Shipping included*
Exclusions
Additional shipping fees may apply in rare circumstances for deliveries outside standard service areas. In most cases, this only potentially affects shipments to the Northwest Territories and Yukon, as well as certain heavy or oversized items.
Liebert MP2-130HW MicroPOD 24A Maintenance Bypass Switch - 110V AC Input - 120V AC Output - 2U Rack-Mountable
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
The MP2-130HW maintenance bypass switch operates with a 110V AC input voltage and provides a 120V AC output at 24A current capacity. This electrical configuration allows for seamless integration into typical single-phase power infrastructures, supporting equipment that requires stable 120V AC power.
The switch incorporates both surge protection and over-current protection mechanisms to prevent damage from voltage spikes and excessive current draw. These built-in safeguards help maintain uptime and protect sensitive electronics connected to the bypass circuit.
This section brings together practical product details such as Plug/Connector Type, Receptacles, Protection Type, Input Voltage, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
A strong technical summary explains how the product's interfaces, hardware profile, and operating characteristics work together in real deployment. Buyers often need this context to confirm compatibility with existing devices, expected performance in daily use, and whether installation will be straightforward for IT staff or end users.
Key Product Advantages
The Liebert MicroPOD MP2-130HW maintenance bypass switch offers several advantages for power management in rack environments. Its compact 2U form factor maximizes rack space efficiency while providing essential bypass functionality for maintenance operations.
These strengths make the product easier to deploy and manage in real environments, especially where reliability, usability, and day-to-day operational continuity matter. Notable benefits include Maintenance Safety, Rack Integration.
Maintenance Safety
Enables safe equipment maintenance by providing a bypass path that keeps downstream devices powered while isolating the equipment being serviced.
- Prevents service interruptions
- Maintains power to connected devices
- Reduces downtime during maintenance
Rack Integration
Designed specifically for rack mounting with standard 2U height and 17-inch width that fits standard 19-inch rack enclosures.
- Space-efficient 2U design
- Standard rack compatibility
- Professional installation ready
Deployment / Use Cases
The MP2-130HW maintenance bypass switch is ideal for environments where continuous power availability is critical during equipment maintenance. Data centers can deploy this switch to maintain power to servers and networking equipment while performing maintenance on upstream power distribution units or UPS systems.
Network operations centers benefit from the ability to service power equipment without disrupting connected switches, routers, and security appliances. The hardwired connection option provides flexibility for permanent installations where plug-and-play receptacles may not be suitable.
This section brings together practical product details such as Plug/Connector Type, Receptacles, Protection Type, Input Voltage, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
Data Center Maintenance
Facilitates safe maintenance of power distribution equipment while keeping server racks operational during service procedures.
Network Infrastructure
Enables maintenance of power sources without interrupting connectivity to critical networking equipment in server rooms and telecom closets.
Physical Profile
The MP2-130HW features a compact 2U rack-mountable design with dimensions of 3.50 inches in height, 17 inches in width, and 3.50 inches in depth (88.90 mm x 431.80 mm x 88.90 mm). This form factor optimizes rack space utilization while providing full bypass functionality. The unit's standard width ensures compatibility with 19-inch rack enclosures commonly used in data centers and equipment rooms.
- Width
- 17" (431.80 mm)
- Depth
- 3.50" (88.90 mm)
- Height
- 2U
What's in the Box
The package includes the complete maintenance bypass switch unit along with documentation for proper installation and operation.
Highlights
- 24A maintenance bypass switch for critical power applications
- 110V AC input with 120V AC output at 24A capacity
- 2U rack-mountable form factor for space-efficient installation
- Surge and over-current protection for connected equipment
- Hardwired connection with NEMA 5-30R receptacle
- Compact dimensions: 3.50" H x 17" W x 3.50" D
- Enables safe equipment maintenance without power interruption
- Includes user manual for proper installation guidance
Specifications
| Specifications | |
|---|---|
| Manufacturer | Vertiv |
| Manufacturer Part Number | MP2-130HW |
| Brand Name | Vertiv Liebert |
| Product Line | MicroPOD |
| Product Model | MP2-130HW |
| Product Name | MicroPOD MP2-130HW 24A Maintenance Bypass Switch |
| Product Type | Bypass Switch |
| Technical Information | |
| Plug/Connector Type | Hardwired |
| Receptacles | 1 x NEMA 5-30R,1 x Hardwired |
| Protection Type | Surge,Over Current |
| Power Description | |
| Input Voltage | 110 V AC |
| Output Voltage | 120 V AC |
| Current | 24 A |
| Physical Characteristics | |
| Form Factor | Rack-mountable |
| Rack Height | 2U |
| Height | 3.50" (88.90 mm) |
| Width | 17" (431.80 mm) |
| Depth | 3.50" (88.90 mm) |
| Miscellaneous | |
| Package Contents | MicroPOD MP2-130HW 24A Maintenance Bypass Switch User manual |
| Warranty | |
| Limited Warranty | 2 Year |
FAQ
What is the purpose of a maintenance bypass switch?
A maintenance bypass switch allows you to safely bypass connected equipment during maintenance or service procedures while keeping power flowing to downstream devices. This prevents service interruptions and enables maintenance personnel to work on power distribution equipment without disrupting connected servers, networking gear, or other critical infrastructure.
What input voltage does the MP2-130HW support?
The Liebert MicroPOD MP2-130HW maintenance bypass switch accepts 110V AC input voltage. This standard North American voltage allows the switch to integrate seamlessly with typical single-phase power infrastructures found in data centers, server rooms, and commercial facilities across the United States and Canada.
What output does this bypass switch provide?
The MP2-130HW delivers 120V AC output at 24A current capacity. This output configuration matches standard North American power requirements for most rack-mounted equipment, including servers, network switches, storage arrays, and other data center infrastructure that operates on 120V AC power.
How is this switch mounted in a rack?
The MP2-130HW features a 2U rack-mountable form factor with standard dimensions that fit 19-inch rack enclosures. The unit measures 3.50 inches in height (2U), 17 inches in width, and 3.50 inches in depth, making it compatible with standard data center racks and server cabinets for professional installation.
What types of electrical protection does this switch include?
The MP2-130HW maintenance bypass switch incorporates both surge protection and over-current protection. The surge protection safeguards connected equipment against voltage spikes and transient electrical events, while the over-current protection prevents damage from excessive current draw, ensuring reliable operation of downstream devices.
What connections are available on this bypass switch?
The MP2-130HW provides two connection options: one NEMA 5-30R receptacle and one hardwired connection point. The NEMA 5-30R receptacle accepts standard 30A plugs, while the hardwired option allows for permanent electrical connections, providing flexibility for different installation requirements in data centers and equipment rooms.
What power capacity is listed for this UPS?
Power specifications help show where the unit fits best, including the type of load level, electrical environment, and backup role it is intended to support. These are usually the most decision-critical facts in a UPS or power-protection comparison.
What voltage details are listed?
The listed power specification is 110 V AC, which helps position the unit for the right load level and installation role.