Shipping included*
Exclusions
Additional shipping fees may apply in rare circumstances for deliveries outside standard service areas. In most cases, this only potentially affects shipments to the Northwest Territories and Yukon, as well as certain heavy or oversized items.
Panduit P36G22M-BL1A SmartZone G5 Intelligent Monitored PDU - 36 Outlets - 30x C13 - 6x C19 - 208V AC - 8. 60 kW - 0U Rack-Mountable
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This monitored PDU features a robust electrical design with an 8.60 kW (8.60 VA) power rating and 30A input current, suitable for powering high-density server racks, networking gear, and storage arrays. The input and output voltage is 208V AC, maintaining consistent power delivery without conversion losses. The three-phase power configuration enhances load balancing and reduces the risk of single-phase overloads in demanding environments.
Network connectivity via RJ-45 enables remote monitoring and management through standard IP networks, allowing integration with existing data center infrastructure management (DCIM) tools. The PDU's active metering capabilities provide per-outlet or aggregate power data, including voltage, current, power factor, and energy consumption metrics. This technical foundation supports proactive maintenance and capacity planning.
This section brings together practical product details such as PDU Type, Phase, Plug/Connector Type, Input Voltage, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
Key Product Advantages
The SmartZone G5 PDU offers several advantages for power management in critical IT environments. Its intelligent monitoring system provides early warnings before input sources become overloaded, helping prevent downtime and equipment damage. The active metering functionality enables detailed energy optimization and circuit protection, allowing administrators to identify underutilized or inefficient devices.
Energy Optimization
Real-time power data helps reduce energy waste and supports sustainability initiatives by identifying high-consumption devices.
- Active metering per outlet
- Historical consumption tracking
- Power factor monitoring
Overload Protection
Proactive alerts notify administrators of approaching capacity limits, enabling load redistribution before critical thresholds are reached.
- Configurable alarm thresholds
- Visual and remote notifications
- Circuit breaker coordination
Deployment / Use Cases
This PDU is ideal for deployment in data centers, server rooms, network closets, and colocation facilities where reliable power distribution and monitoring are essential. Its 36-outlet configuration supports high-density server racks, blade chassis, networking switches, and storage systems, reducing the need for multiple power strips and simplifying cable management.
The vertical 0U mounting design makes it particularly suitable for racks with limited horizontal space, as it installs along the side or rear of the enclosure without consuming rack units. The combination of C13 and C19 outlets accommodates both standard server power cords and higher-current equipment, providing flexibility for mixed IT environments. The three-phase 208V AC power is commonly used in North American data centers, ensuring compatibility with existing power infrastructure.
Data Center Racks
Power high-density server deployments with precise monitoring for capacity planning and energy billing.
Network Equipment Closets
Distribute power to switches, routers, and security appliances while monitoring total load.
Physical Profile
The PDU features a compact vertical design with dimensions of 2.05" (51.99 mm) width, 2.10" (53.34 mm) depth, and 68.90" (1750.01 mm) length, optimized for installation in standard 19-inch rack enclosures. The 0U rack height means it mounts vertically without consuming rack units, preserving space for active equipment. The vertical mounting orientation and rack-mountable construction ensure secure installation in both front and rear rack positions.
- Width
- 2.05" (51.99 mm)
- Depth
- 2.10" (53.34 mm)
- Height
- 0U
- Length
- 68.90" (1750.01 mm)
Highlights
- Intelligent monitored PDU with active metering for energy optimization
- 36 total outlets: 30 x IEC C13 and 6 x IEC C19 receptacles
- 8.60 kW (8.60 VA) power rating with 30A input current
- Three-phase 208V AC input and output voltage
- 0U vertical rack-mountable design for space efficiency
- Network connectivity via RJ-45 for remote management
- NEMA L15-30P plug connector for three-phase power sources
- RoHS compliant and environmentally friendly construction
- 3-year limited warranty for long-term reliability
Specifications
| Specifications | |
|---|---|
| Manufacturer | PANDUIT CORP |
| Manufacturer Part Number | P36G22M-BL1A |
| Brand Name | Panduit |
| Product Line | SmartZone |
| Product Series | MSPO |
| Product Name | SmartZone G5 Intelligent 36-Outlets PDU |
| Packaged Quantity | 1 |
| Product Type | PDU |
| Technical Information | |
| PDU Type | Monitored |
| Phase | Three Phase |
| Plug/Connector Type | NEMA L15-30P |
| Receptacle Type | IEC 60320 C13,IEC 60320 C19 |
| Receptacle Detail | 30 x IEC 60320 C13,6 x IEC 60320 C19 |
| Power Description | |
| Input Voltage | 208 V AC |
| Output Voltage | 208 V AC |
| Power Rating (VA) | 8.60 VA |
| Power Rating (Watt) | 8.60 kW |
| Input Current | 30 A |
| Interfaces/Ports | |
| Network (RJ-45) | Yes |
| Physical Characteristics | |
| Mounting Orientation | Vertical |
| Mount Type | Rack-mountable |
| Rack Height | 0U |
| Width | 2.05" (51.99 mm) |
| Depth | 2.10" (53.34 mm) |
| Length | 68.90" (1750.01 mm) |
| Miscellaneous | |
| Environmentally Friendly | Yes |
| Environmental Compliance | Restriction of Hazardous Substances (RoHS) |
| Warranty | |
| Limited Warranty | 3 Year |
User Manual
FAQ
What is the power capacity of this Panduit PDU?
This SmartZone G5 PDU has a power rating of 8.60 kW (8.60 VA) with a 30A input current. It supports three-phase 208V AC power, making it suitable for high-density server racks and networking equipment that require substantial power distribution.
How many outlets does this PDU have and what types are they?
The PDU features 36 total outlets: 30 IEC 60320 C13 receptacles and 6 IEC 60320 C19 receptacles. This combination accommodates standard server power cords (C13) and higher-current equipment requiring C19 connectors, providing flexibility for mixed IT environments.
What does 'monitored' mean for this PDU?
Monitored indicates the PDU provides active metering capabilities, enabling real-time monitoring of power consumption, voltage, current, and other electrical parameters. This allows for energy optimization, circuit protection, and early warnings before input sources become overloaded, helping prevent downtime.
How is this PDU mounted in a rack?
This PDU uses a 0U vertical rack-mountable design, meaning it installs along the side or rear of a standard 19-inch rack without consuming rack units. It has a vertical mounting orientation with dimensions of 2.05" width, 2.10" depth, and 68.90" length, optimized for space-efficient installation.
What type of power input does this PDU require?
The PDU requires a three-phase 208V AC power source with a NEMA L15-30P plug connector. The output voltage is also 208V AC, maintaining consistent power delivery without conversion losses, which is common in North American data center environments.
Does this PDU support remote management?
Yes, the PDU includes network connectivity via an RJ-45 port, enabling remote monitoring and management over IP networks. This allows integration with data center infrastructure management (DCIM) tools for centralized control, alerting, and reporting of power metrics.
What power capacity is listed for this UPS?
The listed power specification is 8.60 VA, which helps position the unit for the right load level and installation role.
What voltage details are listed?
The listed power specification is 208 V AC, which helps position the unit for the right load level and installation role.