Shipping included*
Exclusions
Additional shipping fees may apply in rare circumstances for deliveries outside standard service areas. In most cases, this only potentially affects shipments to the Northwest Territories and Yukon, as well as certain heavy or oversized items.
Raritan PX3-1862-C5 Metered Rack PDU - 42 Outlets - 36x C13 - 6x C19 - 5. 80 kVA - NEMA L6-30P - 230V AC
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This metered PDU operates on a single-phase electrical system with an input voltage range of 200-240V AC and delivers a stable 208V AC output across the same range. The 30-amp input circuit supports the full 5.80 kVA power rating, enabling it to handle substantial loads from connected servers, switches, and storage devices.
The unit incorporates branch circuit and overload protection to safeguard connected equipment against electrical faults. SecureLock receptacles provide a positive locking connection for power cords, preventing accidental disconnection in high-vibration environments.
This section brings together practical product details such as PDU Type, Phase, Plug/Connector Type, Input Voltage, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
A strong technical summary explains how the product's interfaces, hardware profile, and operating characteristics work together in real deployment. Buyers often need this context to confirm compatibility with existing devices, expected performance in daily use, and whether installation will be straightforward for IT staff or end users.
Key Product Advantages
The PX3-1862-C5 combines high-density power distribution with intelligent monitoring capabilities, giving IT managers the tools to optimize power usage and prevent overloads before they cause downtime. The integrated LCD display provides at-a-glance status without requiring network access, while the comprehensive management interface enables remote monitoring and integration with existing data center infrastructure.
High-Density Outlet Configuration
With 36 IEC C13 and 6 IEC C19 outlets, this PDU supports a mixed environment of servers, network gear, and storage devices, maximizing power distribution in limited rack space.
- 36 standard C13 outlets
- 6 high-power C19 outlets
- 42 total connections
Comprehensive Management Interface
Network connectivity via RJ-45 enables management through HTTP(s), SSH, Telnet, SNMP v2/v3, and other protocols, allowing integration with Power IQ and other DCIM solutions.
- HTTP(s) and SSH access
- SNMP v2/v3 support
- JSON-RPC and Modbus TCP
Deployment / Use Cases
This metered PDU is designed for deployment in standard 19-inch server racks within data centers, colocation facilities, and enterprise server rooms where power monitoring and high-density distribution are required. The 42-outlet configuration makes it ideal for fully populated racks containing multiple 1U and 2U servers, network switches, and storage arrays.
The unit's monitoring capabilities support capacity planning by tracking power usage trends over time, helping organizations right-size their power infrastructure and avoid circuit overloads. IT teams can use the real-time data to balance loads across circuits and identify underutilized equipment for potential consolidation or decommissioning.
Data Center Power Distribution
Deploy in standard server racks to distribute and monitor power to multiple servers, network switches, and storage devices from a single power source with visibility into consumption patterns.
Remote Site Management
The network management capabilities allow IT staff to monitor power conditions at remote locations without physical access, receiving alerts for abnormal conditions or approaching capacity limits.
Physical Profile
The PDU features a slim, vertical design with dimensions of 2.10" wide by 2.20" deep, allowing it to mount neatly in standard 19-inch rack enclosures without consuming valuable equipment space. At 70.10" in height, it provides full vertical coverage in standard rack configurations. The black powder coat finish offers durability and a professional appearance that blends with typical data center equipment.
- Width
- 2.10" (53.34 mm)
- Depth
- 2.20" (55.88 mm)
- Height
- 70.10" (1780.54 mm)
- Weight
- 13.89 lb (6300 g)
- Length
- 9.8 ft (3 m)
Highlights
- 42 total outlets with 36 IEC C13 and 6 IEC C19 receptacles
- 5.80 kVA power rating with 5 kW load capacity
- Metered design with onboard LCD display for real-time monitoring
- Single-phase operation with 230V AC input, 208V AC output
- NEMA L6-30P (2P3W) input plug configuration
- Rack-mountable vertical design for standard 19-inch enclosures
- Network management via HTTP(s), SSH, SNMP, and other protocols
- SecureLock receptacles prevent accidental power cord disconnection
- Branch circuit and overload protection for equipment safety
- 2-year limited warranty with RoHS environmental compliance
Specifications
| Specifications | |
|---|---|
| Manufacturer | Legrand Group |
| Manufacturer Part Number | PX3-1862-C5 |
| Brand Name | Raritan |
| Product Series | PX3 |
| Product Model | PX3-1862-C5 |
| Product Name | PX3-1862-C5 42-Outlets PDU |
| Product Type | PDU |
| Technical Information | |
| PDU Type | Metered |
| Phase | Single Phase |
| Plug/Connector Type | NEMA L6-30P (2P3W) |
| Receptacle Type | IEC 60320 C13,IEC 60320 C19 |
| Receptacle Detail | 36 x IEC 60320 C13,6 x IEC 60320 C19 |
| Protection Type | Branch Circuit,Overload Protection |
| Locking Receptacles | SecureLock |
| Features | LCD Display,Onboard Display |
| Load Capacity (VA) | 5 kW |
| Power Description | |
| Input Voltage | 230 V AC |
| Input Voltage Range | 200 V AC - 240 V AC |
| Output Voltage | 208 V AC |
| Output Voltage Range | 200 V AC - 240 V AC |
| Power Rating (VA) | 5.80 kVA |
| Input Current | 30 A |
| Input Frequency | 60 Hz |
| Management | |
| Management | HTTP(s) SSH Telnet RS-232 (série) Power IQ SNMP version v2/v3 SMTP JSON-RPC Modbus sur TCP |
| Remote Outlet Switching | No |
| Interfaces/Ports | |
| Network (RJ-45) | Yes |
| Physical Characteristics | |
| Color Family | Black |
| Product Color | Black Powder Coat |
| Mount Type | Rack-mountable |
| Cord Length | 9.8 ft (3 m) |
| Height | 70.10" (1780.54 mm) |
| Width | 2.10" (53.34 mm) |
| Depth | 2.20" (55.88 mm) |
| Weight (Approximate) | 13.89 lb (6300 g) |
| Environmental Conditions | |
| Maximum Operating Temperature | 140°F (60°C) |
| Maximum Operating Humidity | 85% |
| Miscellaneous | |
| Environmental Compliance | Restriction of Hazardous Substances (RoHS) |
| Warranty | |
| Limited Warranty | 2 Year |
FAQ
What is the total power capacity of this PDU?
The Raritan PX3-1862-C5 has a power rating of 5.80 kVA with a load capacity of 5 kW. This capacity is delivered through a 30-amp input circuit at 230V AC, making it suitable for powering multiple servers and network devices in a standard rack configuration.
How many outlets does this PDU have and what types are they?
This PDU provides 42 total outlets: 36 IEC 60320 C13 receptacles and 6 IEC 60320 C19 receptacles. The C13 outlets are standard for most server and network equipment, while the C19 outlets support higher-power devices that require more robust connections.
What input plug type does this PDU use?
The PDU features a NEMA L6-30P (2P3W) input plug, which is a locking 30-amp connector commonly used in commercial and data center environments for 208-240V AC circuits. This plug type provides a secure connection to the power source.
Can this PDU be monitored remotely?
Yes, the PDU includes network connectivity via an RJ-45 port and supports multiple management protocols including HTTP(s), SSH, Telnet, SNMP version v2/v3, SMTP, JSON-RPC, and Modbus over TCP. This allows integration with data center infrastructure management (DCIM) systems like Power IQ for remote monitoring and alerting.
Is this PDU rack-mountable and what are its dimensions?
Yes, this is a vertical rack-mountable PDU designed for standard 19-inch server racks. Its dimensions are 70.10 inches in height, 2.10 inches in width, and 2.20 inches in depth, allowing it to mount neatly alongside equipment without consuming valuable rack space.
What protection features does this PDU include?
The PDU incorporates branch circuit protection and overload protection to safeguard connected equipment. Additionally, it features SecureLock receptacles that provide a positive locking mechanism for power cords, preventing accidental disconnection in environments with vibration or movement.
What power capacity is listed for this UPS?
The listed power specification is 5 kW, which helps position the unit for the right load level and installation role.
How many outlets are available?
The product includes No, which helps buyers understand how many connected devices it can support in its intended deployment.