Liebert PD2-103 8-Outlet PDU for GXT 8/10kVA POD - Hardwire Terminal Block Input - 4x NEMA 5-20R & 4x L6-30R Outlets
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
The PD2-103 employs a hardwire terminal block connection with 3-wire plus ground configuration for secure input power delivery. This connection method ensures stable power transmission to connected equipment while maintaining electrical safety standards.
Output distribution is handled through eight dedicated receptacles: four NEMA 5-15R/20R outlets suitable for standard IT equipment, and four NEMA L6-30R outlets designed for higher-power devices. The unit supports input voltages of both 120V and 230V AC, providing flexibility for different electrical environments.
This section brings together practical product details such as Plug/Connector Type, Plug/Connector Detail, Receptacle Type, Input Voltage, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
A strong technical summary explains how the product's interfaces, hardware profile, and operating characteristics work together in real deployment. Buyers often need this context to confirm compatibility with existing devices, expected performance in daily use, and whether installation will be straightforward for IT staff or end users.
Key Product Advantages
The PD2-103's primary advantage lies in its UPS maintenance bypass capability, which allows for continued network operation during UPS servicing without initiating unnecessary downtime. This feature is particularly valuable in environments where continuous uptime is essential.
These strengths make the product easier to deploy and manage in real environments, especially where reliability, usability, and day-to-day operational continuity matter. Notable benefits include Maintenance Bypass Functionality, Plug-and-Play Deployment.
Maintenance Bypass Functionality
Enables UPS maintenance without disrupting connected equipment, ensuring continuous power distribution to critical network components.
- Avoids unnecessary downtime
- Supports scheduled maintenance
- Maintains network uptime
Plug-and-Play Deployment
Designed for straightforward installation with the GXT 8/10kVA POD systems, reducing deployment time and complexity.
- Quick setup
- Compatible design
- Minimal configuration required
Deployment / Use Cases
The Liebert PD2-103 is specifically engineered for deployment with GXT 8/10kVA POD UPS systems in data center, server room, and network closet environments. Its combination of outlet types makes it suitable for mixed equipment installations where both standard and higher-power devices require reliable power distribution.
Ideal applications include server racks with a mix of computing equipment, networking devices, and storage systems. The maintenance bypass feature makes it particularly valuable for environments with strict uptime requirements, such as financial institutions, healthcare facilities, and telecommunications infrastructure where scheduled maintenance cannot compromise operational continuity.
This section brings together practical product details such as Plug/Connector Type, Plug/Connector Detail, Receptacle Type, Input Voltage, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
Physical Profile
With dimensions of 5.70 inches in height and 7.40 inches in width, the PD2-103 presents a compact footprint suitable for standard rack installations. The unit's 6.60-pound weight ensures it can be securely mounted without excessive load on rack rails or cabinets. The physical design prioritizes space efficiency while maintaining adequate ventilation and accessibility for connection management.
The physical profile is practical for deployment planning because the dimensions and weight are clearly defined: 5.70" (144.78 mm), 7.40" (187.96 mm), 6.60 lb (2993.71 g). This helps confirm rack, shelf, desk, or cabinet fit before installation.
- Width
- 7.40" (187.96 mm)
- Height
- 5.70" (144.78 mm)
- Weight
- 6.60 lb (2993.71 g)
Highlights
- 8-outlet PDU designed for GXT 8/10kVA POD UPS systems
- UPS maintenance bypass feature maintains uptime during servicing
- Hardwire terminal block input with 3W+G configuration
- Supports 120V and 230V AC input voltages
- Four NEMA 5-15R/20R outlets for standard equipment
- Four NEMA L6-30R outlets for higher-power devices
- Compact dimensions: 5.70" H x 7.40" W
- Plug-and-play deployment with compatible UPS systems
Specifications
| Specifications | |
|---|---|
| Manufacturer | Vertiv |
| Manufacturer Part Number | PD2-103 |
| Brand Name | Vertiv Liebert |
| Product Model | PD2-103 |
| Product Name | PD2-103 8-Outlets PDU |
| Product Type | PDU |
| Technical Information | |
| Plug/Connector Type | Hardwire Terminal Block 3W + G |
| Plug/Connector Detail | 1 x Hardwire Terminal Block 3W + G |
| Receptacle Type | NEMA 5-15R/20R,NEMA L6-30R |
| Receptacle Detail | 4 x NEMA 5-15R/20R,4 x NEMA L6-30R |
| Power Description | |
| Input Voltage | 120 V AC,230 V AC |
| Physical Characteristics | |
| Height | 5.70" (144.78 mm) |
| Width | 7.40" (187.96 mm) |
| Weight (Approximate) | 6.60 lb (2993.71 g) |
FAQ
What is the PD2-103's primary function with GXT UPS systems?
The PD2-103 serves as a power distribution unit specifically designed for Vertiv Liebert GXT 8/10kVA POD UPS systems. It distributes power from the UPS to connected equipment through eight outlets while providing a maintenance bypass feature that allows UPS servicing without disrupting power to critical devices.
What types of outlets does this PDU provide?
The PD2-103 offers eight total outlets: four NEMA 5-15R/20R receptacles suitable for standard IT equipment like servers, switches, and routers, and four NEMA L6-30R outlets designed for higher-power devices that require 30-amp connections. This combination supports mixed equipment environments effectively.
How does the maintenance bypass feature work?
The maintenance bypass functionality allows technicians to service the connected GXT UPS without interrupting power to equipment connected to the PDU. This is achieved through internal switching that maintains power distribution while the UPS is offline for maintenance, preventing unnecessary downtime in critical operations.
What input voltage does the PD2-103 support?
This PDU supports dual input voltages of 120V AC and 230V AC through its hardwire terminal block connection. The 3-wire plus ground configuration ensures proper grounding and electrical safety while providing flexibility for different electrical infrastructure setups in data centers and server rooms.
Is this PDU rack-mountable?
Yes, with dimensions of 5.70 inches in height and 7.40 inches in width, the PD2-103 is designed for standard rack installations. Its compact footprint and 6.60-pound weight make it suitable for mounting in server racks, network cabinets, and other enclosed environments where space optimization is important.
What equipment is compatible with this PDU?
The PD2-103 is specifically designed for use with Vertiv Liebert GXT 8kVA and 10kVA POD UPS systems. It can distribute power to any equipment with compatible plug types, including servers, network switches, storage devices, and other IT infrastructure that uses NEMA 5-15R/20R or L6-30R connections.
What power capacity is listed for this UPS?
Power specifications help show where Liebert PD2-103 8-Outlet PDU for GXT 8/10kVA POD - 208V/120V - 4 5-20R & - 4 L6-30R Outlets fits best, including the kind of load level, electrical environment, and backup role it is intended to support.
What runtime or backup profile is mentioned?
Liebert PD2-103 8-Outlet PDU for GXT 8/10kVA POD - 208V/120V - 4 5-20R & - 4 L6-30R Outlets should be evaluated around its backup-runtime profile, power capacity, and outlet layout so buyers can judge whether it fits workstation, networking, or edge-protection needs.