Panduit P42D07G G6 Monitored PDU - 42 Outlets - 36x C13 - 6x C19 - 17. 3 kW - 415V AC - NEMA L22-30P - SNMP - Rack-Mountable 43U
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This monitored PDU operates on a three-phase electrical system with a 415 V AC input voltage and delivers 240 V AC output. It supports a maximum input current of 30 A at 60 Hz, providing stable power for high-density server deployments. The unit includes both IEC C13 and C19 receptacles to accommodate a variety of power cords for servers, switches, and storage devices.
Network connectivity is provided via an RJ-45 port, enabling integration into existing management systems. The onboard display offers local visibility into power metrics, while SNMP support allows for remote monitoring and alerting. This technical configuration is designed for environments where power visibility and control are essential for uptime and efficiency.
This section brings together practical product details such as PDU Type, Phase, Plug/Connector Type, Input Voltage, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
Key Product Advantages
The Panduit G6 PDU combines high outlet density with advanced monitoring capabilities, making it a strategic choice for modern data centers. Its 42-outlet configuration maximizes power distribution within a single rack unit, reducing clutter and simplifying cable management.
High-Density Power Distribution
With 36 C13 and 6 C19 outlets, this PDU supports a mix of equipment, from 1U servers to larger devices requiring higher-current connections, all within a compact footprint.
- 42 total outlets
- Mix of C13 and C19
- 17.3 kW capacity
Remote Monitoring & Management
SNMP compatibility allows integration with network management systems for real-time power monitoring, historical trending, and proactive alerting on power anomalies.
- SNMP protocol
- Onboard display
- RJ-45 network port
Rack-Optimized Design
The vertical 43U mounting orientation and 2-inch width are engineered for standard server racks, ensuring efficient use of space and easy installation alongside other equipment.
- 43U rack height
- Vertical mount
- Black finish
Deployment / Use Cases
This PDU is ideal for data centers, server rooms, and network closets where reliable, monitored power distribution is required for high-density IT equipment. Its three-phase power and high outlet count make it suitable for environments with multiple servers, storage arrays, and networking gear.
Common deployment scenarios include enterprise server racks, colocation facilities, and cloud infrastructure deployments. The unit's monitoring capabilities support IT teams in managing power capacity, planning for expansion, and maintaining uptime through proactive power management.
Data Center Server Racks
Deploy in standard 19-inch server racks to power multiple servers, switches, and storage devices, with remote monitoring for capacity planning and fault detection.
High-Density IT Environments
Use in environments where equipment density is high, such as virtualization clusters or high-performance computing setups, to distribute power efficiently and monitor load conditions.
Physical Profile
The PDU features a slim 2-inch width and 2.10-inch depth, designed for vertical mounting in standard server racks. Its 74.60-inch height corresponds to 43U of rack space, making it compatible with full-height server cabinets. The black finish provides a professional appearance that blends with typical rack equipment.
- Width
- 2" (50.80 mm)
- Depth
- 2.10" (53.34 mm)
- Height
- 43U
- Length
- 10 ft (3.05 m)
What's in the Box
The package includes the G6 42-Outlets PDU and all necessary mounting hardware for installation in a standard server rack.
Package contents include G6 42-Outlets PDU Mounting Hardware, G6 42-Outlets PDU. These included items support setup, installation, and immediate deployment without needing to source the core bundled accessories separately.
Highlights
- 42 total outlets: 36 IEC C13 and 6 IEC C19 receptacles
- 17.3 kW power capacity for high-density equipment
- Three-phase power with 415 V AC input and 240 V AC output
- Monitored PDU with SNMP management and onboard display
- NEMA L22-30P plug and 10-foot power cord
- Vertical rack-mount design for 43U server cabinets
- Network connectivity via RJ-45 port for remote monitoring
- Operating temperature range of 50°F to 140°F (10°C to 60°C)
- 3-year limited warranty from Panduit
- Black finish for professional rack integration
Specifications
| Specifications | |
|---|---|
| Manufacturer | PANDUIT CORP |
| Manufacturer Part Number | P42D07G |
| Brand Name | Panduit |
| Product Series | G6 |
| Product Name | G6 42-Outlets PDU |
| Packaged Quantity | 1 |
| Product Type | PDU |
| Technical Information | |
| PDU Type | Monitored |
| Phase | Three Phase |
| Plug/Connector Type | NEMA L22-30P |
| Receptacle Type | IEC 60320 C13,IEC 60320 C19 |
| Receptacle Detail | 36 x IEC 60320 C13,6 x IEC 60320 C19 |
| Features | Onboard Display |
| Load Capacity (Watt) | 17.30 kW |
| Power Description | |
| Input Voltage | 415 V AC |
| Output Voltage | 240 V AC |
| Power Rating (Watt) | 17.30 kW |
| Input Current | 30 A |
| Input Frequency | 60 Hz |
| Management | |
| Management | SNMP |
| Interfaces/Ports | |
| Network (RJ-45) | Yes |
| Physical Characteristics | |
| Product Color | Black |
| Mounting Orientation | Vertical |
| Mount Type | Rack-mountable |
| Rack Height | 43U |
| Cord Length | 10 ft (3.05 m) |
| Height | 74.60" (1894.84 mm) |
| Width | 2" (50.80 mm) |
| Depth | 2.10" (53.34 mm) |
| Environmental Conditions | |
| Minimum Operating Temperature | 50°F (10°C) |
| Maximum Operating Temperature | 140°F (60°C) |
| Minimum Storage Temperature | 24.8°F (-4°C) |
| Maximum Storage Temperature | 284°F (140°C) |
| Miscellaneous | |
| Package Contents | G6 42-Outlets PDU Mounting Hardware |
| Warranty | |
| Limited Warranty | 3 Year |
User Manual
FAQ
What is the total power capacity of this PDU?
The Panduit G6 PDU has a load capacity of 17.30 kW (17,300 watts). This capacity supports high-density server and networking equipment deployments in data center environments, providing sufficient power for multiple devices simultaneously.
How many outlets does this PDU have and what types are they?
This PDU features 42 outlets total: 36 IEC 60320 C13 receptacles and 6 IEC 60320 C19 receptacles. The C13 outlets are common for servers and networking gear, while the C19 outlets support higher-current devices like larger servers or storage arrays.
What input voltage and plug type does this PDU use?
The PDU requires a 415 V AC three-phase input and uses a NEMA L22-30P plug. This configuration is typical for commercial and data center power systems, providing efficient power distribution for high-load equipment.
How is this PDU monitored and managed?
This is a monitored PDU with SNMP (Simple Network Management Protocol) support and an onboard display. The RJ-45 network port allows integration into network management systems for remote monitoring of voltage, current, and load conditions, enabling proactive power management.
What are the rack mounting specifications?
The PDU is designed for vertical rack mounting and occupies 43U of rack space. Its dimensions are 74.60 inches in height, 2 inches in width, and 2.10 inches in depth, making it compatible with standard 19-inch server racks commonly used in data centers.
What is included in the warranty for this PDU?
Panduit provides a 3-year limited warranty for this G6 PDU. This warranty covers defects in materials and workmanship under normal use, offering protection for your power distribution investment in critical IT environments.
What power capacity is listed for this UPS?
The listed power specification is 17.30 kW, which helps position the unit for the right load level and installation role.
What voltage details are listed?
The listed power specification is 415 V AC, which helps position the unit for the right load level and installation role.