Shipping included*
Exclusions
Additional shipping fees may apply in rare circumstances for deliveries outside standard service areas. In most cases, this only potentially affects shipments to the Northwest Territories and Yukon, as well as certain heavy or oversized items.
Tripp Lite by Eaton PDU3EVN10L2130 Monitored 45-Outlet PDU - 8. 6 kW - NEMA L21-30P - 6x C19 - 36x C13 - 3x NEMA 5-15/20R - Rack-Mountable 0U
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This PDU operates with a 230 V AC three-phase input and delivers 24 A input current. The output configuration supports both 120 V AC and 208 V AC voltages, making it compatible with a wide range of server, storage, and networking equipment. The 8.6 kW power rating ensures sufficient capacity for demanding rack environments.
Network management is implemented through the built-in LX Platform interface, supporting industry-standard protocols including IPv4, IPv6, HTTP, HTTPS, SMTP, SNMP versions 1-3, telnet, SSH, FTP, DHCP, and NTP. This enables integration with existing monitoring systems and provides detailed power metrics for capacity planning and alerting.
This section brings together practical product details such as PDU Type, Phase, Plug/Connector Type, Input Voltage, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
Key Product Advantages
This PDU combines high outlet density with advanced monitoring capabilities, providing both power distribution and visibility into rack power consumption. The comprehensive outlet mix accommodates equipment with different plug types, reducing the need for adapters and ensuring proper power delivery.
High-Density Outlet Configuration
With 45 total outlets including 6 C19, 36 C13, and 3 NEMA 5-15/20R receptacles, this PDU supports diverse equipment types in a single unit, maximizing rack space efficiency.
- 6 IEC C19 outlets for high-power equipment
- 36 IEC C13 outlets for standard servers
- 3 NEMA 5-15/20R outlets for peripheral devices
Advanced Monitoring Capabilities
The monitored design provides real-time power metrics through multiple network protocols, enabling proactive capacity management and early warning of potential overload conditions.
- Supports SNMP v1-3 for network integration
- HTTP/HTTPS for web-based management
- Email alerts via SMTP
Space-Optimized Rack Design
The vertical 0U mounting configuration occupies zero rack units of front-facing space, preserving valuable rack real estate for equipment while providing full power distribution capabilities.
- Vertical mounting saves rack space
- 0U design maximizes equipment capacity
- Includes mounting hardware and brackets
Deployment / Use Cases
The PDU3EVN10L2130 is ideal for data centers, server rooms, and network closets where high-density power distribution with monitoring is required. Its three-phase input and 8.6 kW capacity make it suitable for supporting multiple servers, storage arrays, and networking equipment in a single rack.
This PDU excels in environments requiring detailed power monitoring for capacity planning and operational efficiency. The network management capabilities enable integration with DCIM systems, providing visibility into power consumption trends and helping prevent overload conditions before they impact operations.
Data Center Server Racks
Support multiple high-density servers and storage systems with the 8.6 kW capacity and diverse outlet configuration, while monitoring power consumption for capacity planning.
Network Equipment Closets
Power switches, routers, and other networking gear with the appropriate outlet types while maintaining visibility into power usage through network management protocols.
Physical Profile
This PDU features a vertical rack-mount design with dimensions of 70" height × 2.17" width × 2.52" depth (1778 × 55.12 × 64.01 mm). The 0U rack height means it mounts vertically in standard server racks without consuming front-facing rack units. The unit weighs 13.50 lb (6123.50 g) and includes all necessary mounting hardware and brackets for secure installation.
The physical profile is practical for deployment planning because the dimensions and weight are clearly defined: 0U, 2.17" (55.12 mm), 2.52" (64.01 mm), 13.50 lb (6123.50 g). This helps confirm rack, shelf, desk, or cabinet fit before installation.
- Width
- 2.17" (55.12 mm)
- Depth
- 2.52" (64.01 mm)
- Height
- 0U
- Weight
- 13.50 lb (6123.50 g)
What's in the Box
The package includes all components needed for immediate deployment and operation.
Highlights
- 45 total outlets: 6 IEC C19, 36 IEC C13, 3 NEMA 5-15/20R
- 8.6 kW power capacity with three-phase 230 V AC input
- Monitored PDU with network management capabilities
- NEMA L21-30P input connector
- Output voltages: 120 V AC and 208 V AC
- Vertical 0U rack-mount design saves space
- Includes overload protection
- Supports multiple network protocols (SNMP, HTTP, SSH, etc.)
- Includes plug-lock insert sleeves for secure connections
- 2-year limited warranty
Specifications
| Specifications | |
|---|---|
| Manufacturer | Eaton Corporation |
| Manufacturer Part Number | PDU3EVN10L2130 |
| Brand Name | Tripp Lite series |
| Product Model | PDU3EVN10L2130 |
| Product Name | PDU3EVN10L2130 45-Outlet PDU |
| Product Type | PDU |
| Technical Information | |
| PDU Type | Monitored |
| Phase | Three Phase |
| Plug/Connector Type | NEMA L21-30P |
| Receptacle Type | IEC 60320 C19,IEC 60320 C13,NEMA 5-15/20R |
| Receptacle Detail | 6 x IEC 60320 C19,36 x IEC 60320 C13,3 x NEMA 5-15/20R |
| Protection Type | Overload Protection |
| Power Description | |
| Input Voltage | 230 V AC |
| Output Voltage | 120 V AC,208 V AC |
| Power Rating (Watt) | 8.60 kW |
| Input Current | 24 A |
| Management | |
| Management | Protocols: IPv4 IPv6 HTTP HTTPS SMTP SNMPv1 SNMPv2 SNMPv3 telnet SSH FTP DHCP NTP |
| Physical Characteristics | |
| Mounting Orientation | Vertical |
| Mount Type | Rack-mountable |
| Rack Height | 0U |
| Height | 70" (1778 mm) |
| Width | 2.17" (55.12 mm) |
| Depth | 2.52" (64.01 mm) |
| Weight (Approximate) | 13.50 lb (6123.50 g) |
| Miscellaneous | |
| Package Contents | PDU3EVN10L2130 48-Outlet PDU Built-in LX Platform interface Configuration Cable 45 x Plug-lock Insert Sleeves Rack-mounting Hardware Mounting Bracket Accessory Owner's Manual |
| Country of Origin | Taiwan |
| TAA Compliant | Yes |
| Environmentally Friendly | Yes |
| Environmental Compliance | Restriction of Hazardous Substances (RoHS) |
| Warranty | |
| Limited Warranty | 2 Year |
User Manual
FAQ
What is the total power capacity of this PDU?
The PDU3EVN10L2130 has a power rating of 8.60 kW (8,600 watts). This capacity is delivered through a three-phase 230 V AC input with 24 A current, making it suitable for high-density server racks and networking equipment requiring substantial power distribution.
How many outlets does this PDU have and what types are included?
This PDU features 45 total outlets with a mixed configuration: 6 IEC 60320 C19 outlets for high-power equipment, 36 IEC 60320 C13 outlets for standard servers and devices, and 3 NEMA 5-15/20R outlets for peripheral equipment. This diverse mix accommodates various equipment types without requiring adapters.
What does 'monitored' mean for this PDU?
Monitored indicates this PDU provides network-accessible power metrics and management capabilities. It includes a built-in LX Platform interface supporting protocols like SNMP (v1-3), HTTP/HTTPS, SSH, and others, allowing integration with monitoring systems for real-time power consumption tracking, alerting, and capacity planning.
What type of input connector does this PDU use?
The PDU uses a NEMA L21-30P input connector, which is a three-phase, 30-amp locking plug commonly used in commercial and data center environments. This connector type ensures secure power connection and is designed for three-phase power distribution systems.
How is this PDU mounted in a rack?
This PDU is designed for vertical rack mounting with a 0U footprint, meaning it mounts on the side or rear of the rack without consuming front-facing rack units. It includes all necessary mounting hardware, brackets, and supports vertical orientation to maximize space for equipment in the rack.
What protection features does this PDU include?
The PDU includes overload protection to safeguard connected equipment from excessive current draw. Combined with its monitored capabilities, it provides both physical protection and network-based alerting to help prevent power-related issues before they impact connected devices.
What power capacity is listed for this UPS?
The listed power specification is 8.60 kW, which helps position the unit for the right load level and installation role.
What voltage details are listed?
The listed power specification is 230 V AC, which helps position the unit for the right load level and installation role.