CyberPower PDU31003 Monitored Rack PDU - 16 NEMA 5-20R Outlets - 30A - 100-120V - 2U - 12 ft Cord - LCD - 3YR Warranty
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This monitored PDU operates with a 30A input current at 100-120V AC, 60 Hz, delivering consistent 120V AC output across all 16 NEMA 5-20R receptacles. The electrical design includes overload protection to safeguard connected equipment. Network management capabilities encompass IPv4 and IPv6 support with protocols including TCP/IP, UDP, SNMPv1/v3, HTTP/HTTPS, SSH, SSL/TLS, LDAP(S), RADIUS, Syslog, CLI, and Windows AD integration.
Physical specifications include a 2U rack height with dimensions of 3.50" height, 17.05" width, and 4.41" depth. The unit weighs approximately 8.80 lb and features a 12-foot power cord. Operating temperature range is 32°F to 113°F (0°C to 45°C) with storage tolerance from 5°F to 131°F (-15°C to 55°C). The PDU carries UL certification and is backed by a 3-year limited warranty.
Network Management Protocols
Supports comprehensive management through SNMPv1/v3, HTTP/HTTPS, SSH, Telnet, TCP/IP, UDP, LDAP(S), RADIUS, Syslog, and Windows AD for enterprise integration.
Key Product Advantages
The PDU31003 combines robust power distribution with advanced monitoring capabilities ideal for data centers, server rooms, and network closets. The integrated LCD display provides immediate visual feedback on power status, while network connectivity enables remote monitoring and alerting without requiring physical rack access.
For buyers comparing similar models, the strongest advantage is usually the balance between dependable day-to-day operation and a simpler rollout experience. That means less time spent troubleshooting fit, compatibility, or user adoption after installation, which is especially important for shared business environments and repeat purchasing decisions.
Advantages are also easier to justify when they translate into measurable operational value, such as less downtime, more consistent user experience, easier replacement planning, or better alignment with existing accessories and workflows. That practical value tends to matter more than broad marketing language when teams are standardizing purchases.
Deployment / Use Cases
This monitored PDU is engineered for environments where power visibility and distribution control are critical. The 16-outlet configuration supports dense server racks, network equipment installations, and telecommunications cabinets where multiple devices require reliable, monitored power.
Ideal deployment scenarios include enterprise data centers requiring power usage monitoring, colocation facilities needing remote management capabilities, broadcast and AV racks with multiple equipment pieces, and network operation centers where power alerting is essential for uptime. The unit's compatibility with standard network management systems allows integration into existing infrastructure monitoring platforms.
Data Center Rack Power
Distributes power to servers, switches, and storage units while providing monitoring data for capacity planning and alerting on power anomalies.
Network Equipment Cabinets
Powers multiple network devices with the ability to monitor consumption and receive alerts for proactive maintenance.
Physical Profile
Constructed with a durable metal housing in black finish, this PDU features a compact 2U rack-mountable design measuring 3.50" high, 17.05" wide, and 4.41" deep. The horizontal/vertical mounting flexibility accommodates various rack configurations, while the 12-foot power cord provides installation reach. Weighing 8.80 lb, the unit maintains a low profile in standard 19-inch racks without excessive depth requirements.
The physical profile is practical for deployment planning because the dimensions and weight are clearly defined: 2U, 17.05" (433.07 mm), 4.41" (112.01 mm), 8.80 lb (3991.61 g). This helps confirm rack, shelf, desk, or cabinet fit before installation.
- Width
- 17.05" (433.07 mm)
- Depth
- 4.41" (112.01 mm)
- Height
- 2U
- Weight
- 8.80 lb (3991.61 g)
- Length
- 12 ft (3.66 m)
Highlights
- 16 NEMA 5-20R outlets for multiple device connections
- 30A input current with 100-120V AC operating range
- 2U rack-mountable form factor with horizontal/vertical mounting
- Integrated LCD display for local status monitoring
- Network management via SNMP, HTTP/HTTPS, SSH, and Telnet
- Overload protection for connected equipment safety
- 12-foot power cord for flexible installation
- 3-year limited warranty with UL certification
- Metal construction in black finish for durability
- Operating temperature range of 32°F to 113°F (0°C to 45°C)
Specifications
| Specifications | |
|---|---|
| Manufacturer | CyberPower Systems, Inc |
| Manufacturer Part Number | PDU31003 |
| Brand Name | CyberPower |
| Product Series | Monitored PDU |
| Product Model | PDU31003 |
| Product Name | PDU31003 |
| Product Type | PDU |
| Technical Information | |
| PDU Type | Monitored |
| Plug/Connector Type | NEMA L5-30P |
| Plug/Connector Detail | 1 x NEMA L5-30P |
| Receptacle Type | NEMA 5-20R |
| Receptacle Detail | 16 x NEMA 5-20R |
| Protection Type | Overload Protection |
| Features | LCD Display |
| Power Description | |
| Input Voltage | 120 V AC |
| Input Voltage Range | 100 V AC - 120 V AC |
| Output Voltage | 120 V AC |
| Output Voltage Range | 100 V AC - 120 V AC |
| Input Current | 30 A |
| Input Frequency | 60 Hz |
| Management | |
| Management | IPv4 TCP/IP UDP SNMPv1 HTTP NTP DNS Telnet DHCP SMTP FTP IPv6 SNMPv3 HTTPs SSH SSL TLS LDAP(S) RADIUS Syslog CLI Windows AD |
| Remote Outlet Switching | No |
| Interfaces/Ports | |
| Network (RJ-45) | Yes |
| Physical Characteristics | |
| Color Family | Black |
| Product Color | Black |
| Product Material | Metal |
| Mounting Orientation | Horizontal/Vertical |
| Mount Type | Rack-mountable |
| Form Factor | Rack |
| Rack Height | 2U |
| Cord Length | 12 ft (3.66 m) |
| Height | 3.50" (88.90 mm) |
| Width | 17.05" (433.07 mm) |
| Depth | 4.41" (112.01 mm) |
| Length | 4.40" (111.76 mm) |
| Weight (Approximate) | 8.80 lb (3991.61 g) |
| Environmental Conditions | |
| Minimum Operating Temperature | 32°F (0°C) |
| Maximum Operating Temperature | 113°F (45°C) |
| Minimum Storage Temperature | 5°F (-15°C) |
| Maximum Storage Temperature | 131°F (55°C) |
| Miscellaneous | |
| Energy Star | No |
| Country of Origin | China |
| UL Listed | Yes |
| Warranty | |
| Limited Warranty | 3 Year |
User Manual
FAQ
What type of power input does this PDU require?
The PDU31003 requires a NEMA L5-30P plug connection providing 30A at 100-120V AC, 60 Hz. This single-phase input delivers 120V AC output to all 16 NEMA 5-20R outlets. The unit includes a 12-foot power cord for flexible installation.
How many devices can I connect to this power distribution unit?
This PDU provides 16 NEMA 5-20R outlets, allowing connection of up to 16 devices simultaneously. Each outlet delivers 120V AC power with overload protection. The total load should not exceed the 30A input capacity.
What rack space does this PDU occupy?
The PDU31003 occupies 2U of vertical rack space with dimensions of 3.50" height, 17.05" width, and 4.41" depth. It supports both horizontal and vertical mounting orientations within standard 19-inch racks, providing installation flexibility.
What monitoring capabilities does this PDU offer?
This monitored PDU features an integrated LCD display for local status viewing and network connectivity via RJ-45 for remote management. It supports SNMPv1/v3, HTTP/HTTPS, SSH, Telnet, and other protocols for power monitoring, alerting, and integration with network management systems.
Can I remotely manage individual outlets on this PDU?
No, the PDU31003 does not support remote outlet switching. It is a monitored PDU that provides power monitoring and alerting capabilities but does not include individual outlet control. For outlet-level control, consider a switched PDU model.
What certifications and warranty come with this power distribution unit?
The PDU31003 is UL Listed for safety compliance and carries a 3-year limited warranty from CyberPower. The metal construction meets industry standards for rack-mounted equipment, and the unit operates within a temperature range of 32°F to 113°F (0°C to 45°C).
What power capacity is listed for this UPS?
Power specifications help show where CyberPower PDU31003 100 - 120 VAC 30A Monitored - 16 Outlets, 12 ft, NEMA L5-30P, Horizontal, 2U, LCD, 3YR Warranty (PDU31003) fits best, including the kind of load level, electrical environment, and backup role it is intended to support.
What runtime or backup profile is mentioned?
CyberPower PDU31003 100 - 120 VAC 30A Monitored - 16 Outlets, 12 ft, NEMA L5-30P, Horizontal, 2U, LCD, 3YR Warranty (PDU31003) should be evaluated around its backup-runtime profile, power capacity, and outlet layout so buyers can judge whether it fits workstation, networking, or edge-protection needs.