Shipping included*
Exclusions
Additional shipping fees may apply in rare circumstances for deliveries outside standard service areas. In most cases, this only potentially affects shipments to the Northwest Territories and Yukon, as well as certain heavy or oversized items.
Raritan PX3-3211 2-Outlet PDU - IEC C20 Input - 2x C19 Outlets - 120/230V AC - 16A - 1U Rack - Network Managed
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This PDU operates with an input current of 16A, handling dual voltage ranges from 120V to 230V AC. It provides two IEC C19 outlets, each compatible with standard server and networking equipment power cords. The built-in RJ-45 network port enables connectivity for advanced management protocols.
Management is comprehensive, supporting HTTP(s), SSH, Telnet, RS-232 serial, SNMP versions 2 and 3, SMTP, and JSON-RPC. This allows integration with existing network management systems and real-time monitoring through platforms like Power IQ.
This section brings together practical product details such as Plug/Connector Type, Plug/Connector Detail, Receptacle Type, Input Voltage, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
A strong technical summary explains how the product's interfaces, hardware profile, and operating characteristics work together in real deployment. Buyers often need this context to confirm compatibility with existing devices, expected performance in daily use, and whether installation will be straightforward for IT staff or end users.
Key Product Advantages
The PX3-3211 offers precise power distribution with dual voltage support, reducing the need for multiple PDUs in mixed-voltage environments. Its compact 1U design maximizes rack space efficiency, while the network management features provide granular control and monitoring.
These strengths make the product easier to deploy and manage in real environments, especially where reliability, usability, and day-to-day operational continuity matter. Notable benefits include Advanced Management, Dual Voltage Flexibility.
Advanced Management
Supports multiple protocols including SNMP v2/v3 and HTTP(s) for seamless integration into IT infrastructure management tools.
- Remote power monitoring
- Real-time alerts
- Integration with Power IQ
Dual Voltage Flexibility
Accepts both 120V and 230V AC input, making it suitable for global deployments and varied power infrastructures.
Deployment / Use Cases
Ideal for data centers, server rooms, and network closets where space-efficient power distribution is critical. The dual voltage capability supports environments with mixed power standards, such as international offices or colocation facilities.
Common applications include powering rack-mounted servers, switches, and storage arrays. The network management features make it suitable for environments requiring remote power cycling, energy usage tracking, and integration with DCIM solutions.
This section brings together practical product details such as Plug/Connector Type, Plug/Connector Detail, Receptacle Type, Input Voltage, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
Data Center Racks
Provides reliable power to critical equipment in high-density server racks, with management for uptime and efficiency.
Network Infrastructure
Powers networking gear like switches and routers, with remote management for troubleshooting and maintenance.
Physical Profile
The PDU has a slim 1U rack height, measuring 1.73 inches (44 mm) tall, 17.32 inches (440 mm) wide, and 7.20 inches (183 mm) deep. This compact form factor fits standard 19-inch racks without consuming excessive vertical space, leaving room for additional equipment.
The physical profile is practical for deployment planning because the dimensions and weight are clearly defined: 1U, 17.32" (440 mm), 7.20" (183 mm). This helps confirm rack, shelf, desk, or cabinet fit before installation.
- Width
- 17.32" (440 mm)
- Depth
- 7.20" (183 mm)
- Height
- 1U
Highlights
- Dual voltage input and output (120V/230V AC)
- 2 x IEC C19 outlets for high-power equipment
- 16A input current rating
- 1U rack height for space-efficient installation
- Network management via RJ-45 port
- Supports HTTP(s), SSH, Telnet, SNMP v2/v3
- Integration with Power IQ for monitoring
- RoHS compliant and environmentally friendly
Specifications
| Specifications | |
|---|---|
| Manufacturer | Legrand Group |
| Manufacturer Part Number | PX3-3211 |
| Brand Name | Raritan |
| Product Series | PX |
| Product Model | PX3-3211 |
| Product Name | PX3-3211 2-Outlet PDU |
| Product Type | PDU |
| Technical Information | |
| Plug/Connector Type | IEC 60320 C20 |
| Plug/Connector Detail | 2 x IEC 60320 C20 |
| Receptacle Type | IEC 60320 C19 |
| Receptacle Detail | 2 x IEC 60320 C19 |
| Power Description | |
| Input Voltage | 120 V AC,230 V AC |
| Input Voltage Range | 120 V AC - 230 V AC |
| Output Voltage | 230 V AC,120 V AC |
| Input Current | 16 A |
| Management | |
| Management | HTTP(s) SSH Telnet RS-232 (Serial) Power IQ SNMP version v2/v3 SMTP JSON-RPC |
| Interfaces/Ports | |
| Network (RJ-45) | Yes |
| Physical Characteristics | |
| Rack Height | 1U |
| Height | 1.73" (44 mm) |
| Width | 17.32" (440 mm) |
| Depth | 7.20" (183 mm) |
| Miscellaneous | |
| Country of Origin | Taiwan |
| Environmentally Friendly | Yes |
| Environmental Compliance | Restriction of Hazardous Substances (RoHS) |
User Manual
FAQ
What input voltages does the Raritan PX3-3211 PDU support?
The PDU supports dual input voltages of 120V AC and 230V AC, with an input voltage range from 120V to 230V AC. This flexibility allows it to work with common power standards in North America and internationally, accommodating varied electrical infrastructures without requiring additional transformers or adapters.
How many outlets does this PDU have and what type are they?
It features two IEC C19 outlets. These are standard connectors used for high-power devices like servers, network switches, and storage arrays. The outlets deliver the input voltage directly, supporting both 120V and 230V AC output as configured.
What management capabilities are included with this PDU?
The PDU includes comprehensive network management via an RJ-45 port, supporting protocols such as HTTP(s), SSH, Telnet, RS-232 serial, SNMP versions 2 and 3, SMTP, and JSON-RPC. This enables remote monitoring, power control, and integration with data center infrastructure management (DCIM) tools like Power IQ for real-time insights and alerts.
What are the physical dimensions and rack compatibility?
It has a compact 1U rack height, measuring 1.73 inches (44 mm) in height, 17.32 inches (440 mm) in width, and 7.20 inches (183 mm) in depth. This design fits standard 19-inch server racks, making it suitable for space-constrained environments like data centers or network closets without sacrificing rack real estate.
What is the input current rating of the PX3-3211?
The input current rating is 16A. This specifies the maximum current the PDU can draw from the power source, ensuring it can handle the load from connected equipment safely and efficiently within its dual voltage operating range.
Is this PDU environmentally compliant?
Yes, it is environmentally friendly and complies with the Restriction of Hazardous Substances (RoHS) directive. This means it is manufactured without certain hazardous materials, aligning with global environmental standards for electronic equipment and supporting sustainable IT practices.
What power capacity is listed for this UPS?
Power specifications help show where the unit fits best, including the type of load level, electrical environment, and backup role it is intended to support. These are usually the most decision-critical facts in a UPS or power-protection comparison.
What voltage details are listed?
The listed power specification is 120 V AC,230 V AC, which helps position the unit for the right load level and installation role.