Raritan PX3-5704U-O1V2 Switched Metered-by-Outlet PDU - 36 x IEC C13 Outlets - 17. 30 kVA - 415 V AC Input - 208 V AC Output - Rack-Mountable
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This PDU operates with a 415 V AC input voltage, accepting a range from 360 V AC to 415 V AC, and delivers 208 V AC output, adjustable from 208 V AC to 240 V AC. The 30 A input current and 60 Hz frequency ensure compatibility with standard three-phase power infrastructures. Protection features include branch circuit and overload protection, while SecureLock locking receptacles prevent accidental disconnections.
The metered-by-outlet functionality provides individual outlet power monitoring, allowing administrators to track consumption at the device level. This granular visibility supports capacity planning, power budgeting, and identifying underutilized or overloaded circuits.
This section brings together practical product details such as PDU Type, Phase, Plug/Connector Type, Input Voltage, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
A strong technical summary explains how the product's interfaces, hardware profile, and operating characteristics work together in real deployment. Buyers often need this context to confirm compatibility with existing devices, expected performance in daily use, and whether installation will be straightforward for IT staff or end users.
Key Product Advantages
The PX3-5704U-O1V2 combines high-density power distribution with intelligent management tools, making it an ideal solution for modern data centers requiring both capacity and control.
Individual Outlet Monitoring
Metered-by-outlet capability provides real-time power consumption data for each of the 36 IEC C13 outlets, enabling precise chargeback, troubleshooting, and optimization.
- Per-outlet power metering
- Real-time consumption data
- Supports chargeback models
Comprehensive Remote Management
Multiple management protocols including HTTP(s), SSH, SNMP, and Modbus over TCP allow integration with existing data center infrastructure management (DCIM) systems and remote administration tools.
- Multiple protocol support
- DCIM integration
- Remote configuration
High-Density Power Distribution
With 36 IEC C13 outlets in a compact rack-mountable design, this PDU maximizes power distribution within limited rack space while maintaining proper airflow and accessibility.
- 36 outlet capacity
- Rack-optimized design
- Space-efficient layout
Deployment / Use Cases
This switched metered-by-outlet PDU is designed for deployment in data centers, server rooms, and network closets where reliable power distribution with monitoring capabilities is essential. The 415 V AC input and 208 V AC output configuration makes it suitable for three-phase power environments commonly found in enterprise and colocation facilities.
Ideal applications include server racks hosting virtualization clusters, storage arrays, networking equipment, or any IT infrastructure requiring individual outlet control and monitoring. The remote switching capability allows administrators to power cycle specific devices without physical access to the data center, reducing downtime and operational costs.
Data Center Power Management
Deploy in server racks to distribute power to multiple devices while monitoring consumption at the outlet level for capacity planning and efficiency reporting.
Remote Site Management
Utilize network management protocols to monitor and control power distribution at unmanned or geographically dispersed locations from a central management console.
Physical Profile
The PDU features a rack-mountable design with dimensions of 70.10 inches in height, 2.10 inches in width, and 2.60 inches in depth, optimized for standard 19-inch server racks. The black powder coat finish provides durability and a professional appearance that blends with data center equipment. A 9.8-foot power cord offers flexible placement options within the rack environment.
- Width
- 2.10" (53.34 mm)
- Depth
- 2.60" (66.04 mm)
- Height
- 70.10" (1780.54 mm)
- Weight
- 9.60 kg
- Length
- 9.8 ft
Highlights
- Switched metered-by-outlet PDU with individual outlet monitoring
- 36 IEC C13 outlets for high-density power distribution
- 17.30 kVA power rating with 415 V AC input and 208 V AC output
- Three-phase operation with 30 A input current at 60 Hz
- Remote outlet switching and comprehensive network management
- Rack-mountable design with black powder coat finish
- LCD display for local status monitoring
- SecureLock locking receptacles prevent accidental disconnections
- Branch circuit and overload protection
- 2-year limited warranty
Specifications
| Specifications | |
|---|---|
| Manufacturer | Legrand Group |
| Manufacturer Part Number | PX3-5704U-O1V2 |
| Brand Name | Raritan |
| Product Series | PX3 |
| Product Model | PX3-5704U-O1V2 |
| Product Name | PX3-5704U-O1V2 36-Outlets PDU |
| Product Type | PDU |
| Technical Information | |
| PDU Type | Switched with Metered-by-Outlet |
| Phase | Three Phase |
| Plug/Connector Type | NEMA L22-30P (4P5W) |
| Receptacle Type | IEC 60320 C13 |
| Receptacle Detail | 36 x IEC 60320 C13 |
| Protection Type | Branch Circuit,Overload Protection |
| Locking Receptacles | SecureLock |
| Features | LCD Display,Onboard Display |
| Load Capacity (VA) | 17.30 W |
| Power Description | |
| Input Voltage | 415 V AC |
| Input Voltage Range | 360 V AC - 415 V AC |
| Output Voltage | 208 V AC |
| Output Voltage Range | 208 V AC - 240 V AC |
| Power Rating (VA) | 17.30 kVA |
| Input Current | 30 A |
| Input Frequency | 60 Hz |
| Management | |
| Management | HTTP(s) SSH Telnet RS-232 (Serial) Power IQ SNMP version v2/v3 SMTP JSON-RPC Modbus over TCP |
| Remote Outlet Switching | Yes |
| Interfaces/Ports | |
| Network (RJ-45) | Yes |
| Physical Characteristics | |
| Product Color | Black Powder Coat |
| Mount Type | Rack-mountable |
| Cord Length | 9.8 ft |
| Height | 70.10" (1780.54 mm) |
| Width | 2.10" (53.34 mm) |
| Depth | 2.60" (66.04 mm) |
| Weight (Approximate) | 9.60 kg |
| Environmental Conditions | |
| Maximum Operating Temperature | 140°F (60°C) |
| Maximum Operating Humidity | 85% |
| Miscellaneous | |
| Environmental Compliance | Restriction of Hazardous Substances (RoHS) |
| Warranty | |
| Limited Warranty | 2 Year |
User Manual
FAQ
What type of PDU is the Raritan PX3-5704U-O1V2?
The Raritan PX3-5704U-O1V2 is a switched metered-by-outlet power distribution unit. This means it provides individual outlet-level power monitoring (metered) and remote control capabilities (switched) for each of its 36 IEC C13 outlets, allowing precise management of connected devices.
What is the power capacity of this PDU?
This PDU has a power rating of 17.30 kVA. It operates with a 415 V AC input voltage (range 360-415 V AC) and delivers 208 V AC output (range 208-240 V AC) with a 30 A input current at 60 Hz frequency, making it suitable for three-phase power environments.
How many outlets does this PDU have and what type are they?
The PDU features 36 IEC 60320 C13 outlets. These are standard connectors commonly used for servers, networking equipment, and other IT devices. The outlets include SecureLock locking mechanisms to prevent accidental disconnections.
What management capabilities does this PDU offer?
This PDU supports multiple management protocols including HTTP(s), SSH, Telnet, RS-232 serial, SNMP versions v2 and v3, SMTP, JSON-RPC, and Modbus over TCP. It also includes remote outlet switching, allowing administrators to control individual outlets remotely via network connections.
Is this PDU rack-mountable and what are its dimensions?
Yes, this PDU is designed for rack mounting. Its dimensions are 70.10 inches in height, 2.10 inches in width, and 2.60 inches in depth, making it compatible with standard 19-inch server racks. The unit weighs approximately 9.60 kg and features a black powder coat finish.
What type of power input connector does this PDU use?
The PDU uses a NEMA L22-30P (4P5W) plug/connector for power input. This is a locking connector type designed for three-phase power applications, providing a secure connection to the power source with proper grounding.
What power capacity is listed for this UPS?
The listed power specification is 17.30 W, which helps position the unit for the right load level and installation role.
How many outlets are available?
The product includes Yes, which helps buyers understand how many connected devices it can support in its intended deployment.