Raritan PX3-1135A1U-E2N1Q1V2 50-Outlet Metered Rack PDU - 23 kW/23 kVA - 415V AC Three Phase - Clipsal 56P532 Input - 0U Vertical Mount
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This PDU operates on three-phase 415V AC input power with 32A current rating, converting to 240V AC output across all 50 receptacles. The 60Hz frequency compatibility ensures stable operation in standard North American power environments.
Network connectivity via RJ-45 enables remote management through multiple protocols including HTTP(s), SSH, Telnet, SNMP v2/v3, SMTP, JSON-RPC, and Modbus over TCP. While remote outlet switching is not supported, the comprehensive monitoring capabilities through Power IQ integration provide detailed power analytics and alerting.
This section brings together practical product details such as PDU Type, Phase, Plug/Connector Type, Input Voltage, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
A strong technical summary explains how the product's interfaces, hardware profile, and operating characteristics work together in real deployment. Buyers often need this context to confirm compatibility with existing devices, expected performance in daily use, and whether installation will be straightforward for IT staff or end users.
Key Product Advantages
High-Density Power Distribution
With 50 IEC C13 outlets in a vertical 0U form factor, this PDU maximizes rack space utilization while delivering 23 kW capacity for power-intensive equipment deployments.
- 50 outlets in minimal rack space
- 23 kW/23 kVA capacity
- Vertical 0U mounting profile
Comprehensive Power Monitoring
The integrated metering with LCD display provides real-time visibility into power consumption, enabling proactive load balancing and capacity planning.
- Onboard LCD display
- Real-time load monitoring
- Historical power data tracking
Enterprise Management Integration
Multiple management protocols and Power IQ compatibility allow seamless integration into existing data center infrastructure management systems.
- SNMP v2/v3 support
- Modbus TCP integration
- Power IQ compatible
Deployment / Use Cases
This PDU is engineered for data center environments where high-density server deployments require reliable, monitored power distribution. The 50-outlet configuration supports blade server enclosures, network equipment racks, and storage arrays where maximizing outlet density per rack unit is critical.
The three-phase 415V AC input makes this unit suitable for larger data center installations with three-phase power infrastructure. The vertical 0U mounting preserves valuable horizontal rack space for equipment while providing full-length power distribution along the rack's vertical rails.
This section brings together practical product details such as PDU Type, Phase, Plug/Connector Type, Input Voltage, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
Data Center Server Racks
Ideal for high-density server deployments where multiple 1U/2U servers require individual power connections with monitoring capabilities.
Network Equipment Rooms
Supports networking gear, switches, and communication equipment with secure power connections and load monitoring for capacity planning.
Physical Profile
The PDU features a black powder coat finish with dimensions optimized for vertical rack mounting. At 80.50" height, 2.10" width, and 2.60" depth, the unit provides full rack-height coverage while maintaining a slim profile. The 9.8 ft (3 m) input cord offers flexible installation options, and the 20.94 lb weight ensures stable mounting without excessive rack loading.
- Width
- 2.10" (53.34 mm)
- Depth
- 2.60" (66.04 mm)
- Height
- 0U
- Weight
- 20.94 lb (9500 g)
- Length
- 9.8 ft (3 m)
Highlights
- 50 IEC C13 outlets for high-density equipment deployments
- 23 kW/23 kVA power capacity with three-phase 415V AC input
- Vertical 0U rack mounting preserves horizontal rack space
- Onboard LCD display for real-time load monitoring
- SecureLock receptacles prevent accidental disconnection
- Comprehensive network management via SNMP, HTTP(s), Modbus TCP
- Clipsal 56P532 (4P5W) input connector configuration
- Black powder coat finish for durable data center use
- Branch circuit and overload protection for equipment safety
- 2-year limited warranty with RoHS environmental compliance
Specifications
| Specifications | |
|---|---|
| Manufacturer | Legrand Group |
| Manufacturer Part Number | PX3-1135A1U-E2N1Q1V2 |
| Brand Name | Raritan |
| Product Series | PX3 |
| Product Model | PX3-1135A1U-E2N1Q1V2 |
| Product Name | PX3-1135A1U-E2N1Q1V2 50-Outlets PDU |
| Product Type | PDU |
| Technical Information | |
| PDU Type | Metered |
| Phase | Three Phase |
| Plug/Connector Type | Clipsal 56P532 (4P5W) |
| Receptacle Type | IEC 60320 C13 |
| Receptacle Detail | 50 x IEC 60320 C13 |
| Protection Type | Branch Circuit,Overload Protection |
| Locking Receptacles | SecureLock |
| Features | LCD Display,Onboard Display |
| Load Capacity (VA) | 23 kW |
| Power Description | |
| Input Voltage | 415 V AC |
| Output Voltage | 240 V AC |
| Power Rating (VA) | 23 kVA |
| Input Current | 32 A |
| Input Frequency | 60 Hz |
| Management | |
| Management | HTTP(s) SSH Telnet RS-232 (Serial) Power IQ SNMP version v2/v3 SMTP JSON-RPC Modbus over TCP |
| Remote Outlet Switching | No |
| Interfaces/Ports | |
| Network (RJ-45) | Yes |
| Physical Characteristics | |
| Product Color | Black Powder Coat |
| Mounting Orientation | Vertical |
| Mount Type | Rack-mountable |
| Rack Height | 0U |
| Cord Length | 9.8 ft (3 m) |
| Height | 80.50" (2044.70 mm) |
| Width | 2.10" (53.34 mm) |
| Depth | 2.60" (66.04 mm) |
| Weight (Approximate) | 20.94 lb (9500 g) |
| Environmental Conditions | |
| Maximum Operating Temperature | 140°F (60°C) |
| Maximum Operating Humidity | 85% |
| Miscellaneous | |
| Environmental Compliance | Restriction of Hazardous Substances (RoHS) |
| Warranty | |
| Limited Warranty | 2 Year |
User Manual
FAQ
What is the power capacity of this PDU?
This Raritan PDU delivers 23 kilowatts (23 kW) of power capacity, equivalent to 23 kilovolt-amperes (23 kVA). It operates on three-phase 415V AC input power with 32A current rating, providing 240V AC output across all 50 outlets for high-density equipment deployments.
How many outlets does this PDU have and what type are they?
The PDU features 50 IEC 60320 C13 outlets, which are standard connectors for server and networking equipment power cords. All outlets include SecureLock technology to prevent accidental disconnection in vibration-prone environments.
What input connector does this PDU use?
This unit utilizes a Clipsal 56P532 (4P5W) input connector, which is a specific Australian/NZ style connector for three-phase power applications. The 9.8 ft (3 m) input cord provides installation flexibility in data center environments.
How is this PDU mounted in a rack?
The PDU is designed for vertical 0U mounting along the side rails of a standard 19-inch rack. This mounting orientation preserves valuable horizontal rack space for equipment while providing full-height power distribution. The slim 2.10" width ensures minimal intrusion into the rack's usable space.
What management capabilities does this metered PDU offer?
The PDU supports comprehensive network management through multiple protocols including HTTP(s), SSH, Telnet, SNMP version 2 and 3, SMTP, JSON-RPC, and Modbus over TCP. The onboard LCD display provides local monitoring, while Power IQ integration enables detailed power analytics and reporting.
What protection features are included with this PDU?
This PDU includes branch circuit protection and overload protection to safeguard connected equipment. The SecureLock receptacles prevent accidental disconnections, and the unit is RoHS compliant for environmental safety. It operates within 140°F (60°C) maximum temperature and 85% maximum humidity conditions.
What power capacity is listed for this UPS?
The listed power specification is 23 kW, which helps position the unit for the right load level and installation role.
How many outlets are available?
The product includes No, which helps buyers understand how many connected devices it can support in its intended deployment.