Tripp Lite by Eaton SU3000RTXLCD2UN SmartOnline 3000VA/2700W 2U Rack-mount UPS - 120V AC Input - Pure Sine Wave - LCD Display
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This double-conversion online UPS provides full isolation from raw AC line power, continuously converting incoming AC to DC and then back to a clean, regulated AC output. The pure sine wave output is essential for sensitive electronic loads, including servers with active PFC power supplies. With a 3 kVA/2700W capacity, it supports substantial equipment loads while offering runtime of 4.1 minutes at full load and 11.3 minutes at half load.
The unit operates on a single-phase, 60 Hz input with a wide input voltage range of 100-127V AC and provides adjustable output voltages from 100V to 127V AC. It includes an EMI/RFI noise filter and a 570 J surge energy rating for additional protection. The 72V DC battery system is hot-swappable and user-replaceable, supporting continuous operation during maintenance.
Key Product Advantages
The SmartOnline SU3000RTXLCD2UN combines high power capacity with advanced management and robust physical design for reliable data center and server room protection. Its double-conversion architecture ensures output power is always clean and stable, regardless of input conditions.
Zero Transfer Time Protection
Double-conversion online topology eliminates transfer switches, providing seamless power during outages or fluctuations without any break in output power to connected equipment.
- Continuous power conditioning
- No switching delay during outages
- Ideal for sensitive server loads
Comprehensive Remote Management
SNMP/HTTP remote monitoring capabilities allow IT staff to monitor UPS status, configure settings, and receive alerts from anywhere on the network.
- Web-based management interface
- SNMP v1/v3 support
- Remote shutdown capabilities
Maintenance-Friendly Design
Hot-swappable batteries enable replacement without powering down connected equipment, while the 2U rack-mount form factor optimizes space in standard server racks.
- User-replaceable battery modules
- 2U rack height compatibility
- Tower support stands included
Deployment / Use Cases
This UPS is specifically designed for environments where power quality and uptime are critical. Its 3000VA capacity and rack-mount form factor make it suitable for protecting server racks, network closets, and small data center deployments.
Typical applications include server rooms housing multiple rack-mounted servers and storage arrays, network operations centers with critical switching and routing equipment, and telecommunications installations requiring clean, uninterrupted power. The unit's ability to support mission-critical equipment, computers, data center gear, servers, and network devices makes it a versatile solution for IT infrastructure protection.
This section brings together practical product details such as Plug/Connector Type, Receptacle Type, Receptacle Detail, Load Capacity (VA), so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
Physical Profile
The SU3000RTXLCD2UN occupies 2U of rack space with dimensions of 3.40" (86.36 mm) height, 17.30" (439.42 mm) width, and 25.50" (647.70 mm) depth. Weighing approximately 70.50 lb (31978.26 g), it's designed for standard 19-inch server racks and includes rack-mounting hardware and tower support stands for flexible deployment options. The front panel features an LCD display and LED status indicators for at-a-glance monitoring.
- Width
- 17.30" (439.42 mm)
- Depth
- 25.50" (647.70 mm)
- Height
- 3.40" (86.36 mm)
- Weight
- 50 dB(A)
What's in the Box
The package includes all necessary components for installation and operation.
Highlights
- 3000VA/2700W double-conversion online UPS for mission-critical equipment protection
- 2U rack-mount form factor with included rack-mounting hardware and tower stands
- Pure sine wave output with zero transfer time for sensitive server loads
- 4.1 minutes runtime at full load, 11.3 minutes at half load
- Front panel LCD display with real-time status and configuration options
- SNMP/HTTP remote monitoring with web-based management interface
- Hot-swappable, user-replaceable battery system for maintenance without downtime
- Multiple outlet types: 1x NEMA L5-30R, 4x NEMA 5-15/20R, 4x NEMA 5-15R
- Wide input voltage range: 100-127V AC with adjustable output voltage
- 2-year limited warranty with RoHS compliance
Specifications
| Specifications | |
|---|---|
| Manufacturer | Eaton Corporation |
| Manufacturer Part Number | SU3000RTXLCD2UN |
| Brand Name | Tripp Lite series |
| Product Line | SmartOnline |
| Product Model | SU3000RTXLCD2UN |
| Product Name | SmartOnline SU3000RTXLCD2UN 3000VA Rack-mountable UPS |
| Product Type | Double Conversion Online UPS |
| Technical Information | |
| Plug/Connector Type | NEMA L5-30P |
| Receptacle Type | NEMA L5-30R,NEMA 5-15/20R,NEMA 5-15R |
| Receptacle Detail | 1 x NEMA L5-30R,4 x NEMA 5-15/20R,4 x NEMA 5-15R |
| Transfer Time | 0 ns |
| EMI/RFI Noise Filter | Yes |
| Phase | Single Phase |
| Energy Saving | Green Energy-Saving |
| Application/Usage | Mission Critical Equipment,Computer,Data Center,Server,Network Device |
| Power Description | |
| Load Capacity (VA) | 3 kVA |
| Load Capacity (Watt) | 2.70 kW |
| Input Voltage | 120 V AC |
| Input Voltage Range | 100 V AC - 127 V AC |
| Output Voltage | 100 V AC,110 V AC,115 V AC,120 V AC,127 V AC |
| Input Frequency | 60 Hz |
| Output Frequency | 60 Hz |
| Waveform Type | Pure Sine Wave |
| Surge Energy Rating | 570 J |
| Management | |
| Network Management | SNMP/HTTP Remote Monitoring |
| Alarm | Power Failure,Low Battery,Overload,UPS Fault,Remote Shutdown |
| Controls/Indicators | |
| Status Indicators | Front Panel LCD Display: UPS And Site Power Status And Operating Data Plus Configuration Of Voltage Frequency Operating Mode Alarm Function And A Variety Of Additional Options LED Indicators: 7 Front Panel LEDs Indicate Line Power Availability AC To DC Conversion Battery Mode Operation Inverter Mode ECO Mode Operation Bypass Mode Operation AC Output Status |
| Interfaces/Ports | |
| Serial Port | Yes |
| EPO Port | Yes |
| USB (HID Compliant) Port | Yes |
| Battery Information | |
| DC System Voltage | 72 V DC |
| Backup/Run Time (Full Load) | 4.10 Minute |
| Backup/Run Time (Half Load) | 11.30 Minute |
| Hot Swappable | Yes |
| Replaceable Battery | Yes |
| Environmental Conditions | |
| Maximum Operating Elevation | 9842.52 ft (3000000 mm) |
| Storage Temperature | 5°F (-15°C) - 122°F (50°C) |
| Maximum Operating Temperature | 104°F (40°C) |
| Sound Emission (A-Weighted) | 50 dB(A) |
| Thermal Dissipation | 1626 BTU/h |
| Physical Characteristics | |
| Height | 3.40" (86.36 mm) |
| Width | 17.30" (439.42 mm) |
| Depth | 25.50" (647.70 mm) |
| Rack Height | 2U |
| Form Factor | Rack-mountable |
| Weight (Approximate) | 70.50 lb (31978.26 g) |
| Miscellaneous | |
| Package Contents | 3000VA 2700W 120V Double-Conversion UPS WEBCARDLXE network management card USB cable DB9 cable Rack-mounting hardware Tower support stands Safety instructions Quick start guide |
| Country of Origin | Philippines |
| Environmentally Friendly | Yes |
| Environmental Compliance | Restriction of Hazardous Substances (RoHS) |
| Warranty | |
| Limited Warranty | 2 Year |
User Manual
FAQ
What is the power capacity of this UPS?
This Tripp Lite by Eaton SmartOnline UPS has a 3000VA (3 kVA) apparent power capacity and a 2700W (2.70 kW) real power capacity. This capacity supports substantial server and network equipment loads in rack-mounted deployments, providing sufficient power for multiple devices during outages or fluctuations.
How long will this UPS run on battery power?
At full load (2700W), the UPS provides approximately 4.1 minutes of runtime. At half load (1350W), runtime extends to approximately 11.3 minutes. These runtimes allow for orderly shutdown of connected equipment or short-term ride-through of power interruptions in data center and server room environments.
What type of outlets does this UPS have?
The unit includes multiple receptacle types: one NEMA L5-30R outlet, four NEMA 5-15/20R outlets, and four NEMA 5-15R outlets. This variety accommodates different equipment plug types commonly found in server racks and IT environments, providing flexibility for connecting servers, switches, and other network devices.
Can this UPS be mounted in a standard server rack?
Yes, this is a 2U rack-mountable UPS designed for standard 19-inch server racks. It occupies 2U of vertical space (3.40" height) and includes all necessary rack-mounting hardware. The package also includes tower support stands for freestanding deployment if rack mounting isn't required.
What remote management capabilities does this UPS offer?
The UPS supports SNMP/HTTP remote monitoring through its included WEBCARDLXE network management card. This allows IT administrators to monitor UPS status, configure settings, receive alerts for power events, and initiate remote shutdowns from any network-connected device with a web browser or SNMP management software.
Are the batteries user-replaceable in this UPS?
Yes, the battery system is both hot-swappable and user-replaceable. This design allows battery replacement without powering down connected equipment, ensuring continuous protection during maintenance. The 72V DC battery system can be serviced without specialized tools, supporting long-term UPS reliability.
What power capacity is listed for this UPS?
The listed power specification is 3 kVA, which helps position the unit for the right load level and installation role.
What voltage details are listed?
The listed power specification is 120 V AC, which helps position the unit for the right load level and installation role.