets does this PDU have and what types are they?
This PDU features 16 total outlets, consisting of 14 IEC 60320 C13 receptacles and 2 IEC 60320 C19 receptacles. The C13 outlets are standard for most IT equipment, while the C19 outlets support higher-power devices like servers or UPS units.
Can I control individual outlets remotely with this PDU?
Yes, this is a switched PDU that supports remote outlet switching. You can control each outlet individually over the network using a web browser or SNMP protocols, allowing for remote reboots, power sequencing, and scheduled on/off cycles.
What management protocols are supported for network access?
The PDU supports IPv6, SNMPv3, TLS/SSL, and legacy SNMP versions (v1, v2c, v3). This comprehensive protocol support ensures compatibility with various network management systems and enhances security through encrypted communications.
How is this PDU mounted in a rack?
This PDU is designed for vertical mounting in standard 19-inch racks and occupies 0U of rack height. The vertical orientation allows installation along the side of the rack, saving space and facilitating cable management without consuming rack units.
Does this PDU include monitoring and alerting features?
Yes, it includes features such as threshold sensing, overload alerts, and mail notification. These capabilities enable proactive monitoring of power status, allowing administrators to receive alerts and take action before issues escalate, supported by free centralized management software.
What power capacity is listed for this UPS?
Power specifications help show where the unit fits best, including the type of load level, electrical environment, and backup role it is intended to support. These are usually the most decision-critical facts in a UPS or power-protection comparison.
How many outlets are available?
The product includes Yes, which helps buyers understand how many connected devices it can support in its intended deployment.