Raritan PX3-5665U-C5 Monitored Rack PDU - 8. 60 kVA - 30 Outlets - 24x C13 - 6x C19 - 230V AC - NEMA L15-30P - 0U Vertical Mount
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This section brings together practical product details such as PDU Type, Phase, Plug/Connector Type, Input Voltage, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
A strong technical summary explains how the product's interfaces, hardware profile, and operating characteristics work together in real deployment. Buyers often need this context to confirm compatibility with existing devices, expected performance in daily use, and whether installation will be straightforward for IT staff or end users.
Electrical Specifications
This three-phase PDU accepts 230V AC input with an operating range of 208-240V AC and delivers 208V AC output across the same range. The 8.60 kVA power rating and 30A input current support high-density equipment deployments while maintaining electrical safety through overcurrent, overload, and double-pole protection mechanisms.
Network Management
Comprehensive remote management is enabled through multiple protocols including HTTP(s), SSH, Telnet, SNMP v2/v3, Modbus over TCP, and JSON-RPC. The integrated RJ-45 network interface supports Power IQ integration and allows for remote outlet switching, giving administrators control over individual outlet power states from any network location.
Key Product Advantages
This monitored PDU delivers critical visibility and control for modern data center power infrastructure. The ability to monitor voltage and current at the outlet level helps prevent circuit overloads before they cause downtime, while remote outlet switching enables efficient power cycling of equipment without physical access to the rack.
Outlet-Level Monitoring
Track power consumption for individual outlets to identify underutilized capacity and optimize rack power distribution. This granular visibility supports right-sizing of power infrastructure and helps extend the lifecycle of existing data center power systems.
- Prevents circuit overloads
- Identifies energy waste
- Supports capacity planning
Multi-Protocol Management
Compatible with existing network management systems through industry-standard protocols. The broad protocol support ensures integration with data center infrastructure management (DCIM) platforms and custom monitoring solutions without requiring proprietary software.
- SNMP v2/v3 compatible
- Modbus over TCP ready
- JSON-RPC API available
Deployment / Use Cases
The PX3-5665U-C5 is engineered for vertical mounting in standard 19-inch server racks, making it ideal for data centers, colocation facilities, and enterprise server rooms where space optimization is critical. The 0U form factor preserves valuable rack space for active equipment while providing comprehensive power distribution and monitoring.
This PDU supports mixed equipment environments through its combination of C13 and C19 outlets. The C13 outlets accommodate standard server and networking equipment power cords, while the higher-capacity C19 outlets support power-hungry devices such as blade chassis, high-performance servers, and storage arrays that require increased current delivery.
High-Density Server Racks
Deploy in racks containing multiple servers, switches, and storage systems where outlet-level power monitoring helps prevent circuit overloads and enables efficient capacity management.
Remote Data Center Management
Utilize the remote management capabilities to monitor and control power distribution from network operations centers, reducing the need for physical access to equipment racks in distributed or unmanned facilities.
Physical Profile
Designed for vertical mounting on rack posts, this 0U PDU measures 70.10 inches in height with a slim 2.10-inch width and 2.60-inch depth profile. The vertical orientation maximizes outlet accessibility while minimizing the footprint within the rack enclosure. The unit is constructed with RoHS-compliant materials and carries a 2-year limited warranty for reliable operation in data center environments.
The physical profile is practical for deployment planning because the dimensions and weight are clearly defined: 0U, 2.10" (53.34 mm), 2.60" (66.04 mm). This helps confirm rack, shelf, desk, or cabinet fit before installation.
- Width
- 2.10" (53.34 mm)
- Depth
- 2.60" (66.04 mm)
- Height
- 0U
Highlights
- 8.60 kVA three-phase power capacity for high-density rack deployments
- 30 total outlets with 24 IEC C13 and 6 IEC C19 receptacle configuration
- Monitored design provides outlet-level power measurement and remote management
- Vertical 0U rack mounting preserves space for active equipment
- NEMA L15-30P input plug for 230V AC three-phase power connection
- Remote outlet switching enables power cycling without physical rack access
- Multiple management protocols: HTTP(s), SSH, SNMP, Modbus over TCP, JSON-RPC
- RoHS compliant construction with 2-year limited warranty
Specifications
| Specifications | |
|---|---|
| Manufacturer | Legrand Group |
| Manufacturer Part Number | PX3-5665U-C5 |
| Brand Name | Raritan |
| Product Line | Rack |
| Product Series | PX3 |
| Product Model | PX3-5665U-C5 |
| Product Name | Rack PX3-5665U-C5 30-Outlets PDU |
| Product Type | PDU |
| Technical Information | |
| PDU Type | Monitored |
| Phase | Three Phase |
| Plug/Connector Type | NEMA L15-30P (3P4W) |
| Receptacle Type | IEC 60320 C13,IEC 60320 C19 |
| Receptacle Detail | 24 x IEC 60320 C13,6 x IEC 60320 C19 |
| Protection Type | Overcurrent Protection,Double Pole,Overload Protection |
| Power Description | |
| Input Voltage | 230 V AC |
| Input Voltage Range | 208 V AC - 240 V AC |
| Output Voltage | 208 V AC |
| Output Voltage Range | 208 V AC - 240 V AC |
| Power Rating (VA) | 8.60 kVA |
| Input Current | 30 A |
| Management | |
| Management | Protocols: HTTP(s) SSH Telnet; RS-232 (Serial) Power IQ SNMP version v2/v3 SMTP JSON-RPC Modbus over TCP |
| Remote Outlet Switching | Yes |
| Interfaces/Ports | |
| Network (RJ-45) | Yes |
| Physical Characteristics | |
| Mounting Orientation | Vertical |
| Mount Type | Rack-mountable |
| Rack Height | 0U |
| Height | 70.10" (1780.54 mm) |
| Width | 2.10" (53.34 mm) |
| Depth | 2.60" (66.04 mm) |
| Miscellaneous | |
| Environmentally Friendly | Yes |
| Environmental Compliance | Restriction of Hazardous Substances (RoHS) |
| Warranty | |
| Limited Warranty | 2 Year |
User Manual
FAQ
What is the power capacity of this Raritan PDU?
The Raritan PX3-5665U-C5 delivers 8.60 kVA of three-phase power capacity with a 30A input current rating. This capacity supports multiple servers, networking equipment, and storage devices in a single rack while maintaining headroom for future expansion and preventing circuit overloads in data center environments.
How many outlets does this PDU have and what types are they?
This PDU features 30 total outlets configured as 24 IEC 60320 C13 receptacles and 6 IEC 60320 C19 receptacles. The C13 outlets accommodate standard server and networking equipment, while the C19 outlets support higher-power devices such as blade chassis and high-performance servers that require increased current delivery.
What input plug type does this PDU use?
The PDU uses a NEMA L15-30P (3P4W) plug for three-phase power connection. This plug type is designed for 230V AC input voltage with a 30A rating, making it suitable for data center power distribution systems that provide three-phase power to server racks.
How is this PDU mounted in a server rack?
This PDU is designed for vertical 0U mounting on rack posts. The vertical orientation provides easy access to all outlets while consuming zero rack units of vertical space, preserving valuable rack real estate for servers, switches, and other active equipment in high-density deployments.
What management capabilities does this monitored PDU offer?
The PDU offers comprehensive remote management through multiple protocols including HTTP(s), SSH, Telnet, SNMP v2/v3, Modbus over TCP, and JSON-RPC. These capabilities enable outlet-level power monitoring, remote outlet switching, and integration with data center infrastructure management (DCIM) platforms for centralized power management.
What protection features are included with this PDU?
The PDU incorporates overcurrent protection, overload protection, and double-pole protection mechanisms to safeguard connected equipment. These electrical protections help prevent damage from power anomalies while maintaining reliable operation in demanding data center environments where equipment uptime is critical.
What power capacity is listed for this UPS?
The listed power specification is 8.60 kVA, which helps position the unit for the right load level and installation role.
How many outlets are available?
The product includes Yes, which helps buyers understand how many connected devices it can support in its intended deployment.