Technical Overview
This PDU accepts three-phase power input at 415V AC with a working range of 360-415V AC, delivering output at 208V AC with a range of 208-240V AC. The 30A input current supports the full 17.3 kVA capacity, making it suitable for powering multiple high-draw devices simultaneously.
The metered-by-outlet functionality provides individual outlet power monitoring, enabling precise tracking of energy consumption per connected device. Protection features include branch circuit and overload protection to safeguard connected equipment from power anomalies.
This section brings together practical product details such as PDU Type, Phase, Plug/Connector Type, Input Voltage, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
A strong technical summary explains how the product's interfaces, hardware profile, and operating characteristics work together in real deployment. Buyers often need this context to confirm compatibility with existing devices, expected performance in daily use, and whether installation will be straightforward for IT staff or end users.
Key Product Advantages
The combination of switched outlets with individual metering provides unprecedented control and visibility into power usage at the device level. Remote outlet switching enables power cycling of individual devices without physical access to the equipment, reducing downtime during troubleshooting and maintenance operations.
These strengths make the product easier to deploy and manage in real environments, especially where reliability, usability, and day-to-day operational continuity matter. Notable benefits include Granular Power Monitoring, Comprehensive Management.
Granular Power Monitoring
Metered-by-outlet capability allows monitoring of individual outlet power consumption, enabling detailed energy usage analysis and capacity planning.
- Per-outlet power measurement
- Real-time consumption data
- Capacity optimization insights
Comprehensive Management
Multiple management protocols provide flexible integration with existing infrastructure management systems.
- HTTP(s), SSH, Telnet access
- SNMP v2/v3 support
- Modbus over TCP integration
Deployment / Use Cases
This PDU is designed for environments where precise power monitoring and remote management are essential. The three-phase power input makes it particularly suitable for larger data center installations where three-phase power distribution is standard.
The 24 C19 outlets support equipment with higher power requirements, typically found in server and networking environments. The 1U form factor maximizes rack space efficiency while providing substantial power distribution capacity.
This section brings together practical product details such as PDU Type, Phase, Plug/Connector Type, Input Voltage, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
Data Center Power Distribution
Ideal for server racks requiring multiple C19 connections with individual power monitoring and control capabilities.
Network Equipment Power Management
Suitable for networking closets with high-density switch and router installations needing remote power management.
Physical Profile
With dimensions of 70.10" height, 1.80" width, and 3.90" depth, this PDU is designed for vertical mounting in standard 19-inch racks. The 1U rack height minimizes space consumption while the 9.8-foot power cord provides flexibility in rack placement relative to power sources.
The black powder coat finish resists scratches and corrosion, maintaining appearance in demanding environments. At approximately 10.90 kg, the unit has substantial construction while remaining manageable for installation in standard rack configurations.
- Width
- 1.80" (45.72 mm)
- Depth
- 3.90" (99.06 mm)
- Height
- 1U
- Weight
- 10.90 kg
- Length
- 9.8 ft
Highlights
- 17.3 kVA power capacity for high-density equipment
- 24 IEC C19 outlets with SecureLock locking mechanism
- Metered-by-outlet monitoring for individual device power tracking
- Three-phase 415V AC input with 208V AC output
- 1U rack-mountable design with black powder coat finish
- Remote outlet switching via network management
- Multiple management protocols: HTTP(s), SSH, SNMP, Modbus
- Onboard LCD display for local power monitoring
- Branch circuit and overload protection
- 2-year limited warranty
Specifications
| Specifications | |
|---|---|
| Manufacturer | Legrand Group |
| Manufacturer Part Number | PX3-5690U-N1V2 |
| Brand Name | Raritan |
| Product Series | PX3 |
| Product Model | PX3-5690U-N1V2 |
| Product Name | PX3-5690U-N1V2 12-Outlets PDU |
| Product Type | PDU |
| Technical Information | |
| PDU Type | Switched with Metered-by-Outlet |
| Phase | Three Phase |
| Plug/Connector Type | NEMA L22-30P (4P5W) |
| Receptacle Type | IEC 60320 C19 |
| Receptacle Detail | 24 x IEC 60320 C19 |
| Protection Type | Branch Circuit,Overload Protection |
| Locking Receptacles | SecureLock |
| Features | LCD Display,Onboard Display |
| Load Capacity (VA) | 17.30 W |
| Power Description | |
| Input Voltage | 415 V AC |
| Input Voltage Range | 360 V AC - 415 V AC |
| Output Voltage | 208 V AC |
| Output Voltage Range | 208 V AC - 240 V AC |
| Power Rating (VA) | 17.30 kVA |
| Input Current | 30 A |
| Input Frequency | 60 Hz |
| Management | |
| Management | HTTP(s) SSH Telnet RS-232 (Serial) Power IQ SNMP version v2/v3 SMTP JSON-RPC Modbus over TCP |
| Remote Outlet Switching | Yes |
| Interfaces/Ports | |
| Network (RJ-45) | Yes |
| Physical Characteristics | |
| Product Color | Black Powder Coat |
| Mount Type | Rack-mountable,Button Mount |
| Rack Height | 1U |
| Cord Length | 9.8 ft |
| Height | 70.10" (1780.54 mm) |
| Width | 1.80" (45.72 mm) |
| Depth | 3.90" (99.06 mm) |
| Weight (Approximate) | 10.90 kg |
| Environmental Conditions | |
| Maximum Operating Temperature | 140°F (60°C) |
| Maximum Operating Humidity | 85% |
| Miscellaneous | |
| Environmental Compliance | Restriction of Hazardous Substances (RoHS) |
| Warranty | |
| Limited Warranty | 2 Year |
User Manual
FAQ
What is the power capacity of this PDU?
The Raritan PX3-5690U-N1V2 has a power rating of 17.30 kVA, which represents its maximum apparent power capacity. This capacity is delivered through a 30A input at 415V AC three-phase power, making it suitable for powering multiple high-draw servers or networking devices simultaneously in data center environments.
How many outlets does this PDU have and what type are they?
This PDU features 24 IEC 60320 C19 outlets. C19 connectors are designed for higher power equipment typically found in server and networking environments. The outlets include SecureLock locking mechanisms to prevent accidental disconnections, ensuring reliable power delivery to critical equipment.
What input voltage does this PDU require?
The PDU requires three-phase 415V AC input power. It accepts a voltage range of 360-415V AC, providing flexibility in environments with minor voltage fluctuations. The three-phase design is standard for larger data center power distribution systems where balanced power loading across phases is important.
What management capabilities does this switched PDU offer?
This PDU offers comprehensive management through multiple protocols including HTTP(s), SSH, Telnet, SNMP v2/v3, and Modbus over TCP. The metered-by-outlet functionality provides individual outlet power monitoring, while remote outlet switching allows power cycling of specific devices without physical access. Integration with Power IQ and support for JSON-RPC and SMTP alerts enhance monitoring capabilities.
What rack space does this PDU occupy?
The PDU occupies 1U of vertical rack space and is designed for mounting in standard 19-inch racks. With dimensions of 70.10" height, 1.80" width, and 3.90" depth, it provides substantial power distribution capacity while minimizing space consumption. The vertical orientation is typical for PDU installations in server racks.
What protection features does this PDU include?
The PDU includes branch circuit protection and overload protection to safeguard connected equipment. These protection mechanisms help prevent damage from power anomalies and ensure reliable operation. The design meets environmental compliance standards including RoHS (Restriction of Hazardous Substances) and operates within a temperature range up to 140°F (60°C) and humidity up to 85%.
What power capacity is listed for this UPS?
The listed power specification is 17.30 W, which helps position the unit for the right load level and installation role.
How many outlets are available?
The product includes Yes, which helps buyers understand how many connected devices it can support in its intended deployment.