StarTech.com RKPW101920 10-Outlet Rack Mount Power Strip - 1U Horizontal 19" PDU - 125V/16A - NEMA 5-20P Input - 10x NEMA 5-15/20R Outlets
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This rack mount power strip handles 120V AC input with a maximum output of 125V AC at 16A current. The electrical specifications support 50-60Hz frequency ranges, making it compatible with standard North American power systems. The built-in 20A circuit breaker provides overload protection to safeguard connected equipment.
The PDU's 10 outlets use NEMA 5-15/20R configurations, accommodating both 15A and 20A plugs. This outlet flexibility allows for mixed device deployments without requiring adapters. The unit maintains stable power delivery across all outlets simultaneously when operating within its 16A maximum current rating.
Relevant factors for this section include Receptacles, Cord Length, Circuit Breaker, Input Voltage. When those points are considered together, they give buyers a clearer picture of how the product is equipped, how it fits into deployment, and what kind of day-to-day role it is meant to support.
Key Product Advantages
This StarTech.com PDU combines installation flexibility with robust power distribution capabilities. The 1U horizontal design maximizes rack space efficiency while providing ample outlet capacity for rack-mounted equipment. The metal construction ensures durability in high-density server environments.
Professional-Grade Construction
Built with steel and plastic materials for long-term reliability in data center conditions. The housing withstands vibration and maintains structural integrity in multi-rack installations.
- Steel-reinforced chassis
- Plastic outlet housings
- Front-mounted power switch
Comprehensive Safety Features
Includes a 20A circuit breaker that automatically trips during overload conditions, preventing damage to connected devices. The unit carries relevant safety certifications for commercial use.
- 20A circuit breaker
- UL listed
- RoHS 2 compliant
Deployment / Use Cases
This rack mount power strip serves as primary power distribution in standard 19" server racks and network cabinets. Its 1U horizontal format fits both 2-post and 4-post racks with minimum 4" depth requirements, making it versatile for various data center configurations.
Ideal applications include server rack power distribution, network switch power aggregation, and patch panel power support. The 10 outlets can power multiple servers, switches, routers, or other rack-mounted equipment simultaneously. IT professionals deploy this PDU in data centers, colocation facilities, and enterprise server rooms where reliable, organized power distribution is essential.
Data Center Power Distribution
Provides centralized power for server racks containing multiple blade servers, storage arrays, and networking equipment. The horizontal mounting conserves vertical rack space for additional equipment.
Network Cabinet Power Management
Organizes power for switches, routers, and other networking gear in telecommunications closets. The front-facing outlets and switch allow easy access without removing equipment from racks.
Physical Profile
The PDU measures 17.50" wide to fit standard 19" rack widths, with a 2" height that occupies exactly 1U of vertical rack space. The black finish blends with most rack equipment, while the horizontal orientation provides optimal outlet accessibility. Weighing approximately 2.70 lb, it installs easily without requiring additional support brackets in properly configured racks.
- Width
- 17.50" (444.50 mm)
- Height
- 1U
- Weight
- 2.70 lb (1224.70 g)
- Length
- 8 ft (2.44 m)
What's in the Box
The package includes all components needed for immediate installation and operation.
Highlights
- 10 NEMA 5-15/20R outlets for flexible device connections
- 1U horizontal mounting fits standard 19" server racks
- 125V/16A maximum output capacity
- 8ft NEMA 5-20P to IEC 60320 C19 power cord included
- Built-in 20A circuit breaker for overload protection
- Metal and plastic construction for durability
- Front-facing power switch for easy access
- Compatible with 2-post and 4-post rack systems
- Meets ANSI/EIA RS-310-D installation standards
- 2-year warranty with lifetime technical support
Specifications
| Specifications | |
|---|---|
| Manufacturer | StarTech.com |
| Manufacturer Part Number | RKPW101920 |
| Brand Name | StarTech.com |
| Product Name | 10-Outlets Power Strip |
| Packaged Quantity | 1 Each |
| Product Type | Power Strip |
| Technical Information | |
| Receptacles | 10 x AC Power |
| Cord Length | 8 ft (2.44 m) |
| Circuit Breaker | Yes |
| Power Description | |
| Input Voltage | 120 V AC |
| Maximum Output Voltage | 125 V AC |
| Maximum Input Current | 16 A |
| Minimum Frequency | 50 Hz |
| Maximum Frequency | 60 Hz |
| Physical Characteristics | |
| Color Family | Black |
| Product Color | Black |
| Product Material | Plastic,Steel |
| Form Factor | Rack-mountable |
| Rack Height | 1U |
| Mount Type | Horizontal |
| Height | 2" (50.80 mm) |
| Width | 17.50" (444.50 mm) |
| Weight (Approximate) | 2.70 lb (1224.70 g) |
| Miscellaneous | |
| Package Contents | 10-Outlets Power Strip 8 ft NEMA 5-20P to IEC 60320 C19 Power Cord Quick-Start Guide |
| Country of Origin | China |
| Environmentally Friendly | Yes |
| Environmental Certification | EU RoHS |
| Environmental Compliance | Restriction of Hazardous Substances (RoHS) 2,Registration, Evaluation, Authorization and Restriction of Chemicals (REACH),Waste Electrical and Electronic Equipment Directive (WEEE) |
| Warranty | |
| Limited Warranty | 2 Year |
User Manual
FAQ
What type of power input does this rack PDU require?
This power distribution unit uses a NEMA 5-20P input plug that connects to standard 120V AC outlets. The included 8ft power cord features a NEMA 5-20P connector on one end and an IEC 60320 C19 connector on the PDU end. It requires a 20A circuit for optimal operation, though it can function on 15A circuits while respecting the 16A maximum input current rating.
How many devices can I connect to this 10-outlet PDU?
You can connect up to 10 devices simultaneously using the NEMA 5-15/20R outlets. However, the total connected load must not exceed the 16A maximum input current. For devices with higher power requirements, you should calculate the cumulative amperage to ensure it stays within the 16A limit. The outlets support both 15A and 20A plugs without requiring adapters.
What rack types is this power strip compatible with?
This PDU is compatible with standard 19" server racks, including both 2-post and 4-post designs. It requires a minimum rack depth of 4" (10.2cm) for proper installation. The 1U horizontal mounting uses standard rack screw holes spaced according to ANSI/EIA RS-310-D specifications, ensuring compatibility with most commercial server racks and network cabinets.
Does this rack PDU include overload protection?
Yes, the unit features a built-in 20A circuit breaker that provides overload protection. If the total current draw exceeds safe levels, the circuit breaker will automatically trip to prevent damage to connected equipment. This protection mechanism helps safeguard servers, switches, and other critical infrastructure from electrical faults while maintaining compliance with safety standards.
What warranty and support comes with this StarTech.com PDU?
StarTech.com backs this rack mount power strip with a 2-year limited warranty covering manufacturing defects. Additionally, the product includes free lifetime 24/5 multi-lingual technical assistance. This support provides installation guidance, troubleshooting help, and product information during business hours, giving IT professionals reliable access to expert assistance when needed.
Can this PDU be used in international locations?
This power strip is designed for North American power systems with 120V AC input and 50-60Hz frequency ranges. While it carries EU RoHS environmental certifications, the electrical specifications are optimized for North American voltage standards. For use in other regions, you would need appropriate voltage conversion equipment and should verify local electrical code compliance before deployment.