Shipping included*
Exclusions
Additional shipping fees may apply in rare circumstances for deliveries outside standard service areas. In most cases, this only potentially affects shipments to the Northwest Territories and Yukon, as well as certain heavy or oversized items.
Liebert MP2-220L MicroPOD External Maintenance Bypass Switch - 3 kW - 230 V AC - 10 A/16 A - Rack-mountable 2U
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This external maintenance bypass switch operates with a 230 V AC input voltage and supports loads up to 3 kW, making it suitable for small to medium business server rooms, network closets, and edge computing environments. The dual current rating of 10 A and 16 A accommodates varying power demands while maintaining safe operational parameters during maintenance bypass procedures.
The IEC 60320 C20 connector ensures reliable power interface compatibility, while the rack-mountable 2U design provides standardized installation within 19-inch server racks. Physical dimensions of 3.46 inches in height, 15.51 inches in width, and 3.03 inches in depth create a compact footprint that maximizes rack space utilization without compromising functionality.
This section brings together practical product details such as Plug/Connector Type, Load Capacity (VA), Input Voltage, Current, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
Key Product Advantages
The Liebert MP2-220L enhances UPS system maintainability by providing a dedicated external bypass path that eliminates the need to power down protected equipment during service intervals. This capability minimizes operational downtime and maintains business continuity while allowing technicians to safely perform maintenance, testing, or replacement procedures on connected UPS units.
Safe Maintenance Operations
Enables isolation of UPS systems from critical loads without interrupting power to connected equipment, reducing risk during service procedures.
- Maintains continuous power flow
- Isolates UPS for safe servicing
- Reduces operational downtime
Rack-Optimized Design
2U rack-mountable form factor integrates efficiently into standard server cabinets, supporting organized infrastructure management.
- Standard 19-inch rack compatibility
- Compact 2U height
- Black finish for professional appearance
Liebert System Integration
Specifically designed for compatibility with Liebert GXT5, GXT RT+, and Edge UPS systems, ensuring reliable performance within the Vertiv ecosystem.
- Verified compatibility
- Ecosystem integration
- Reliable performance
Deployment / Use Cases
The MP2-220L External Maintenance Bypass Switch is deployed in environments where maintaining continuous power availability during UPS maintenance is critical. Server rooms supporting business applications, network operations centers, healthcare IT infrastructure, and financial services data environments benefit from the ability to service power protection systems without disrupting connected equipment.
Edge computing locations with limited technical staffing can utilize this bypass switch to simplify maintenance procedures, while managed service providers appreciate the standardized rack-mountable design for consistent deployment across multiple client sites. The 3 kW capacity makes it suitable for protecting single servers, network switches, storage arrays, or small server clusters where scheduled maintenance must occur without business interruption.
Server Room Maintenance
Facilitates scheduled UPS maintenance in business server environments without requiring equipment shutdowns that disrupt operations.
Edge Infrastructure Support
Provides maintenance capability for distributed IT locations where technical resources may be limited but uptime requirements remain high.
Physical Profile
The black-finished bypass switch features a compact 2U rack-mountable design with dimensions of 3.46 inches in height, 15.51 inches in width, and 3.03 inches in depth. Weighing approximately 4.41 pounds, the unit installs easily into standard 19-inch server racks using appropriate mounting hardware. The professional black finish matches typical data center and server room aesthetics while the standardized form factor ensures compatibility with common rack configurations and cable management systems.
- Width
- 15.51" (394 mm)
- Depth
- 3.03" (77 mm)
- Height
- 2U
- Weight
- 4.41 lb (2000 g)
Highlights
- 3 kW load capacity for small to medium power protection needs
- 230 V AC input voltage suitable for standard commercial power
- Dual current rating of 10 A and 16 A for configuration flexibility
- Rack-mountable 2U form factor for organized infrastructure deployment
- Compatible with Liebert GXT5, GXT RT+, and Edge UPS systems
- IEC 60320 C20 connector for reliable power interface
- Black finish matches professional server room aesthetics
- 2-year limited warranty for product assurance
Specifications
| Specifications | |
|---|---|
| Manufacturer | Vertiv |
| Manufacturer Part Number | MP2-220L |
| Brand Name | Vertiv Liebert |
| Product Line | MicroPOD |
| Product Name | MicroPOD External Maintenance Bypass Switch |
| Product Type | Bypass Switch |
| Technical Information | |
| Plug/Connector Type | IEC 60320 C20 |
| Power Description | |
| Load Capacity (VA) | 3 kW |
| Input Voltage | 230 V AC |
| Current | 10 A,16 A |
| Physical Characteristics | |
| Color Family | Black |
| Product Color | Black |
| Form Factor | Rack-mountable |
| Rack Height | 2U |
| Height | 3.46" (88 mm) |
| Width | 15.51" (394 mm) |
| Depth | 3.03" (77 mm) |
| Weight (Approximate) | 4.41 lb (2000 g) |
| Miscellaneous | |
| Compatibility | Liebert GXT5, GXT RT+, Edge UPS |
| Warranty | |
| Limited Warranty | 2 Year |
FAQ
What is the primary function of this Liebert bypass switch?
The Liebert MP2-220L External Maintenance Bypass Switch provides a dedicated path to bypass connected UPS systems during maintenance procedures. This allows technicians to safely service, test, or replace UPS units while maintaining continuous power flow to the critical load, eliminating the need to power down protected equipment during service intervals.
What power capacity does this bypass switch support?
This bypass switch supports loads up to 3 kW at 230 V AC input voltage. The dual current rating of 10 A and 16 A provides flexibility for different power configurations, making it suitable for protecting single servers, network equipment, or small server clusters in business environments.
Which Liebert UPS systems are compatible with this bypass switch?
The MP2-220L is specifically designed for compatibility with Liebert GXT5, GXT RT+, and Edge UPS systems. This verified compatibility ensures reliable performance within the Vertiv power protection ecosystem, providing a maintenance solution tailored to these UPS models.
How is this bypass switch installed in a server rack?
The switch features a 2U rack-mountable form factor designed for installation in standard 19-inch server racks. With dimensions of 3.46 inches in height, 15.51 inches in width, and 3.03 inches in depth, it integrates efficiently using appropriate rack mounting hardware. The compact design maximizes rack space utilization while maintaining accessibility for maintenance operations.
What type of power connector does this bypass switch use?
This bypass switch utilizes an IEC 60320 C20 connector for power interface. This standardized connector type ensures reliable connections and compatibility with appropriate power cables, supporting the 230 V AC input voltage and dual current ratings of 10 A and 16 A.
What warranty coverage is provided with this product?
The Liebert MP2-220L External Maintenance Bypass Switch comes with a 2-year limited warranty. This warranty provides assurance against manufacturing defects and supports reliable operation within the specified technical parameters when used with compatible Liebert UPS systems.
What power capacity is listed for this UPS?
The listed power specification is 3 kW, which helps position the unit for the right load level and installation role.
What voltage details are listed?
The listed power specification is 230 V AC, which helps position the unit for the right load level and installation role.