Shipping included*
Exclusions
Additional shipping fees may apply in rare circumstances for deliveries outside standard service areas. In most cases, this only potentially affects shipments to the Northwest Territories and Yukon, as well as certain heavy or oversized items.
Eaton T9092B-CBSF ePDU T992 12-Outlet 3. 33kW Rack PDU - IEC C20 Input - 12x C13 Outlets - 120/230V AC - 1U Horizontal Mount
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This Eaton ePDU operates with a 3.33 kilowatt power rating, handling input voltages of 120V AC and 230V AC with an input range of 125-240V AC. The output delivers consistent 240V AC power through twelve IEC 60320 C13 receptacles, fed by a single IEC 60320 C20 input connector.
Built-in surge and spike protection safeguards connected servers, networking gear, and storage systems from power anomalies. The dual voltage capability allows deployment in various geographic regions and power configurations without requiring hardware modifications.
Relevant factors for this section include Plug/Connector Type, Receptacle Type, Receptacle Detail, Input Voltage. When those points are considered together, they give buyers a clearer picture of how the product is equipped, how it fits into deployment, and what kind of day-to-day role it is meant to support.
A strong technical summary explains how the product's interfaces, hardware profile, and operating characteristics work together in real deployment. Buyers often need this context to confirm compatibility with existing devices, expected performance in daily use, and whether installation will be straightforward for IT staff or end users.
Key Product Advantages
The Eaton T9092B-CBSF combines high-density power distribution with enterprise-grade protection in a compact 1U form factor. Its dual voltage input capability provides deployment flexibility across different power standards, while the twelve C13 outlets support multiple server and network devices from a single power source.
High-Density Power Distribution
Twelve IEC C13 outlets deliver power to multiple servers, switches, and storage units while conserving valuable rack space through efficient 1U horizontal mounting.
- 12 outlets in 1U space
- IEC C13 standard connectors
- Horizontal mounting orientation
Voltage Flexibility
Accepts both 120V and 230V input voltages with a 125-240V AC range, enabling deployment in diverse power environments without hardware changes.
- 120V/230V dual voltage
- 125-240V input range
- 240V output consistency
Enterprise Protection
Integrated surge and spike protection defends sensitive IT equipment from power anomalies that can cause data loss, hardware damage, or system downtime.
- Surge protection
- Spike protection
- Continuous operation safeguard
Deployment / Use Cases
This Eaton ePDU is purpose-built for data center racks, server rooms, network closets, and telecom installations where reliable, high-density power distribution is essential. The 1U horizontal form factor integrates seamlessly into standard 19-inch racks alongside servers, switches, and storage arrays.
Ideal for powering server clusters, network equipment stacks, or storage systems that require multiple C13 power connections in a compact footprint. The dual voltage input makes it suitable for international deployments or facilities with mixed power infrastructure, while the surge protection ensures equipment longevity in environments with unstable power quality.
Data Center Server Racks
Power multiple 1U or 2U servers in a single rack with consistent 240V output, maximizing power density while maintaining clean cable management through standardized IEC connectors.
Network Equipment Installations
Distribute power to switches, routers, and other networking gear in telecom rooms or network closets, with surge protection safeguarding critical connectivity infrastructure.
Physical Profile
The Eaton T9092B-CBSF occupies minimal rack space with 1U height (1.70 inches/43.18 mm) and standard 19-inch width (482.60 mm). The 5-inch (127 mm) depth allows installation in shallow or deep racks without protruding beyond equipment. Horizontal mounting orientation provides optimal weight distribution and cable routing, while the compact dimensions maximize usable rack space for servers and networking equipment.
The physical profile is practical for deployment planning because the dimensions and weight are clearly defined: 1U, 19" (482.60 mm), 5" (127 mm). This helps confirm rack, shelf, desk, or cabinet fit before installation.
- Width
- 19" (482.60 mm)
- Depth
- 5" (127 mm)
- Height
- 1U
Highlights
- 3.33 kW power capacity for high-density server deployments
- 12 IEC C13 outlets support multiple servers and network devices
- Dual voltage input (120V/230V AC) for flexible installation
- 1U horizontal rack mounting conserves valuable rack space
- Surge and spike protection for equipment safety
- IEC 60320 C20 input connector with C13 output receptacles
- 125-240V AC input range accommodates various power standards
- 240V AC output delivers consistent power to connected equipment
- RoHS compliant for environmental responsibility
- Manufactured in the United States
Specifications
| Specifications | |
|---|---|
| Manufacturer | Eaton Corporation |
| Manufacturer Part Number | T9092B-CBSF |
| Brand Name | Eaton |
| Product Line | ePDU |
| Product Series | T992 |
| Product Model | T9092B-CBSF |
| Product Name | ePDU T992 T9092B-CBSF 12-Outlets 3.33kW PDU |
| Product Type | PDU |
| Technical Information | |
| Plug/Connector Type | IEC 60320 C20 |
| Receptacle Type | IEC 60320 C13 |
| Receptacle Detail | 12 x IEC 60320 C13 |
| Protection Type | Surge Protection,Spike Protection |
| Power Description | |
| Input Voltage | 120 V AC,230 V AC |
| Input Voltage Range | 125 V AC - 240 V AC |
| Output Voltage | 240 V AC |
| Power Rating (Watt) | 3.33 kW |
| Physical Characteristics | |
| Mounting Orientation | Horizontal |
| Mount Type | Rack-mountable |
| Rack Height | 1U |
| Height | 1.70" (43.18 mm) |
| Width | 19" (482.60 mm) |
| Depth | 5" (127 mm) |
| Miscellaneous | |
| Country of Origin | United States |
| Environmentally Friendly | Yes |
| Environmental Compliance | Restriction of Hazardous Substances (RoHS) |
FAQ
What is the power capacity of this Eaton ePDU?
The Eaton T9092B-CBSF ePDU delivers 3.33 kilowatts (3330 watts) of power capacity. This rating supports high-density server deployments and multiple network devices simultaneously, making it suitable for data center racks and server rooms where substantial power distribution is required.
How many outlets does this PDU have and what type are they?
This Eaton ePDU features twelve IEC 60320 C13 output receptacles. These standard data center connectors are commonly used for servers, switches, and storage devices. The input connection is a single IEC 60320 C20 plug, which provides power to all twelve outlets from a single source.
What input voltages does this Eaton PDU support?
The Eaton T9092B-CBSF supports dual voltage input of 120V AC and 230V AC, with an operational range of 125-240V AC. This flexibility allows deployment in different geographic regions and power infrastructures without hardware modifications, providing 240V AC output to connected equipment regardless of input voltage.
What rack space does this PDU require for installation?
This Eaton ePDU requires 1U of vertical rack space with horizontal mounting orientation. The physical dimensions are 1.70 inches (43.18 mm) height, 19 inches (482.60 mm) width, and 5 inches (127 mm) depth. The compact 1U form factor maximizes usable rack space for servers and networking equipment.
Does this Eaton PDU include power protection features?
Yes, the Eaton T9092B-CBSF includes both surge protection and spike protection. These features safeguard connected servers, networking gear, and storage systems from power anomalies that can cause data loss, hardware damage, or system downtime in data center and server room environments.
What type of environments is this Eaton ePDU designed for?
This Eaton ePDU is designed for data center racks, server rooms, network closets, and telecom installations. The 1U horizontal form factor, dual voltage input, and twelve C13 outlets make it ideal for powering server clusters, network equipment stacks, or storage systems that require reliable, high-density power distribution in rack-mounted environments.