Shipping included*
Exclusions
Additional shipping fees may apply in rare circumstances for deliveries outside standard service areas. In most cases, this only potentially affects shipments to the Northwest Territories and Yukon, as well as certain heavy or oversized items.
Tripp Lite by Eaton SU8000RT3UHW Tripp Lite SmartOnline 8000VA/6400W Double Conversion UPS - 6U Rack/Tower - 6 Min Full Load Runtime
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This SmartOnline UPS employs true double-conversion technology, where incoming AC power is converted to DC, then back to clean, regulated AC power. This isolates connected loads from all common power problems, including surges, sags, harmonics, and frequency variations. The unit accepts a 220V AC input and provides configurable output voltages of 220V, 230V, or 240V AC to match regional power standards.
With an 8 kVA/6.4 kW capacity and a 0.9 power factor, it efficiently supports high-density server racks, storage arrays, networking gear, and industrial control systems. The battery system offers a 6-minute runtime at full load and extends to 15 minutes at half load, providing adequate time for backup generators to start or for orderly system shutdowns. A typical full recharge completes within 8 hours.
This section brings together practical product details such as Plug/Connector Type, Load Capacity (VA), Load Capacity (Watt), Input Voltage, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
Key Product Advantages
The SU8000RT3UHW combines industrial-grade power conditioning with deployment flexibility and proactive management tools. Its design prioritizes reliability and serviceability in environments where uptime is non-negotiable.
Zero Transfer Time Protection
Double-conversion topology ensures connected equipment never experiences a break in power, even during blackouts or severe brownouts, eliminating the risk of data corruption or hardware stress from switching events.
- Isolates loads from grid anomalies
- Provides continuous regulated output
Modular Hot-Swap Design
Power and battery modules can be replaced or expanded without taking the UPS offline, enabling proactive maintenance and future capacity upgrades without interrupting protected loads.
- Supports live maintenance
- Facilitates easy battery replacement
Comprehensive Management Suite
SNMP, USB, and RS232 interfaces, along with optional SNMP/WEB and contact-closure cards, allow for integration into existing network monitoring systems, remote management, and automated emergency power-off (EPO) sequences.
Deployment / Use Cases
This 8000VA UPS is built for scenarios requiring robust, clean power for sensitive and high-availability infrastructure. Its capacity and form factor make it a fit for centralized protection of multiple devices within a single enclosure or location.
In a data center or server room, it can safeguard a full rack of servers, switches, and storage units. For industrial settings, it protects programmable logic controllers (PLCs), HMIs, and instrumentation from damaging voltage fluctuations. The tower configuration suits smaller IT closets or offices housing critical file servers and network hardware.
Data Center & Server Rack Power
Provides backup power and conditioning for high-density server and network equipment racks, ensuring business continuity during utility failures.
Industrial Control System Support
Protects manufacturing and process control electronics from dirty power that can cause erratic behavior, data loss, or premature equipment failure.
Physical Profile
The UPS comprises a 3U power module and a separate 3U external battery pack, totaling a 6U rack footprint. Each unit measures 5.14" H x 17.50" W x 25" D. The included four-post rackmount rails and tower stands provide secure installation in either orientation. The hardwired 3-wire connection requires professional installation by a qualified electrician to local electrical codes.
The physical profile is practical for deployment planning because the dimensions and weight are clearly defined: 5.14" (130.56 mm), 17.50" (444.50 mm), 25" (635 mm), 55 lb (24947.58 g). This helps confirm rack, shelf, desk, or cabinet fit before installation.
- Width
- 17.50" (444.50 mm)
- Depth
- 25" (635 mm)
- Height
- 5.14" (130.56 mm)
- Weight
- 55 lb (24947.58 g)
What's in the Box
The package includes all necessary components for rack-mount or tower deployment, along with management software.
Highlights
- 8000VA / 6400W double conversion online UPS with pure sine wave output
- 6-minute runtime at full load, 15-minute runtime at half load
- 6U rack/tower form factor with included rails and tower stands
- Hot-swappable power and battery modules for maintenance without downtime
- SNMP, USB, and RS232 management interfaces
- Input: 220V AC; Configurable output: 220V/230V/240V AC
- Includes PowerAlert management and shutdown software
- Backed by a 2-year limited warranty
Specifications
| Specifications | |
|---|---|
| Manufacturer | Eaton Corporation |
| Manufacturer Part Number | SU8000RT3UHW |
| Brand Name | Tripp Lite series |
| Product Line | SmartOnline |
| Product Model | SU8000RT3UHW |
| Product Name | SmartOnline SU8000RT3UHW 8000VA Tower/Rack-mountable UPS |
| Product Type | Double Conversion Online UPS |
| Technical Information | |
| Plug/Connector Type | Hard Wire 3-wire |
| Power Description | |
| Load Capacity (VA) | 8 kVA |
| Load Capacity (Watt) | 6.40 kW |
| Input Voltage | 220 V AC |
| Output Voltage | 240 V AC,220 V AC,230 V AC |
| Management | |
| Network Management | SNMP Manageable |
| Battery Information | |
| Backup/Run Time (Full Load) | 6 Minute |
| Backup/Run Time (Half Load) | 15 Minute |
| Hot Swappable | Yes |
| Typical Battery Recharge Time | 8 Hour |
| Physical Characteristics | |
| Height | 5.14" (130.56 mm) |
| Width | 17.50" (444.50 mm) |
| Depth | 25" (635 mm) |
| Rack Height | 6U |
| Form Factor | Rack/Tower |
| Weight (Approximate) | 55 lb (24947.58 g) |
| Miscellaneous | |
| Package Contents | SmartOnline SU8000RT3UHW 8000VA Tower/Rack-mountable UPS 3U power module with detachable hot-swap PDU input/output panel and bypass switch 3U external battery pack Two sets of 4 post rackmount rails (one for each of the 3U components) One set of tower stands for upright tower con |
| Software Included | PowerAlert Software |
| Country of Origin | China |
| Warranty | |
| Limited Warranty | 2 Year |
User Manual
FAQ
What is the power capacity of this Tripp Lite UPS?
The SmartOnline SU8000RT3UHW has a load capacity of 8000 VA (8 kVA) and 6400 watts. With a 0.9 power factor, it can support a substantial amount of connected equipment, making it suitable for protecting server racks, network gear, or industrial control systems that demand high, clean power.
How long will this UPS run on battery power?
At full rated load (6400W), the battery runtime is 6 minutes. At a half load (3200W), the runtime extends to approximately 15 minutes. This provides a critical window for initiating backup generators or executing a controlled shutdown of protected systems to prevent data loss or hardware damage.
Can this UPS be installed in a server rack?
Yes, the SU8000RT3UHW is designed for both rack-mount and tower deployment. The system consists of a 3U power module and a separate 3U external battery pack, requiring a total of 6U of rack space. The package includes two sets of four-post rackmount rails for secure installation in a standard equipment rack.
What management features are available?
The UPS includes USB and RS232 ports for local management with the included PowerAlert software. It is also SNMP manageable for integration into network monitoring systems. Optional SNMP/WEB and contact-closure cards are available for advanced remote monitoring, web interface access, and integration with emergency power-off (EPO) systems.
Are the batteries hot-swappable?
Yes, both the power module and the external battery pack feature hot-swappable designs. This allows you to replace or service these components without powering down the UPS or disconnecting the protected loads, which is essential for maintaining uptime in critical environments.
What type of power output does this UPS provide?
This is a double conversion online UPS, which means it provides a pure sine wave output. This is the cleanest form of AC power and is fully compatible with sensitive electronic equipment, including servers with active PFC power supplies. It ensures stable operation and prevents potential issues caused by simulated or stepped sine waves from lower-end UPS models.
What power capacity is listed for this UPS?
The listed power specification is 8 kVA, which helps position the unit for the right load level and installation role.
What voltage details are listed?
The listed power specification is 220 V AC, which helps position the unit for the right load level and installation role.