Shipping included*
Exclusions
Additional shipping fees may apply in rare circumstances for deliveries outside standard service areas. In most cases, this only potentially affects shipments to the Northwest Territories and Yukon, as well as certain heavy or oversized items.
Tripp Lite by Eaton SU6000RT4UTF SmartOnline EZ 6000VA/5400W Rack-Mount UPS - 6U - 208/240V Input - 16 Outlets - Hot-Swappable
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This UPS delivers 6 kVA (5400W) of power capacity, supporting equipment with a combined input current of up to 31.90A. It accepts 208V or 240V AC input and provides flexible output at 120V, 208V, or 240V AC, accommodating a wide range of server and network hardware. The integrated 2U low-voltage transformer ensures total equipment compatibility in diverse power setups.
Runtime is precisely defined: 2 minutes at full load and 8.5 minutes at half load, with a typical battery recharge time of 6 hours. The system is fully hot-swappable, allowing battery modules to be replaced without powering down connected equipment. Management is comprehensive via SNMP, serial, and USB interfaces, supported by the included PowerAlert software suite for monitoring and graceful shutdowns.
This section brings together practical product details such as Plug/Connector Type, Receptacle Type, Receptacle Detail, Load Capacity (VA), so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
Key Product Advantages
The SU6000RT4UTF combines high power density with operational resilience, making it a cornerstone for modern data center and network closet power protection.
Zero-Downtime Maintenance
The integrated maintenance bypass switch enables the entire UPS to be taken offline for service or replacement while connected equipment continues running on utility power, ensuring 100% uptime.
- Live replacement capability
- No service interruption
High-Density Power in Minimal Space
Packs 6kVA/5400W of capacity and 16 diverse outlets into a 6U rack space, including a detachable PDU and low-voltage transformer, maximizing power distribution in constrained racks.
- 6U total form factor
- Integrated PDU and transformer
User-Manageable Design
Batteries are completely user-hot-swappable without tools or technician assistance, reducing maintenance costs and complexity. Full SNMP, serial, and USB management provides remote monitoring and control.
- No service calls for battery swaps
- Multi-interface management
Deployment / Use Cases
This UPS is purpose-built for environments where power continuity is non-negotiable and rack space is at a premium. Its high-voltage input and robust output configuration make it ideal for protecting consolidated server racks, telecom switches, and network infrastructure in commercial and industrial settings.
Typical deployments include data center server racks, network operation centers (NOCs), telecommunications equipment cabinets, and industrial control systems. The ability to support mixed voltages (120V, 208V, 240V) from a single unit simplifies power design for heterogeneous equipment racks. The hot-swappable battery design and maintenance bypass are critical for environments that mandate 24/7 operation without scheduled downtime.
Physical Profile
The UPS occupies 6U of standard 19-inch rack space, with dimensions of 6.85" height, 17.50" width, and 20.07" depth. It weighs approximately 116.20 lb, requiring proper rack mounting and consideration for floor loading. The design includes integrated mounting rails (included) for secure installation. The compact 6U height for a 6000VA unit represents a high power-density form factor, conserving valuable rack real estate for additional equipment.
- Width
- 17.50" (444.50 mm)
- Depth
- 20.07" (509.78 mm)
- Height
- 6.85" (173.99 mm)
- Weight
- 116.20 lb (52707.43 g)
What's in the Box
The package includes all necessary components for immediate deployment and management.
Highlights
- 6000VA/5400W double-conversion online UPS for maximum power protection.
- True online operation with pure sine wave output and zero transfer time.
- Accepts 208V or 240V input; outputs 120V, 208V, or 240V AC.
- 16 total outlets: 8x NEMA 5-15R, 2x NEMA 5-15/20R, 4x NEMA L6-30R, 2x NEMA L6-20R.
- Hot-swappable batteries—user-replaceable without a technician.
- Integrated maintenance bypass switch for live UPS replacement with zero downtime.
- 6U rack-mountable form factor with included rail kit.
- Managed via SNMP, serial, and USB; includes PowerAlert software.
- 2-year limited warranty and RoHS environmental compliance.
Specifications
| Specifications | |
|---|---|
| Manufacturer | Eaton Corporation |
| Manufacturer Part Number | SU6000RT4UTF |
| Brand Name | Tripp Lite series |
| Product Line | SmartOnline |
| Product Series | EZ |
| Product Model | SU6000RT4UTF |
| Product Name | SmartOnline EZ SU6000RT4UTF 6000 VA Rack mountable UPS |
| Product Type | Double Conversion Online UPS |
| Technical Information | |
| Plug/Connector Type | NEMA L6-30P |
| Receptacle Type | NEMA 5-15R,NEMA 5-15/20R,NEMA L6-30R,NEMA L6-20R |
| Receptacle Detail | 8 x NEMA 5-15R,2 x NEMA 5-15/20R,4 x NEMA L6-30R,2 x NEMA L6-20R |
| Power Description | |
| Load Capacity (VA) | 6 kVA |
| Load Capacity (Watt) | 5.40 kW |
| Input Voltage | 208 V AC,240 V AC |
| Input Current | 31.90 A |
| Output Voltage | 120 V AC,208 V AC,240 V AC |
| Management | |
| Network Management | SNMP Manageable |
| Interfaces/Ports | |
| Serial Port | Yes |
| USB | Yes |
| Battery Information | |
| Backup/Run Time (Full Load) | 2 Minute |
| Backup/Run Time (Half Load) | 8.50 Minute |
| Hot Swappable | Yes |
| Typical Battery Recharge Time | 6 Hour |
| Physical Characteristics | |
| Height | 6.85" (173.99 mm) |
| Width | 17.50" (444.50 mm) |
| Depth | 20.07" (509.78 mm) |
| Rack Height | 6U |
| Form Factor | Rack-mountable |
| Weight (Approximate) | 116.20 lb (52707.43 g) |
| Miscellaneous | |
| Package Contents | SmartOnline EZ SU6000RT4UTF 6000 VA Rack mountable UPS PowerAlert Software Suite CD Rail Kit USB Cable Serial Cable EPO Cable |
| Software Included | PowerAlert Software Suite |
| Country of Origin | China |
| Environmentally Friendly | Yes |
| Environmental Compliance | Restriction of Hazardous Substances (RoHS) |
| Warranty | |
| Limited Warranty | 2 Year |
User Manual
FAQ
What is the power capacity of the SU6000RT4UTF UPS?
This UPS has a load capacity of 6000 Volt-Amps (VA), which equates to 5400 Watts (5.40 kW). This rating defines the maximum amount of equipment it can support, making it suitable for protecting multiple servers, switches, or telecom systems in a single rack.
What input voltage does this UPS require?
The SU6000RT4UTF is designed for high-voltage environments and requires a 208V or 240V AC input source. It draws a maximum input current of 31.90A. This makes it compatible with standard three-phase or high-voltage single-phase power circuits common in data centers and commercial buildings.
How many outlets does it have and what types?
It provides 16 outlets in total for connecting protected equipment. The outlet mix includes: 8 standard NEMA 5-15R (15A, 125V) outlets, 2 NEMA 5-15/20R (20A, 125V) outlets, 4 NEMA L6-30R (30A, 250V) locking outlets, and 2 NEMA L6-20R (20A, 250V) locking outlets. This variety supports a wide range of server, network, and industrial device plugs.
What is the battery runtime and recharge time?
At full load (5400W), the battery provides approximately 2 minutes of runtime. At half load (2700W), runtime extends to about 8.5 minutes. After a complete discharge, the batteries typically recharge to 90% capacity within 6 hours when the UPS is connected to mains power and in standby mode.
What does 'hot-swappable' mean for this UPS?
The batteries are user-hot-swappable. This means you can safely remove and replace the battery modules while the UPS is operating and supporting connected equipment. No service call or certified technician is required, which minimizes maintenance downtime and reduces long-term ownership costs.
How is this UPS managed and monitored?
It offers multiple management interfaces: SNMP for network-based monitoring and control, a serial port for direct or console server connection, and a USB port for local PC management. The included PowerAlert Software Suite enables features like runtime monitoring, graceful server shutdown during extended outages, and environmental/security monitoring when used with optional sensors.
What power capacity is listed for this UPS?
The listed power specification is 6 kVA, which helps position the unit for the right load level and installation role.
What voltage details are listed?
The listed power specification is 208 V AC,240 V AC, which helps position the unit for the right load level and installation role.