Server Technology C3S36RL-GPJE2MT2 PRO3 x 36-Outlet PDU - Monitored - 415V AC Three Phase - 18 CX & 18 C13 Outlets - 0U Rack Mount
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This PRO3X PDU operates with 415V AC three-phase input at 30A current, delivering 17.30 kW of power capacity to support high-density server deployments. The unit features circuit protection to safeguard connected equipment from electrical anomalies while maintaining consistent power delivery.
Network connectivity through RJ-45 enables comprehensive remote management via multiple protocols including HTTP, HTTPS, SSHv2, and Telnet. Security is maintained through TLSv1.2 encryption, SNMP v2c and v3 support with GET, SET, and Traps functionality, plus enterprise authentication through TACACS+ and RADIUS systems.
This section brings together practical product details such as PDU Type, Phase, Plug/Connector Type, Input Voltage, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
A strong technical summary explains how the product's interfaces, hardware profile, and operating characteristics work together in real deployment. Buyers often need this context to confirm compatibility with existing devices, expected performance in daily use, and whether installation will be straightforward for IT staff or end users.
Key Product Advantages
The monitored capabilities of this PDU provide significant advantages for modern data center management. Remote monitoring of single- or three-phase voltage enables proactive maintenance and prevents downtime by identifying potential power issues before they affect critical systems.
Intelligent Load Distribution
Automatically balances electrical load across all three phases to prevent circuit overload and optimize power efficiency in high-density server environments.
- Prevents phase imbalance
- Maximizes power utilization
- Reduces thermal stress
Comprehensive Remote Management
Offers multiple management interfaces including web-based HTTP/HTTPS access, command-line SSHv2, and SNMP integration for seamless incorporation into existing monitoring systems.
- Web browser access
- Command-line control
- SNMP integration
Zero Rack Space Design
The 0U form factor mounts vertically in standard 19-inch racks without consuming valuable horizontal space, ideal for maximizing equipment density in constrained data centers.
- Vertical mounting
- No horizontal space used
- Standard 19-inch compatibility
Deployment / Use Cases
This 36-outlet PDU is engineered for data center environments requiring high-density power distribution with monitoring capabilities. The three-phase 415V AC input makes it suitable for enterprise server rooms, colocation facilities, and cloud infrastructure deployments where reliable power distribution is critical.
The combination of CX and C13 outlets supports mixed equipment environments, from servers and storage arrays to networking gear and peripheral devices. The 0U vertical mounting design is particularly valuable in fully populated racks where horizontal space is at a premium.
High-Density Server Racks
Ideal for fully populated server racks in data centers, providing power to 36 devices while maintaining load balance across all three phases for optimal electrical efficiency.
Remote Monitoring Environments
Perfect for facilities requiring off-site power management, with comprehensive protocol support for integration into existing network management systems and dashboards.
Physical Profile
Designed for vertical rack mounting, this PDU features a slim 2.20-inch width that fits neatly in standard 19-inch rack enclosures. The 70-inch height provides ample outlet spacing for proper cable management, while the 2.50-inch depth ensures compatibility with most rack configurations without protruding into equipment space.
The physical profile is practical for deployment planning because the dimensions and weight are clearly defined: 0U, 2.20" (55.88 mm), 2.50" (63.50 mm). This helps confirm rack, shelf, desk, or cabinet fit before installation.
- Width
- 2.20" (55.88 mm)
- Depth
- 2.50" (63.50 mm)
- Height
- 0U
Highlights
- 36 total outlets with 18 CX and 18 C13 receptacles for versatile equipment connectivity
- 415V AC three-phase input with 30A current capacity for high-power applications
- 17.30 kW power rating supports demanding server and storage deployments
- Monitored PDU with remote voltage monitoring capabilities
- 0U vertical rack mount design conserves valuable horizontal space
- Network management via RJ-45 with HTTP, HTTPS, SSHv2, and Telnet access
- Enterprise security with TLSv1.2, SNMP v2c/v3, and TACACS+/RADIUS authentication
- Circuit protection safeguards connected equipment from electrical anomalies
- IEC 60309 3P+N+G 6Hr 30A input connector for reliable three-phase connection
- Load balancing across all three phases prevents circuit overload
Specifications
| Specifications | |
|---|---|
| Manufacturer | Legrand Group |
| Manufacturer Part Number | C3S36RL-GPJE2MT2 |
| Brand Name | Server Technology |
| Product Line | PRO3X |
| Product Name | PRO3X 36-Outlet PDU |
| Product Type | PDU |
| Technical Information | |
| PDU Type | Monitored |
| Phase | Three Phase |
| Plug/Connector Type | IEC 60309 3P+N+G 6Hr 30A |
| Receptacle Type | CX,IEC 60320 C13 |
| Receptacle Detail | 18 x CX,18 x IEC 60320 C13 |
| Protection Type | Circuit Protection |
| Power Description | |
| Input Voltage | 415 V AC |
| Power Rating (Watt) | 17.30 kW |
| Input Current | 30 A |
| Management | |
| Management | HTTP HTTPS TLSv1.2 SSHv2 Telnet SNMP v2c SNMP v3 (GET, SET, Traps) IPv4 IPv6 LDAPv3 LDAPS TACACS+ RADIUS FTP SFTP |
| Interfaces/Ports | |
| Network (RJ-45) | Yes |
| Physical Characteristics | |
| Mount Type | Rack-mountable |
| Rack Height | 0U |
| Height | 70" (1778 mm) |
| Width | 2.20" (55.88 mm) |
| Depth | 2.50" (63.50 mm) |
FAQ
What is the input voltage and phase configuration for this PDU?
This Server Technology PRO3X PDU accepts 415V AC three-phase input through an IEC 60309 3P+N+G 6Hr 30A connector. The three-phase configuration provides balanced power distribution ideal for data center environments, with each phase carrying equal load to maximize electrical efficiency and prevent circuit overload in high-density server installations.
How many outlets does this PDU have and what types are they?
The PDU features 36 total outlets, consisting of 18 CX receptacles and 18 IEC 60320 C13 receptacles. This mixed configuration accommodates diverse equipment types commonly found in data centers, from servers and storage devices to networking equipment and peripherals, providing flexibility for various power cord requirements in rack-mounted environments.
What is the power rating and current capacity of this unit?
This PDU has a power rating of 17.30 kW with an input current capacity of 30A. This substantial power handling capability supports high-density server deployments where multiple devices require consistent, reliable power distribution without voltage drops or circuit overloads that could affect equipment performance.
How is this PDU mounted in a rack and what space does it require?
The PDU uses a 0U vertical mounting design that installs along the side or rear of standard 19-inch racks without consuming horizontal rack space. With dimensions of 70 inches high, 2.20 inches wide, and 2.50 inches deep, it fits neatly in most rack enclosures while providing ample outlet spacing for proper cable management in densely populated server environments.
What remote management capabilities does this monitored PDU offer?
This PDU provides comprehensive remote management through network connectivity via RJ-45. Management protocols include HTTP and HTTPS for web-based access, SSHv2 for secure command-line control, Telnet for legacy system compatibility, and SNMP v2c/v3 for integration with network monitoring systems. Security features include TLSv1.2 encryption and enterprise authentication through TACACS+ and RADIUS.
What type of protection does this PDU provide for connected equipment?
The PDU includes circuit protection to safeguard connected servers and networking equipment from electrical anomalies. This protection works in conjunction with the unit's load balancing capabilities, which automatically distribute electrical load evenly across all three phases to prevent circuit overloads and maintain stable power delivery to critical infrastructure in data center environments.
What power capacity is listed for this UPS?
The listed power specification is 17.30 kW, which helps position the unit for the right load level and installation role.
What voltage details are listed?
The listed power specification is 415 V AC, which helps position the unit for the right load level and installation role.