APC by Schneider Electric SYA16K16P Symmetra LX 16kVA N+1 Tower UPS - Double Conversion Online - SNMP Manageable - 6 Min Full Load - 208V AC Input
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This Symmetra LX UPS employs double conversion online technology, providing the highest level of power isolation and conditioning by continuously converting incoming AC power to DC and then back to a clean, regulated AC output. This topology ensures zero transfer time to battery during outages and protects connected equipment from all nine common power problems, including surges, sags, and frequency variations.
The unit features a single hard-wired 4-wire (2PH+N+G) receptacle for direct connection to electrical infrastructure, supporting a 208V AC input. It offers overload protection and maintains a sine wave output essential for the stable operation of servers, storage, and networking gear. Thermal management is handled with a dissipation rating of 4995 BTU/h, and the system operates reliably in environments up to 104°F (40°C).
This section brings together practical product details such as Plug/Connector Type, Receptacle Type, Receptacle Detail, Load Capacity (VA), so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
Key Product Advantages
The Symmetra LX platform is distinguished by its modular, scalable design and high-reliability architecture. Beyond the raw power capacity, the system's manageability and serviceability features make it a strategic choice for IT environments where downtime is not an option. The included Web/SNMP card provides a direct network interface for configuration, real-time status monitoring, and historical logging of power events.
For buyers comparing similar models, the strongest advantage is usually the balance between dependable day-to-day operation and a simpler rollout experience. That means less time spent troubleshooting fit, compatibility, or user adoption after installation, which is especially important for shared business environments and repeat purchasing decisions.
Deployment / Use Cases
This UPS is engineered for installations where power quality and availability are paramount. Its double conversion technology makes it suitable for environments with unstable grid power or sensitive medical and laboratory equipment. The tower design offers flexibility in placement, not requiring dedicated rack space, which is advantageous in mixed-use IT closets or equipment rooms.
Server Room & Edge Data Center Protection
Ideal for protecting a rack or small cluster of servers, storage arrays, and core networking switches in a server room or at the edge of a larger data center network. The 16 kVA capacity and tower form factor suit environments where a full rack-mount system is not required.
- Provides clean power to blade servers and high-performance computing nodes.
- Protects virtualization hosts and their associated storage from data corruption due to power events.
Critical Network Infrastructure
Ensures continuous operation of network operations centers (NOCs), telecom equipment, and security system hardware that must remain online 24/7. The SNMP capability allows integration with NMS tools like Nagios or SolarWinds for centralized oversight.
- Backs up core routers, switches, and firewalls.
- Maintains uptime for VoIP systems and wireless access point controllers.
Physical Profile
The UPS is housed in a substantial tower enclosure with a black and silver finish, measuring 36.89" high, 19.02" wide, and 28.58" deep (937 x 483 x 726 mm). With an approximate weight of 678.45 lbs (307.7 kg), it is a floor-standing unit that requires consideration for floor loading and placement during installation. The form factor provides stability and accommodates the internal battery banks and power electronics, with dimensions designed for serviceability and airflow.
- Width
- 19.02" (483 mm)
- Depth
- 28.58" (726 mm)
- Height
- 36.89" (937 mm)
- Weight
- 678.45 lb (307739.74 g)
What's in the Box
The package includes all necessary components for setup and operation.
Package contents include Symmetra LX 16kVA Scalable to 16kVA N+1 Tower UPS CD with software Installation guide User manual Web/SNMP management card, Symmetra LX 16kVA Scalable to 16kVA N+1 Tower UPS. These included items support setup, installation, and immediate deployment without needing to source the core bundled accessories separately.
Highlights
- 16 kVA double conversion online UPS for maximum power protection.
- N+1 internal redundancy for increased power availability.
- SNMP manageable with included Web/SNMP management card.
- 6-minute runtime at full load (16 kVA); 17.1 minutes at half load.
- 208V AC input with 120V/208V AC sine wave output.
- Tower form factor for flexible floor-standing deployment.
- Spill-proof, maintenance-free lead-acid batteries.
- Includes a 2-year repair or replace warranty.
- RoHS compliant and manufactured in the United States.
Specifications
| Specifications | |
|---|---|
| Manufacturer | Schneider Electric SA |
| Manufacturer Part Number | SYA16K16P |
| Brand Name | APC by Schneider Electric |
| Product Line | Symmetra |
| Product Series | LX |
| Product Name | Symmetra LX 16kVA Scalable to 16kVA N+1 Tower UPS |
| Product Type | Double Conversion Online UPS |
| Technical Information | |
| Plug/Connector Type | Hard Wire 4-wire |
| Receptacle Type | Hard Wire 4-wire (2PH+N+G) |
| Receptacle Detail | 1 x Hard Wire 4-wire (2PH+N+G) |
| Number of Battery & Surge Outlets | 1 |
| Overload Protection | Yes |
| Power Description | |
| Load Capacity (VA) | 16 kVA |
| Input Voltage | 208 V AC |
| Output Voltage | 120 V AC,208 V AC |
| Waveform Type | Sine Wave |
| Management | |
| Network Management | SNMP Manageable |
| Battery Information | |
| Battery Characteristics | Spill-proof/Maintenance-free |
| Battery Chemistry | Lead Acid |
| Backup/Run Time (Full Load) | 6 Minute |
| Backup/Run Time (Half Load) | 17.10 Minute |
| Typical Battery Recharge Time | 3 Hour |
| Environmental Conditions | |
| Maximum Operating Temperature | 104°F (40°C) |
| Thermal Dissipation | 4995 BTU/h |
| Physical Characteristics | |
| Product Color | Black,Silver |
| Form Factor | Tower |
| Height | 36.89" (937 mm) |
| Width | 19.02" (483 mm) |
| Depth | 28.58" (726 mm) |
| Weight (Approximate) | 678.45 lb (307739.74 g) |
| Miscellaneous | |
| Package Contents | Symmetra LX 16kVA Scalable to 16kVA N+1 Tower UPS CD with software Installation guide User manual Web/SNMP management card |
| Country of Origin | United States |
| Environmentally Friendly | Yes |
| Environmental Compliance | Restriction of Hazardous Substances (RoHS) |
| Warranty | |
| Limited Warranty | 2 Year |
| Additional Warranty Information | 2 years repair or replace |
User Manual
FAQ
What does 'N+1' mean in this UPS model?
N+1 refers to internal redundancy within the UPS. 'N' represents the number of power modules needed to support the connected load. The '+1' is an extra, redundant module. If one power module were to fail, the extra module can immediately take over, allowing the UPS to continue operating at full capacity without interruption. This design significantly enhances system reliability and allows for maintenance during operation.
What is the input voltage requirement for this Symmetra LX UPS?
This UPS requires a 208 Volt AC input. It is designed to be hard-wired directly into a compatible electrical circuit using a 4-wire (2 phase + neutral + ground) connection. It is not a plug-and-play unit for standard 120V outlets and must be installed by a qualified electrician to ensure proper and safe connection to your building's electrical infrastructure.
How long will this UPS run on battery power?
At its maximum rated load of 16 kVA, the internal batteries provide 6 minutes of backup runtime. At a reduced load of approximately 8 kVA (half load), the runtime extends to 17.1 minutes. The actual runtime for your specific equipment will depend on the total wattage drawn by all connected devices. The system is also runtime-scalable, meaning you can add external battery modules to achieve longer backup times if needed.
How is this UPS managed and monitored?
The unit is SNMP manageable. It includes a Web/SNMP management card that, once installed and connected to your network, provides a web interface for configuration and monitoring. This allows IT staff to check status, view event logs, configure alerts, and perform shutdown commands for connected servers remotely from any standard web browser or through network management systems that support SNMP.
What type of power output does it provide?
The UPS provides a pure sine wave output, which is the same quality of power supplied by the utility grid. This is essential for the safe and efficient operation of sensitive server power supplies, networking equipment, and other active PFC (Power Factor Corrected) loads. It can output power at either 120V AC or 208V AC, depending on how the connected equipment is configured and wired.
What is included in the warranty?
APC by Schneider Electric provides a 2-year warranty from the date of purchase. The warranty covers repair or replacement of the unit, including the internal batteries, in the event of a defect in materials or workmanship. It is a comprehensive warranty that supports the product's role in protecting critical business equipment.
What power capacity is listed for this UPS?
The listed power specification is 16 kVA, which helps position the unit for the right load level and installation role.
How many outlets are available?
The product includes 1, which helps buyers understand how many connected devices it can support in its intended deployment.