Shipping included*
Exclusions
Additional shipping fees may apply in rare circumstances for deliveries outside standard service areas. In most cases, this only potentially affects shipments to the Northwest Territories and Yukon, as well as certain heavy or oversized items.
Tripp Lite by Eaton PDUMVR30NETLX Eaton 24-Outlet Switched PDU - NEMA L5-30P - 120V AC - 3. 05 kW - 0U Vertical Rack-Mountable
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This switched PDU features single-phase power distribution with overload protection and supports an output voltage range of 100-127V AC. The unit provides 24 NEMA 5-15/20R receptacles, accommodating both 15A and 20A devices commonly found in IT environments.
Network management capabilities include support for multiple protocols including IPv4/IPv6, HTTP/HTTPS, SNMP versions 1-3, SSH, FTP, and DHCP for flexible integration into existing network infrastructures. The built-in LX platform interface enables granular outlet control and power monitoring through a web-based interface or network management systems.
This section brings together practical product details such as PDU Type, Phase, Plug/Connector Type, Input Voltage, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
A strong technical summary explains how the product's interfaces, hardware profile, and operating characteristics work together in real deployment. Buyers often need this context to confirm compatibility with existing devices, expected performance in daily use, and whether installation will be straightforward for IT staff or end users.
Key Product Advantages
The PDUMVR30NETLX combines high-density power distribution with intelligent management capabilities, reducing downtime and improving operational efficiency in critical IT environments.
Remote Outlet Control
Individually control each of the 24 outlets remotely to reboot unresponsive equipment, eliminating the need for physical access to servers or networking gear during troubleshooting.
- Web-based interface
- SNMP integration
- Scheduled power cycling
Space-Efficient Design
The vertical 0U mounting orientation occupies zero rack units of front or rear space, preserving valuable rack real estate for servers and other equipment while providing full power distribution capabilities.
- Zero rack units consumed
- Vertical installation
- Minimal footprint
Comprehensive Power Monitoring
Monitor input current, voltage, and power consumption at both the PDU level and individual outlet level, enabling capacity planning and identifying underutilized or overloaded circuits.
- Real-time monitoring
- Historical data logging
- Threshold alerts
Deployment / Use Cases
This switched PDU is engineered for data centers, server rooms, and network closets where reliable power distribution and remote management are essential for maintaining uptime and operational efficiency.
The unit's 24-outlet configuration supports high-density server racks, network equipment cabinets, and storage arrays, while the switched functionality enables controlled power sequencing and remote troubleshooting capabilities.
Data Center Server Racks
Deploy in standard 19" server racks to power multiple servers, switches, and storage devices while enabling remote reboot capabilities for unresponsive equipment without physical access to the data center floor.
Network Equipment Cabinets
Install in network closets and telecommunications rooms to distribute power to routers, switches, firewalls, and other networking gear, with the ability to remotely cycle power on individual devices during maintenance or troubleshooting.
Physical Profile
The PDUMVR30NETLX features a vertical mounting orientation with dimensions of 70" height, 2.20" width, and 2.04" depth, designed specifically for installation in standard 19" server racks. The 0U rack height means the unit occupies no rack units, mounting vertically alongside equipment without consuming front or rear rack space. The unit weighs approximately 9.94 pounds and includes cord retention brackets and cable ties for organized cable management.
- Width
- 2.20" (55.88 mm)
- Depth
- 2.04" (51.82 mm)
- Height
- 0U
- Weight
- 9.94 lb (4508.71 g)
What's in the Box
The package includes all necessary components for installation and operation of the power distribution unit.
Highlights
- 24 NEMA 5-15/20R outlets for flexible device connectivity
- 3.05 kW power capacity at 120V AC input
- Switched PDU with individual outlet control
- Vertical 0U rack-mount design saves rack space
- NEMA L5-30P input connector
- Network management via multiple protocols
- Overload protection for connected equipment
- Includes cord retention and cable management accessories
- TAA compliant for government deployments
- RoHS compliant and environmentally friendly
Specifications
| Specifications | |
|---|---|
| Manufacturer | Eaton Corporation |
| Manufacturer Part Number | PDUMVR30NETLX |
| Brand Name | Eaton |
| Product Model | PDUMVR30NETLX |
| Product Name | PDUMVR30NETLX 24-Outlet PDU |
| Product Type | PDU |
| Technical Information | |
| PDU Type | Switched |
| Phase | Single Phase |
| Plug/Connector Type | NEMA L5-30P |
| Receptacle Type | NEMA 5-15/20R |
| Receptacle Detail | 24 x NEMA 5-15/20R |
| Protection Type | Overload Protection |
| Power Description | |
| Input Voltage | 120 V AC |
| Output Voltage Range | 100 V AC - 127 V AC |
| Power Rating (Watt) | 3.05 kW |
| Input Current | 30 A |
| Management | |
| Management | Protocols: IPv4 IPv6 HTTP HTTPS SMTP SNMPv1 SNMPv2 SNMPv3 telnet SSH FTP DHCP NTP |
| Physical Characteristics | |
| Mounting Orientation | Vertical |
| Mount Type | Rack-mountable |
| Rack Height | 0U |
| Height | 70" (1778 mm) |
| Width | 2.20" (55.88 mm) |
| Depth | 2.04" (51.82 mm) |
| Weight (Approximate) | 9.94 lb (4508.71 g) |
| Miscellaneous | |
| Package Contents | PDUMVR30NETLX 24-Outlet PDU Built-in LX Platform Interface Configuration Cable Cord Retention Brackets 24 x Cable Ties Rack-mounting Hardware Mounting Bracket Accessory Owner's Manual |
| Country of Origin | Taiwan |
| TAA Compliant | Yes |
| Environmentally Friendly | Yes |
| Environmental Compliance | Restriction of Hazardous Substances (RoHS) |
| Warranty | |
| Limited Warranty | 2 Year |
User Manual
FAQ
What type of input connector does this PDU use?
The Eaton PDUMVR30NETLX uses a NEMA L5-30P input connector, which is a locking 30-amp plug designed for 120V AC power sources. This connector type provides secure electrical connection and is commonly used in data center and server room environments where reliable power distribution is critical.
How many devices can I connect to this power distribution unit?
This PDU provides 24 NEMA 5-15/20R outlets, allowing you to connect up to 24 devices simultaneously. The receptacles support both 15-amp and 20-amp plugs commonly found on servers, networking equipment, and storage devices, providing flexibility for mixed equipment environments.
What does 'switched PDU' mean for this unit?
A switched PDU allows remote control and monitoring of individual outlets through network connectivity. The PDUMVR30NETLX enables you to power cycle specific devices remotely via web interface or network management protocols, reboot locked equipment without physical access, monitor power consumption per outlet, and schedule power operations for maintenance windows.
How is this PDU mounted in a server rack?
This unit features vertical 0U rack mounting, meaning it installs vertically in a standard 19-inch server rack without consuming any rack units of front or rear space. The mounting hardware included in the package allows secure installation alongside your equipment, optimizing rack space utilization while providing full power distribution capabilities.
What network management protocols are supported?
The PDUMVR30NETLX supports comprehensive network management protocols including IPv4 and IPv6, HTTP and HTTPS for web interface access, SMTP for email alerts, SNMP versions 1-3 for network monitoring integration, telnet and SSH for command-line access, FTP for firmware updates, DHCP for automatic IP assignment, and NTP for time synchronization.
What power protection features does this PDU include?
This power distribution unit includes overload protection to safeguard connected equipment from excessive current draw. The unit monitors power consumption and will protect against overload conditions that could damage equipment or create safety hazards. Combined with the switched functionality, this provides both physical protection and operational control for your critical IT infrastructure.
What power capacity is listed for this UPS?
The listed power specification is 3.05 kW, which helps position the unit for the right load level and installation role.
What voltage details are listed?
The listed power specification is 120 V AC, which helps position the unit for the right load level and installation role.