Eaton T17C19260-3-009 ePDU 6-Outlet 17. 3kW Horizontal PDU - 6 x IEC C19 - 230V AC - 1U Rack-Mountable
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This Eaton ePDU features a 17.30 kW power rating with 230V AC input and 240V AC output, providing voltage regulation for connected equipment. The six IEC 60320 C19 receptacles accommodate high-power server and networking devices with standardized international connectors.
Built-in spike and surge protection safeguards sensitive electronics from power anomalies, while the RoHS-compliant construction meets environmental standards. The horizontal mounting orientation and 1U rack height ensure seamless integration into standard 19-inch server racks.
This section brings together practical product details such as Receptacle Type, Receptacle Detail, Protection Type, Input Voltage, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
A strong technical summary explains how the product's interfaces, hardware profile, and operating characteristics work together in real deployment. Buyers often need this context to confirm compatibility with existing devices, expected performance in daily use, and whether installation will be straightforward for IT staff or end users.
Key Product Advantages
The Eaton T17C19260-3-009 delivers high-density power distribution with enterprise-grade reliability. Its 17.3 kW capacity supports power-intensive equipment while maintaining a minimal 1U rack footprint, optimizing valuable data center real estate.
High-Power Capacity
With 17.30 kW rating, this PDU handles demanding server and networking equipment loads without compromising performance or requiring additional units.
- Supports high-density server racks
- Eliminates power bottlenecks
- Reduces total PDU count needed
Robust Protection
Integrated spike and surge protection defends connected equipment against voltage transients and electrical disturbances that can cause hardware damage or downtime.
- Prevents equipment damage
- Reduces maintenance costs
- Enhances system reliability
Space-Efficient Design
The 1U horizontal form factor occupies minimal rack space while delivering full 17.3 kW capacity, allowing more equipment in the same footprint.
- Maximizes rack utilization
- Simplifies cable management
- Facilitates airflow optimization
Deployment / Use Cases
This Eaton ePDU is ideal for data centers, server rooms, and network closets where reliable high-power distribution is essential. Its 17.3 kW capacity and six IEC C19 outlets make it suitable for powering rack-mounted servers, storage arrays, and networking switches in enterprise environments.
The horizontal 1U design works particularly well in standard 19-inch server racks, providing clean power distribution without consuming valuable vertical space. IT managers can deploy multiple units across server racks to create redundant power paths or distribute loads efficiently.
Data Center Power Distribution
Deploy in server racks to distribute 230V AC power to multiple high-power devices from a single circuit, simplifying power management and reducing cable clutter.
High-Density Server Installations
Support blade servers, high-performance computing nodes, and storage systems that require substantial power while maintaining organized rack layouts.
Physical Profile
The Eaton T17C19260-3-009 measures 1.70 inches (43.18 mm) in height, 19 inches (482.60 mm) in width, and 7 inches (177.80 mm) in depth, fitting standard 1U rack spaces. Its horizontal orientation provides optimal cable routing and airflow management in server racks. The RoHS-compliant construction ensures environmental responsibility while delivering durable performance in data center conditions.
The physical profile is practical for deployment planning because the dimensions and weight are clearly defined: 1U, 19" (482.60 mm), 7" (177.80 mm). This helps confirm rack, shelf, desk, or cabinet fit before installation.
- Width
- 19" (482.60 mm)
- Depth
- 7" (177.80 mm)
- Height
- 1U
Highlights
- 17.30 kW power capacity for high-density equipment
- Six IEC 60320 C19 outlets for high-power devices
- 230V AC input with 240V AC output voltage regulation
- Built-in spike and surge protection for equipment safety
- Horizontal 1U rack-mountable design
- RoHS-compliant environmentally friendly construction
- 19-inch width for standard server rack compatibility
- Compact 7-inch depth for space-constrained installations
Specifications
| Specifications | |
|---|---|
| Manufacturer | Eaton Corporation |
| Manufacturer Part Number | T17C19260-3-009 |
| Brand Name | Eaton |
| Product Line | ePDU |
| Product Model | T17C19260-3-009 |
| Product Name | ePDU T17C19260-3-009 6-Outlets 17.3kW PDU |
| Product Type | PDU |
| Technical Information | |
| Receptacle Type | IEC 60320 C19 |
| Receptacle Detail | 6 x IEC 60320 C19 |
| Protection Type | Spike Protection,Surge Protection |
| Power Description | |
| Input Voltage | 230 V AC |
| Output Voltage | 240 V AC |
| Power Rating (Watt) | 17.30 kW |
| Physical Characteristics | |
| Mounting Orientation | Horizontal |
| Mount Type | Rack-mountable |
| Rack Height | 1U |
| Height | 1.70" (43.18 mm) |
| Width | 19" (482.60 mm) |
| Depth | 7" (177.80 mm) |
| Miscellaneous | |
| Environmentally Friendly | Yes |
| Environmental Compliance | Restriction of Hazardous Substances (RoHS) |
FAQ
What is the power capacity of this Eaton ePDU?
The Eaton T17C19260-3-009 ePDU has a 17.30 kW power rating, providing substantial capacity for powering multiple high-demand servers, storage systems, or networking equipment in data center environments. This capacity supports equipment with significant power requirements while maintaining stable voltage output.
How many outlets does this PDU have and what type are they?
This Eaton ePDU features six IEC 60320 C19 outlets, which are designed for high-power equipment typically found in data centers. The C19 connectors support devices requiring up to 16A current, making them suitable for servers, switches, and other enterprise hardware with substantial power needs.
What input voltage does this Eaton PDU require?
The Eaton T17C19260-3-009 requires 230V AC input voltage, which is common in commercial and data center power systems. It delivers 240V AC output to connected equipment, providing slight voltage regulation while maintaining compatibility with standard server and networking hardware power supplies.
Is this PDU rack-mountable and what are its dimensions?
Yes, this Eaton ePDU is designed for rack mounting with a horizontal orientation. It occupies 1U of rack space with dimensions of 1.70 inches (43.18 mm) in height, 19 inches (482.60 mm) in width, and 7 inches (177.80 mm) in depth, fitting standard 19-inch server racks while maximizing space efficiency.
Does this Eaton PDU include surge protection?
Yes, the Eaton T17C19260-3-009 includes both spike and surge protection to safeguard connected equipment from voltage transients and electrical disturbances. This protection helps prevent damage to sensitive servers and networking hardware, reducing downtime and maintenance costs in critical IT environments.
What environmental standards does this Eaton ePDU meet?
This Eaton ePDU is RoHS (Restriction of Hazardous Substances) compliant and environmentally friendly. RoHS compliance ensures the unit meets strict standards for limiting hazardous materials, making it suitable for deployment in environmentally conscious organizations and data centers with sustainability initiatives.
What power capacity is listed for this UPS?
The listed power specification is 17.30 kW, which helps position the unit for the right load level and installation role.
What voltage details are listed?
The listed power specification is 230 V AC, which helps position the unit for the right load level and installation role.