CyberPower PR3000RT2UC Smart App Sinewave UPS - 3000VA/3000W Line-Interactive - 2U Rack/Tower - 9 Outlets - Sine Wave Output - 120V

SKU: PR3000RT2UC
UPC: 0649532935529
(No reviews) Write a Review
MSRP: $2,271.95
$2,346.95
$2,060.95
Save: $211.00 (8.99%)
Warranty Information: 3 Year
Condition: New
Width: 43.43 (cm)
Height: 8.64 (cm)
Depth: 50.04 (cm)

Ask for ETA! 🗨️

Logo cards
B2B Pricing

Business volume discounts

IT Experts

Technical guidance

IT Configuration

Preparation & staging

Canada Stock

QC · ON · AB · BC

Product Features

Description

Product Overview

The CyberPower PR3000RT2UC Smart App Sinewave UPS delivers robust line-interactive power protection for critical IT infrastructure. With 3000VA/3000W capacity and pure sine wave output, this unit ensures clean, stable power for sensitive server, storage, and networking equipment.

Designed for both rack and tower deployment, the 2U form factor provides installation flexibility in data centers, server rooms, and network closets. The unit features automatic voltage regulation (AVR) to correct brownouts and overvoltages without switching to battery, extending runtime and battery life.

Nine NEMA 5-20R outlets provide ample connectivity, with four designated as critical load outlets for essential equipment. The integrated LCD display offers real-time status monitoring, while comprehensive network management capabilities enable remote monitoring and control.

Relevant product facts for this section include AVR: Yes, Plug/Connector Type: NEMA L5-30P, Receptacle Type: NEMA 5-20R, Load Capacity (VA): 3 kVA. When those details are considered together, they give buyers a clearer picture of how the product is equipped, how it connects, and what kind of day-to-day role it is meant to support.

Power
3 kVA
Power Capacity
Outlets: 9120 V AC
Power Capacity & Topology
Load Capacity3000 VA / 3000 W
TopologyLine-interactive UPS
Waveform TypeSine Wave
Input & Output Specifications
Input Voltage120 V AC
Output Voltage100-120 V AC
Frequency50/60 Hz
Runtime & Battery
Half-Load Runtime5.5 minutes
Full-Load Runtime1.5 minutes
Battery Configuration4 x 12V sealed lead-acid
Physical & Installation
Form Factor2U Rack/Tower
Outlets9 total (4 critical load)
Weight76.5 lb

Technical Overview

This line-interactive UPS maintains a 1.0 output power factor for efficient power delivery to modern server power supplies. The input voltage range extends from 75-149 VAC, providing wide tolerance for unstable utility power. Output voltage remains within ±5% of nominal during normal operation.

Management interfaces include USB, serial, EPO, and HID-compliant USB ports for integration with power management software. SNMP/HTTP remote monitoring, relay-MS card support, and dry contact alarms enable enterprise-grade monitoring and notification. The unit generates 57.5 dB(A) of sound during battery operation and dissipates 192.5 BTU/h of heat.

Transfer Time6 ms
Surge Protection2430 J
Recharge Time3 hours

Battery System

Four 12V sealed lead-acid batteries with 9000 mAh total capacity provide backup power. The hot-swappable design allows battery replacement without system downtime, and the typical recharge time is three hours.

  • User-replaceable batteries
  • Low battery and fault alarms
  • Battery test function
AVREMI/RFI FilterCircuit BreakerHot-Swappable BatteriesEnergy Star CertifiedRoHS Compliant

Key Product Advantages

The PR3000RT2UC combines enterprise-grade power protection with practical deployment features. Pure sine wave output ensures compatibility with active PFC power supplies found in modern servers and network equipment, preventing shutdowns or damage during backup operation.

Intelligent Power Management

GreenPower UPS™ bypass technology reduces energy consumption during normal operation. The unit automatically bypasses internal components when utility power is stable, lowering operating costs and heat generation.

  • Energy Star certification
  • Reduced thermal output
  • Lower electricity consumption

Comprehensive Protection

Beyond battery backup, the unit provides multi-stage surge protection, EMI/RFI noise filtering, and overload protection. The circuit breaker prevents damage from excessive current draw.

  • 2430 joule surge rating
  • 6 ms transfer time
  • Overload and fault indicators

Deployment / Use Cases

This UPS is engineered for environments requiring reliable power continuity for critical systems. The 3000VA capacity supports multiple devices simultaneously, making it suitable for consolidated server racks or distributed network equipment.

In data center applications, the 2U rack-mount design optimizes space utilization while providing sufficient runtime for graceful shutdowns or transfer to generator power. The rack ears are included for standard 19-inch rack installation.

Server & Storage Protection

Protect rack-mounted servers, storage arrays, and network switches from power anomalies. The sine wave output ensures compatibility with enterprise server power supplies, while the 5.5-minute half-load runtime allows time for controlled shutdowns.

  • Supports multiple 1U/2U servers
  • Compatible with SAN/NAS storage
  • Network management integration

VoIP & Telecommunication Systems

Maintain voice communication during power interruptions. The unit provides clean power to VoIP phones, PBX systems, and network switches, ensuring business continuity for critical communication infrastructure.

  • Stable power for sensitive electronics
  • Supports PoE network equipment
  • Remote monitoring capabilities

Physical Profile

The black chassis measures 3.4"H × 17.1"W × 19.7"D (86.36 × 434.34 × 500.38 mm), fitting standard 19-inch racks at 2U height. At 76.5 pounds, the unit requires proper rack mounting hardware and consideration of weight distribution in multi-unit installations.

The front panel features an LCD display, status LEDs, and control buttons for easy operation. The 10-foot NEMA L5-30P input cord provides flexibility in positioning relative to power sources. Operating temperature ranges from 32°F to 104°F (0°C to 40°C) with up to 95% humidity tolerance.

Color
Black
Dimensions
Width
17.10" (434.34 mm)
Depth
19.70" (500.38 mm)
Height
3.40" (86.36 mm)
Weight
57.5 dB(A)
Length
10 ft (3.05 m)
[custom-highlights]

Highlights

  • 3000VA/3000W line-interactive UPS with pure sine wave output
  • 2U rack/tower design for flexible deployment in server rooms
  • 9 total outlets with 4 critical load outlets for essential equipment
  • 5.5-minute runtime at half load (1.5 minutes at full load)
  • Automatic voltage regulation (AVR) corrects brownouts without battery use
  • Hot-swappable batteries allow replacement without downtime
  • SNMP/HTTP remote monitoring for enterprise management
  • Energy Star certified with GreenPower UPS™ energy saving technology
  • 3-year limited warranty from CyberPower
  • RoHS compliant and environmentally friendly design
[/custom-highlights][custom-specifications]

Specifications

Specifications
ManufacturerCyberPower Systems, Inc
Manufacturer Part NumberPR3000RT2UC
Brand NameCyberPower
Product SeriesSmart App Sinewave
Product ModelPR3000RT2UC
Product NamePR3000RT2UC Smart App Sinewave UPS Systems
Product TypeLine-interactive UPS
Technical Information
AVRYes
Plug/Connector TypeNEMA L5-30P
Receptacle TypeNEMA 5-20R
Receptacle Detail8 x NEMA 5-20R
Number of Battery & Surge Outlets9
Number of Critical Load Outlets4
Overload ProtectionYes
Cord Length10 ft (3.05 m)
Transfer Time6 ms
EMI/RFI Noise FilterYes
Energy SavingGreenPower UPS™ Bypass Technology
Application/UsageServer,Storage Device,VoIP,Network Device,Telecommunication,Equipment
Power Description
Load Capacity (VA)3 kVA
Load Capacity (Watt)3 kW
Input Voltage120 V AC
Input Voltage Range100 V AC - 120 V AC,75 V AC - 149 V AC
Output Voltage100 V AC,110 V AC,120 V AC
Input Frequency50 Hz,60 Hz
Output Frequency50 Hz,60 Hz
Waveform TypeSine Wave
Surge Energy Rating2430 J
Circuit BreakerYes
Output Power Factor1
Display & Graphics
DisplayLCD
Management
Network ManagementSNMP/HTTP Remote Monitoring,Relay-MS Card,Dry Contact
AlarmBattery Mode,Low Battery,Overload,Over-charge,Fault
Controls/Indicators
Status IndicatorsLED Indicators: Power On Line Mode Battery Mode Fault
Interfaces/Ports
Serial PortYes
USBYes
EPO PortYes
USB (HID Compliant) PortYes
Battery Information
Number of Batteries4
Battery CharacteristicsSealed
Battery ChemistryLead Acid
Battery Size12V
Battery Capacity9000 mAh
Backup/Run Time (Full Load)1.50 Minute
Backup/Run Time (Half Load)5.50 Minute
Hot SwappableYes
Typical Battery Recharge Time3 Hour
Replaceable BatteryYes
Environmental Conditions
Maximum Operating Elevation9842.52 ft (3000000 mm)
Maximum Storage Elevation49209.32 ft (14999000 mm)
Storage Temperature5°F (-15°C) - 113°F (45°C)
Operating Humidity95%
Storage Relative Humidity95%
Minimum Operating Temperature32°F (0°C)
Maximum Operating Temperature104°F (40°C)
Sound Emission (A-Weighted)57.5 dB(A)
Thermal Dissipation192.50 BTU/h
Physical Characteristics
Product ColorBlack
Height3.40" (86.36 mm)
Width17.10" (434.34 mm)
Depth19.70" (500.38 mm)
Rack Height2U
Form FactorRack/Tower
Weight (Approximate)76.50 lb (34699.82 g)
Miscellaneous
Energy StarYes
Environmentally FriendlyYes
Environmental ComplianceRestriction of Hazardous Substances (RoHS)
Warranty
Limited Warranty3 Year
[/custom-specifications][custom-user-manual]

User Manual

This section contains official documentation provided by the manufacturer, including product manuals, brochures, and supplementary materials.
[/custom-user-manual][custom-faq]

FAQ

What is the difference between VA and watt ratings on this UPS?

The 3000VA rating represents the apparent power capacity, while the 3000W rating indicates the actual power delivery capability. With a 1.0 output power factor, this UPS delivers 3000 watts of real power, making it efficient for modern server power supplies that draw close to their VA rating in watts.

Can this UPS be used in both rack and tower configurations?

Yes, the PR3000RT2UC supports both 2U rack mounting and standalone tower deployment. Rack ears are included for standard 19-inch rack installation. In tower mode, the unit sits horizontally on a stable surface, making it suitable for locations without rack infrastructure.

How many devices can I connect to the 9 outlets?

All nine NEMA 5-20R outlets provide battery backup and surge protection. Four outlets are designated as critical load outlets with longer runtime support. The total connected load should not exceed 3000VA/3000W. Typical deployments include servers, storage, network switches, and VoIP equipment.

What management options are available for remote monitoring?

The UPS supports SNMP/HTTP remote monitoring via network interface, relay-MS card for external notification, and dry contact alarms. Local interfaces include USB, serial, EPO, and HID-compliant USB ports for integration with power management software like CyberPower PowerPanel.

Are the batteries user-replaceable and hot-swappable?

Yes, the four 12V sealed lead-acid batteries are both user-replaceable and hot-swappable. This design allows battery replacement without powering down connected equipment. Typical battery recharge time is three hours after a complete discharge.

What is the significance of sine wave output for server equipment?

Pure sine wave output ensures compatibility with active power factor correction (PFC) power supplies found in modern servers, storage arrays, and network equipment. Simulated sine wave or stepped approximations can cause shutdowns, equipment damage, or reduced efficiency during battery operation.

[/custom-faq]
Volume Discounts
Qty Price Available
Match Price Request

Found a lower price? Send us the link and we will do our best to match or beat it.

Request received. We will reply within 24 hours.
Fleet Network
Wholesale & B2B
Partner with Us

Looking to buy in bulk? We offer competitive pricing, dedicated support, and custom solutions for businesses of all sizes.

Volume Discounts

Tiered pricing structure designed to maximize your margins as you grow.

Dedicated Account Manager

Direct access to a specialist who understands your business needs.

Fast & Reliable Shipping

Priority processing and discounted shipping rates for bulk orders.

Request a Quote
Thank you!
Your request has been sent successfully.
CyberPower PR3000RT2UC Smart App Sinewave UPS - 3000VA/3000W Line-Interactive - 2U Rack/Tower - 9 Outlets - Sine Wave Output - 120V
MSRP: $2,271.95
$2,346.95
$2,060.95
Save: $211.00 (8.99%)
Out of stock