Sidebar Sidebar Sidebar
sale
Sold out

Shipping included*

Server Technology C3S36RL-GPJE2MT2 PRO3 x 36-Outlet PDU - Monitored - 415V AC Three Phase - 18 CX & 18 C13 Outlets - 0U Rack Mount

SKU: C3S36RL-GPJE2MT2
(No reviews) Write a Review
MSRP: $3,179.87
$3,179.87
$2,986.99
Save: $192.88 (6.07%)
Warranty Information: Covered by Manufacturer
Condition: New
Width: 5.59 (cm)
Height: 177.80 (cm)
Depth: 6.35 (cm)

Ask for ETA! 🗨️

Logo cards
B2B Pricing

Business volume discounts

IT Experts

Technical guidance

IT Configuration

Preparation & staging

Canada Stock

QC · ON · AB · BC

Product Features

Description

Product Overview

The Server Technology PRO3X 36-Outlet PDU delivers reliable three-phase power distribution for demanding data center and server room environments. This monitored PDU model C3S36RL-GPJE2MT2 provides intelligent power management with remote monitoring capabilities, allowing IT administrators to maintain optimal power delivery across critical infrastructure.

Designed for high-density rack installations, this unit accepts 415V AC three-phase input through an IEC 60309 3P+N+G 6Hr 30A connector and distributes power through 36 strategically arranged outlets. The combination of 18 CX and 18 IEC 60320 C13 receptacles accommodates diverse equipment configurations while maintaining proper load balancing across all three phases.

This section brings together practical product details such as PDU Type, Phase, Plug/Connector Type, Input Voltage, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.

Power
17.30 kW
Power Capacity
415 V AC0U
Power Capacity
Input Voltage415 V AC
Power Rating17.30 kW
Input Current30 A
Outlet Configuration
Total Outlets36
CX Outlets18
C13 Outlets18
Physical Installation
Rack Height0U
Mount TypeRack-mountable
Dimensions70" H × 2.20" W × 2.50" D
Management Protocols
Network ProtocolsHTTP, HTTPS, SSHv2, Telnet
Security StandardsTLSv1.2, SNMP v2c/v3, LDAPv3, LDAPS
AuthenticationTACACS+, RADIUS

Technical Overview

This PRO3X PDU operates with 415V AC three-phase input at 30A current, delivering 17.30 kW of power capacity to support high-density server deployments. The unit features circuit protection to safeguard connected equipment from electrical anomalies while maintaining consistent power delivery.

Network connectivity through RJ-45 enables comprehensive remote management via multiple protocols including HTTP, HTTPS, SSHv2, and Telnet. Security is maintained through TLSv1.2 encryption, SNMP v2c and v3 support with GET, SET, and Traps functionality, plus enterprise authentication through TACACS+ and RADIUS systems.

This section brings together practical product details such as PDU Type, Phase, Plug/Connector Type, Input Voltage, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.

A strong technical summary explains how the product's interfaces, hardware profile, and operating characteristics work together in real deployment. Buyers often need this context to confirm compatibility with existing devices, expected performance in daily use, and whether installation will be straightforward for IT staff or end users.

Input Voltage415 V AC
Power Rating17.30 kW
Input Current30 A
Three Phase PowerCircuit ProtectionNetwork ManagedRack Mountable

Key Product Advantages

The monitored capabilities of this PDU provide significant advantages for modern data center management. Remote monitoring of single- or three-phase voltage enables proactive maintenance and prevents downtime by identifying potential power issues before they affect critical systems.

Intelligent Load Distribution

Automatically balances electrical load across all three phases to prevent circuit overload and optimize power efficiency in high-density server environments.

  • Prevents phase imbalance
  • Maximizes power utilization
  • Reduces thermal stress

Comprehensive Remote Management

Offers multiple management interfaces including web-based HTTP/HTTPS access, command-line SSHv2, and SNMP integration for seamless incorporation into existing monitoring systems.

  • Web browser access
  • Command-line control
  • SNMP integration

Zero Rack Space Design

The 0U form factor mounts vertically in standard 19-inch racks without consuming valuable horizontal space, ideal for maximizing equipment density in constrained data centers.

  • Vertical mounting
  • No horizontal space used
  • Standard 19-inch compatibility

Deployment / Use Cases

This 36-outlet PDU is engineered for data center environments requiring high-density power distribution with monitoring capabilities. The three-phase 415V AC input makes it suitable for enterprise server rooms, colocation facilities, and cloud infrastructure deployments where reliable power distribution is critical.

The combination of CX and C13 outlets supports mixed equipment environments, from servers and storage arrays to networking gear and peripheral devices. The 0U vertical mounting design is particularly valuable in fully populated racks where horizontal space is at a premium.

High-Density Server Racks

Ideal for fully populated server racks in data centers, providing power to 36 devices while maintaining load balance across all three phases for optimal electrical efficiency.

Remote Monitoring Environments

Perfect for facilities requiring off-site power management, with comprehensive protocol support for integration into existing network management systems and dashboards.

Physical Profile

Designed for vertical rack mounting, this PDU features a slim 2.20-inch width that fits neatly in standard 19-inch rack enclosures. The 70-inch height provides ample outlet spacing for proper cable management, while the 2.50-inch depth ensures compatibility with most rack configurations without protruding into equipment space.

The physical profile is practical for deployment planning because the dimensions and weight are clearly defined: 0U, 2.20" (55.88 mm), 2.50" (63.50 mm). This helps confirm rack, shelf, desk, or cabinet fit before installation.

Dimensions
Width
2.20" (55.88 mm)
Depth
2.50" (63.50 mm)
Height
0U
Height70" (1778 mm)
Width2.20" (55.88 mm)
Depth2.50" (63.50 mm)
[custom-highlights]

Highlights

  • 36 total outlets with 18 CX and 18 C13 receptacles for versatile equipment connectivity
  • 415V AC three-phase input with 30A current capacity for high-power applications
  • 17.30 kW power rating supports demanding server and storage deployments
  • Monitored PDU with remote voltage monitoring capabilities
  • 0U vertical rack mount design conserves valuable horizontal space
  • Network management via RJ-45 with HTTP, HTTPS, SSHv2, and Telnet access
  • Enterprise security with TLSv1.2, SNMP v2c/v3, and TACACS+/RADIUS authentication
  • Circuit protection safeguards connected equipment from electrical anomalies
  • IEC 60309 3P+N+G 6Hr 30A input connector for reliable three-phase connection
  • Load balancing across all three phases prevents circuit overload
[/custom-highlights][custom-specifications]

Specifications

Specifications
ManufacturerLegrand Group
Manufacturer Part NumberC3S36RL-GPJE2MT2
Brand NameServer Technology
Product LinePRO3X
Product NamePRO3X 36-Outlet PDU
Product TypePDU
Technical Information
PDU TypeMonitored
PhaseThree Phase
Plug/Connector TypeIEC 60309 3P+N+G 6Hr 30A
Receptacle TypeCX,IEC 60320 C13
Receptacle Detail18 x CX,18 x IEC 60320 C13
Protection TypeCircuit Protection
Power Description
Input Voltage415 V AC
Power Rating (Watt)17.30 kW
Input Current30 A
Management
ManagementHTTP HTTPS TLSv1.2 SSHv2 Telnet SNMP v2c SNMP v3 (GET, SET, Traps) IPv4 IPv6 LDAPv3 LDAPS TACACS+ RADIUS FTP SFTP
Interfaces/Ports
Network (RJ-45)Yes
Physical Characteristics
Mount TypeRack-mountable
Rack Height0U
Height70" (1778 mm)
Width2.20" (55.88 mm)
Depth2.50" (63.50 mm)
[/custom-specifications][custom-faq]

FAQ

What is the input voltage and phase configuration for this PDU?

This Server Technology PRO3X PDU accepts 415V AC three-phase input through an IEC 60309 3P+N+G 6Hr 30A connector. The three-phase configuration provides balanced power distribution ideal for data center environments, with each phase carrying equal load to maximize electrical efficiency and prevent circuit overload in high-density server installations.

How many outlets does this PDU have and what types are they?

The PDU features 36 total outlets, consisting of 18 CX receptacles and 18 IEC 60320 C13 receptacles. This mixed configuration accommodates diverse equipment types commonly found in data centers, from servers and storage devices to networking equipment and peripherals, providing flexibility for various power cord requirements in rack-mounted environments.

What is the power rating and current capacity of this unit?

This PDU has a power rating of 17.30 kW with an input current capacity of 30A. This substantial power handling capability supports high-density server deployments where multiple devices require consistent, reliable power distribution without voltage drops or circuit overloads that could affect equipment performance.

How is this PDU mounted in a rack and what space does it require?

The PDU uses a 0U vertical mounting design that installs along the side or rear of standard 19-inch racks without consuming horizontal rack space. With dimensions of 70 inches high, 2.20 inches wide, and 2.50 inches deep, it fits neatly in most rack enclosures while providing ample outlet spacing for proper cable management in densely populated server environments.

What remote management capabilities does this monitored PDU offer?

This PDU provides comprehensive remote management through network connectivity via RJ-45. Management protocols include HTTP and HTTPS for web-based access, SSHv2 for secure command-line control, Telnet for legacy system compatibility, and SNMP v2c/v3 for integration with network monitoring systems. Security features include TLSv1.2 encryption and enterprise authentication through TACACS+ and RADIUS.

What type of protection does this PDU provide for connected equipment?

The PDU includes circuit protection to safeguard connected servers and networking equipment from electrical anomalies. This protection works in conjunction with the unit's load balancing capabilities, which automatically distribute electrical load evenly across all three phases to prevent circuit overloads and maintain stable power delivery to critical infrastructure in data center environments.

What power capacity is listed for this UPS?

The listed power specification is 17.30 kW, which helps position the unit for the right load level and installation role.

What voltage details are listed?

The listed power specification is 415 V AC, which helps position the unit for the right load level and installation role.

[/custom-faq]
Volume Discounts
Qty Price Available
Match Price Request

Found a lower price? Send us the link and we will do our best to match or beat it.

Request received. We will reply within 24 hours.
Fleet Network
Wholesale & B2B
Partner with Us

Looking to buy in bulk? We offer competitive pricing, dedicated support, and custom solutions for businesses of all sizes.

Volume Discounts

Tiered pricing structure designed to maximize your margins as you grow.

Dedicated Account Manager

Direct access to a specialist who understands your business needs.

Fast & Reliable Shipping

Priority processing and discounted shipping rates for bulk orders.

Request a Quote
Thank you!
Your request has been sent successfully.
Server Technology C3S36RL-GPJE2MT2 PRO3 x 36-Outlet PDU - Monitored - 415V AC Three Phase - 18 CX & 18 C13 Outlets - 0U Rack Mount
MSRP: $3,179.87
$3,179.87
$2,986.99
Save: $192.88 (6.07%)
Out of stock