Shipping included*
Exclusions
Additional shipping fees may apply in rare circumstances for deliveries outside standard service areas. In most cases, this only potentially affects shipments to the Northwest Territories and Yukon, as well as certain heavy or oversized items.
Server Technology C2S36TE-DCMFAM99 Smart PRO2 Monitored PDU - 36 Outlets - 18 C13 - 18 CX - 8. 6 kW - 230V AC - NEMA L15-30P - Rack-Mountable
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This Smart PRO2 PDU operates as a three-phase monitored unit with branch circuit protection and circuit breaker safeguards. The electrical specifications include 230V AC input voltage delivering 208V AC output, with 30A input current capacity supporting the full 8.60 kW power rating.
Network management capabilities are extensive, supporting HTTP/HTTPS with TLSv1.2 encryption, SNMPv2c/v3 for monitoring and configuration, SSHv2 and Telnet for secure command-line access, plus IPv4 and IPv6 network addressing. Additional management features include LDAPv3/LDAPS for directory services integration, TACACS+ and RADIUS for authentication, and FTP/SFTP for file transfers.
This section brings together practical product details such as PDU Type, Phase, Plug/Connector Type, Input Voltage, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
A strong technical summary explains how the product's interfaces, hardware profile, and operating characteristics work together in real deployment. Buyers often need this context to confirm compatibility with existing devices, expected performance in daily use, and whether installation will be straightforward for IT staff or end users.
Key Product Advantages
The Smart PRO2 PDU combines high-density power distribution with intelligent monitoring in a space-efficient rack design. Remote management capabilities reduce the need for physical access to power infrastructure, while comprehensive protection features safeguard connected equipment.
Comprehensive Monitoring
Monitor voltage, current, and power metrics remotely through multiple protocols including SNMP, HTTP/HTTPS, and SSH. The LED display provides local status visibility without network connectivity.
- Remote voltage monitoring
- Current and power tracking
- Local LED status display
High-Density Power Distribution
Thirty-six outlets in a compact 2U form factor maximize rack space utilization while supporting mixed equipment types through C13 and CX receptacle combinations.
- 36 outlets in minimal rack space
- Mixed C13 and CX receptacles
- Optimized rack density
Enterprise Management Integration
Support for industry-standard protocols enables integration with existing data center management systems, including SNMP for network management suites and LDAP for directory services.
- SNMP v2c/v3 compatibility
- LDAP/LDAPS integration
- TACACS+/RADIUS authentication
Deployment / Use Cases
This monitored PDU is designed for deployment in data centers, server rooms, and network closets where reliable power distribution with monitoring capabilities is essential. The three-phase power configuration and 8.60 kW capacity make it suitable for supporting high-density server racks, storage arrays, and networking equipment.
Typical applications include enterprise data centers requiring remote power monitoring, colocation facilities needing secure customer access controls, and IT environments with mixed equipment types benefiting from both C13 and CX outlet configurations. The rack-mountable design integrates seamlessly with standard 19-inch rack cabinets, while the compact 2.20-inch width preserves valuable rack space for additional equipment.
Data Center Power Distribution
Distribute three-phase power to server racks while monitoring consumption and status remotely through network management interfaces.
High-Density Server Environments
Support multiple servers and networking devices in compact rack configurations with 36 outlets and 8.60 kW power capacity.
Physical Profile
The PDU features a vertical rack-mountable design with dimensions of 70 inches in height, 2.20 inches in width, and 2.50 inches in depth. This 2U-width form factor maximizes outlet density while minimizing rack space consumption. The unit is constructed for data center environments with operating specifications supporting temperatures up to 140°F (60°C) and humidity ranges from 8% to 90%.
- Width
- 2.20" (55.88 mm)
- Depth
- 2.50" (63.50 mm)
- Height
- 70" (1778 mm)
What's in the Box
The package includes the PRO2 36-Outlets PDU unit with standard button mounts for rack installation.
Package contents include PRO2 36-Outlets PDU Standard Button Mounts, PRO2 36-Outlets PDU. These included items support setup, installation, and immediate deployment without needing to source the core bundled accessories separately.
Highlights
- 36 total outlets with 18 C13 and 18 CX receptacles for versatile equipment connectivity
- 8.60 kW power rating with 230V AC input and 30A current capacity
- Three-phase monitored PDU with remote management capabilities
- Network management via HTTP/HTTPS, SNMP, SSH, Telnet, IPv4/IPv6
- NEMA L15-30P input plug for three-phase power connections
- Rack-mountable design with 70" height and 2.20" width for space efficiency
- LED display for local status monitoring and diagnostics
- P-Lock locking receptacles prevent accidental disconnection
- Branch circuit protection with circuit breaker safeguards
- Operating temperature range up to 140°F (60°C) for data center environments
Specifications
| Specifications | |
|---|---|
| Manufacturer | Legrand Group |
| Manufacturer Part Number | C2S36TE-DCMFAM99 |
| Brand Name | Server Technology |
| Product Line | Smart |
| Product Series | PRO2 |
| Product Name | Smart PRO2 36-Outlets PDU |
| Product Type | PDU |
| Technical Information | |
| PDU Type | Monitored |
| Phase | Three Phase |
| Plug/Connector Type | NEMA L15-30P |
| Receptacle Type | IEC 60320 C13,CX |
| Receptacle Detail | 18 x IEC 60320 C13,18 x CX |
| Protection Type | Branch Circuit,Circuit Breaker,Circuit Protection |
| Locking Receptacles | P-Lock |
| Features | LED Display |
| Power Description | |
| Input Voltage | 230 V AC |
| Output Voltage | 208 V AC |
| Power Rating (Watt) | 8.60 kW |
| Input Current | 30 A |
| Management | |
| Management | HTTP/HTTPS TLSv1.2 SSHv2 Telnet SNMPv2c v3 (GET, SET, Traps) IPv4 IPv6 LDAPv3/LDAPS TACACS+ RADIUS FTP/SFTP DHCP RS-232 serial |
| Interfaces/Ports | |
| Network (RJ-45) | Yes |
| Physical Characteristics | |
| Mount Type | Rack-mountable,Cabinet-mountable |
| Height | 70" (1778 mm) |
| Width | 2.20" (55.88 mm) |
| Depth | 2.50" (63.50 mm) |
| Environmental Conditions | |
| Maximum Operating Temperature | 140°F (60°C) |
| Minimum Storage Temperature | -40°F (-40°C) |
| Maximum Storage Temperature | 185°F (85°C) |
| Minimum Operating Humidity | 8% |
| Maximum Operating Humidity | 90% |
| Miscellaneous | |
| Package Contents | PRO2 36-Outlets PDU Standard Button Mounts |
| Country of Origin | United States |
| Warranty | |
| Limited Warranty | 2 Year |
FAQ
What is the power capacity of this Server Technology PDU?
This Smart PRO2 PDU has a power rating of 8.60 kW (8,600 watts) with 230V AC input voltage and 30A input current. This capacity supports high-density server racks and equipment requiring substantial power distribution in data center environments.
How many outlets does this PDU provide and what types are they?
The PDU offers 36 total outlets configured as 18 IEC 60320 C13 receptacles and 18 CX receptacles. This mixed configuration supports various equipment types commonly found in data centers, from servers and networking gear to storage devices and other infrastructure components.
What input connector does this PDU use for power connection?
This PDU uses a NEMA L15-30P plug for three-phase power input. This connector type is standard for three-phase power distribution in North American data centers and commercial installations requiring 208-230V AC power delivery.
How can I monitor and manage this PDU remotely?
The PDU supports multiple network management protocols including HTTP/HTTPS with TLSv1.2 encryption, SNMPv2c and v3 for monitoring and configuration, SSHv2 and Telnet for command-line access, plus IPv4 and IPv6 addressing. Additional management features include LDAP/LDAPS integration, TACACS+/RADIUS authentication, and FTP/SFTP for file transfers.
Is this PDU designed for rack mounting?
Yes, this PDU is specifically designed for rack and cabinet mounting with a vertical form factor measuring 70 inches in height, 2.20 inches in width, and 2.50 inches in depth. The unit includes standard button mounts for secure installation in 19-inch rack cabinets, optimizing space utilization in data center environments.
What protection features does this PDU include?
The PDU incorporates branch circuit protection with circuit breaker safeguards to protect connected equipment from electrical faults. Additionally, it features P-Lock locking receptacles that prevent accidental disconnection in vibration-prone environments, ensuring reliable power delivery to critical infrastructure.
What power capacity is listed for this UPS?
The listed power specification is 8.60 kW, which helps position the unit for the right load level and installation role.
What voltage details are listed?
The listed power specification is 230 V AC, which helps position the unit for the right load level and installation role.