Shipping included*
Exclusions
Additional shipping fees may apply in rare circumstances for deliveries outside standard service areas. In most cases, this only potentially affects shipments to the Northwest Territories and Yukon, as well as certain heavy or oversized items.
Raritan PX3-1465U-V2 Metered PDU - 50 Outlets - 38 C13 - 12 C19 - 16. 6 kVA - 230V AC - Rack-Mount 0U
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This metered PDU features precise power monitoring capabilities with real-time load display, allowing administrators to track power consumption at the circuit level. The unit provides branch circuit and overload protection to safeguard connected equipment, while SecureLock receptacles ensure power connections remain secure in vibration-prone environments.
Network connectivity via RJ-45 enables remote monitoring and management integration, though individual outlet switching is not supported. The PDU operates at 60 Hz frequency and maintains performance within specified environmental limits of 140°F maximum temperature and 85% maximum humidity.
This section brings together practical product details such as PDU Type, Phase, Plug/Connector Type, Input Voltage, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
A strong technical summary explains how the product's interfaces, hardware profile, and operating characteristics work together in real deployment. Buyers often need this context to confirm compatibility with existing devices, expected performance in daily use, and whether installation will be straightforward for IT staff or end users.
Key Product Advantages
The PX3-1465U-V2 combines high-density power distribution with detailed monitoring capabilities in a space-efficient form factor. Its metered design provides the visibility needed for capacity planning and power optimization without the complexity of switched PDUs.
High Outlet Density
With 50 outlets (38 C13 and 12 C19), this PDU supports mixed equipment configurations in a single rack, reducing the need for multiple power strips and simplifying cable management.
- 38 IEC 60320 C13 outlets
- 12 IEC 60320 C19 outlets
- Mixed configuration support
Space-Efficient Design
The 0U vertical mounting preserves valuable rack space for equipment while providing full-length power distribution along the rack's side or rear.
- Zero rack units consumed
- Vertical mounting orientation
- Compact 2.3" width profile
Comprehensive Protection
Branch circuit and overload protection mechanisms work together to prevent electrical faults from damaging connected equipment, while SecureLock receptacles maintain reliable connections.
- Branch circuit protection
- Overload protection
- SecureLock receptacle system
Deployment / Use Cases
This metered PDU is engineered for environments where power monitoring and high-density distribution are priorities. Its three-phase design and substantial capacity make it suitable for supporting multiple servers, storage arrays, and networking equipment in a single rack.
The unit excels in data center cabinets, server rooms, and network closets where administrators need to monitor power consumption for capacity planning and billing purposes. The CS8365C (3P4W) plug type and 230V AC input voltage align with standard commercial three-phase power installations.
Data Center Racks
Ideal for server racks containing multiple 1U and 2U servers, storage systems, and network switches that require both C13 and C19 power connections.
Equipment Monitoring
Perfect for environments where power usage tracking is necessary for capacity management, cost allocation, or efficiency reporting without requiring individual outlet control.
Physical Profile
The PDU features a slim 2.3" width profile that fits neatly in standard rack side channels or rear mounting positions. With dimensions of 78" height, 2.3" width, and 3.1" depth, the unit provides full-rack coverage while maintaining a minimal footprint. The black powder coat finish offers durability and blends with standard rack equipment aesthetics.
- Width
- 2.30" (58.42 mm)
- Depth
- 3.10" (78.74 mm)
- Height
- 0U
- Weight
- 26.46 lb (12000 g)
- Length
- 9.8 ft (3 m)
Highlights
- 50 total outlets with 38 C13 and 12 C19 configurations
- 16.6 kVA power rating with 14.4 kW load capacity
- Three-phase power with 230V AC input and 208V AC output
- 0U vertical rack mounting preserves equipment space
- Onboard LCD display for real-time power monitoring
- SecureLock receptacles prevent accidental disconnection
- Network connectivity via RJ-45 for remote management
- Branch circuit and overload protection systems
- Black powder coat finish for durability
- 2-year limited warranty with RoHS compliance
Specifications
| Specifications | |
|---|---|
| Manufacturer | Legrand Group |
| Manufacturer Part Number | PX3-1465U-V2 |
| Brand Name | Raritan |
| Product Series | PX3 |
| Product Model | PX3-1465U-V2 |
| Product Name | PX3-1465U-V2 50-Outlets PDU |
| Product Type | PDU |
| Technical Information | |
| PDU Type | Metered |
| Phase | Three Phase |
| Plug/Connector Type | CS8365C (3P4W) |
| Receptacle Type | IEC 60320 C13,IEC 60320 C19 |
| Receptacle Detail | 38 x IEC 60320 C13,12 x IEC 60320 C19 |
| Protection Type | Branch Circuit,Overload Protection |
| Locking Receptacles | SecureLock |
| Features | LCD Display,Onboard Display |
| Load Capacity (VA) | 14.40 kW |
| Power Description | |
| Input Voltage | 230 V AC |
| Input Voltage Range | 208 V AC - 240 V AC |
| Output Voltage | 208 V AC |
| Output Voltage Range | 208 V AC - 240 V AC |
| Power Rating (VA) | 16.60 kVA |
| Input Current | 50 A |
| Input Frequency | 60 Hz |
| Management | |
| Remote Outlet Switching | No |
| Interfaces/Ports | |
| Network (RJ-45) | Yes |
| Physical Characteristics | |
| Product Color | Black Powder Coat |
| Mounting Orientation | Vertical |
| Mount Type | Rack-mountable |
| Rack Height | 0U |
| Cord Length | 9.8 ft (3 m) |
| Height | 78" (1981.20 mm) |
| Width | 2.30" (58.42 mm) |
| Depth | 3.10" (78.74 mm) |
| Weight (Approximate) | 26.46 lb (12000 g) |
| Environmental Conditions | |
| Maximum Operating Temperature | 140°F (60°C) |
| Maximum Operating Humidity | 85% |
| Miscellaneous | |
| Environmental Compliance | Restriction of Hazardous Substances (RoHS) |
| Warranty | |
| Limited Warranty | 2 Year |
User Manual
FAQ
What is the total power capacity of this PDU?
The Raritan PX3-1465U-V2 has a power rating of 16.60 kVA with a load capacity of 14.40 kW. It supports three-phase power with 50A input current, making it suitable for high-density server racks and equipment cabinets requiring substantial power distribution.
How many outlets does this PDU have and what types?
This PDU provides 50 total outlets: 38 IEC 60320 C13 outlets and 12 IEC 60320 C19 outlets. This mixed configuration supports both standard server power cords (C13) and higher-power equipment requiring C19 connections, allowing flexible equipment deployment in a single rack.
What voltage does this PDU support?
The PDU accepts input voltage of 230V AC with a range of 208-240V AC, and delivers output voltage of 208V AC with the same 208-240V AC range. This three-phase configuration is standard for North American commercial power installations in data centers and server rooms.
How is this PDU mounted in a rack?
The PDU uses 0U vertical mounting, meaning it consumes no rack units of front-facing space. It mounts vertically along the side or rear of the rack with dimensions of 78" height × 2.3" width × 3.1" depth. This space-efficient design maximizes equipment capacity within the rack.
Does this PDU support remote management?
Yes, the PDU includes network connectivity via RJ-45 for remote monitoring and management integration. However, it does not support individual remote outlet switching. The onboard LCD display provides local power monitoring, while network connectivity enables integration with power management systems.
What protection features does this PDU include?
The PDU provides both branch circuit protection and overload protection to safeguard connected equipment. It also features SecureLock receptacles that lock power cords in place to prevent accidental disconnection in environments with vibration or cable movement.
What power capacity is listed for this UPS?
The listed power specification is 14.40 kW, which helps position the unit for the right load level and installation role.
How many outlets are available?
The product includes No, which helps buyers understand how many connected devices it can support in its intended deployment.