Sidebar Sidebar Sidebar

Tripp Lite SU750RTXLCD2U UPS System - 750 VA/675 W - 127 V AC, 127 V AC - 4.30 Minute Stand-by Time - 2U Tower/Rack Mountable - 6 x (SU750RTXLCD2U)

Have questions?

  • Canadian distributor

    Proud Canadian business since 2007

  • IT experts available

    Consulting & Technicial services

  • Pre-configuration services

    From VoiP phone to Clustered servers

  • Delivering across Canada

    Shipping UPS Fedex & Purolator

Free Shipping*

Write a Review
MSRP: $2,065.44
$2,065.44
$1,212.83
Save: $852.61 (41.28%)
SKU: SU750RTXLCD2U
UPC: 37332168276
Availability: Ready to ship - Stock in Canada
Weight: 1.00 LBS
Shipping: Calculated at Checkout
Adding to cart… The item has been added

    Marketing Information:

    750VA 675W 120V Battery Backup Protects Equipment against Damage, Downtime and Data Loss
    This on-line double-conversion UPS system maintains perfect output by converting AC input to DC, then reconverting UPS output to fully regulated sine wave AC. Constant on-line operation completely isolates sensitive equipment from every power problem on the AC line. The SmartOnline® SU750RTXLCD2U provides the highest level of power protection and battery backup for education, healthcare, military, government and other mission-critical IT applications where space is limited, but premium power reliability is essential.

    Reliable, Expandable Battery Backup Keeps You Operational Through Power Outages
    The field-replaceable, hot-swappable battery modules allow you to work through short power failures and give you enough time to safely save files and shut down your system in case of a prolonged blackout. Zero transfer time between on-line and battery modes maintains continuous operation of connected equipment without interruption or rebooting. Extra runtime is available by connecting up to four optional extended battery modules (BP36RT, sold separately).

    Optional LX Platform Network Management Card Allows Remote Access 24/7
    The WEBCARDLXE network interface (sold separately) enables full remote configuration and management, including load shedding, reboots of connected equipment and safe shutdowns. The IP-based Auto Probe feature ensures continuous network uptime by communicating with other network devices, detecting lost connectivity and automatically rebooting IT equipment. Optional EnviroSense2 modules (E2MT, E2MTDO and E2MTHDI, all sold separately) provide a variety of environmental monitoring and control options.

    NEMA 5-15R Outlets Protect Your Connected Components
    Eight managed 5-15R outlets provide connected equipment with pure sine wave AC output and allow you to monitor power consumption down to the outlet group level. Power provided by these outlets is filtered to protect connected equipment against damaging surges and line noise. Four outlets are grouped into two programmable load banks that let you shed non-critical loads to extend runtime for critical loads. A cooling fan helps protect equipment from overheating.

    Premium Protection from EMI/RFI Line Noise Helps Your Equipment Perform Better
    This UPS system filters out disruptive electromagnetic and radio frequency interference that can inflict hardware damage or data loss. This EMI/RFI filtering also helps your connected components perform better and last longer.

    Intuitive Front-Panel Interface for Convenient UPS Operation and Monitoring
    The two-line front-panel LCD monitoring screen features 10 selectable screens that allow quick access to a wide range of detailed UPS and site power information. LEDs show UPS status: a green light means utility power is on, an orange light means the UPS is in battery or bypass mode and a red light indicates an active alarm or fault. The control panel rotates to accommodate both rack-mount and tower configurations.

    More from the Manufacturer

    Plug/Connector Type: NEMA 5-15P

    Receptacle Type: NEMA 5-15R

    Receptacle Detail: 8 x NEMA 5-15R

    Overload Protection: Yes

    Transfer Time: 0 ns

    EMI/RFI Noise Filter: Yes

    Phase: Single Phase

    Energy Saving: High efficiency economy mode operation; Individually controllable load banks

    Application/Usage: IT Equipment,Mission Critical Equipment,Government,Healthcare,Education,Military

    Load Capacity (VA): 750 VA

    Load Capacity (Watt): 675 W

    Input Voltage: 120 V AC

    Output Voltage: 100 V AC,110 V AC,115 V AC,120 V AC,127 V AC

    Input Frequency: 60 Hz

    Output Frequency: 60 Hz

    Waveform Type: Pure Sine Wave

    Surge Energy Rating: 190 J

    Input Power Factor: 0.99

    Output Power Factor: 0.9

    Display: LCD

    Network Management: SNMP

    Alarm: Remote Shutdown,UPS StartUp,Power Failure,Overload,UPS Fault,Low Battery

    Status Indicators: 4 status-indicating LEDs

    Serial Port: Yes

    USB: Yes

    DC System Voltage: 36 V DC

    Battery Characteristics: Valve-regulated

    Battery Chemistry: Lead Acid

    Backup/Run Time (Full Load): 7.90 Minute

    Backup/Run Time (Half Load): 20.90 Minute

    Hot Swappable: Yes

    Typical Battery Recharge Time: 3 Hour

    Replaceable Battery: Yes

    Maximum Operating Elevation: 9842.52 ft (3000000 mm)

    Storage Temperature: 32°F (0°C) - 104°F (40°C)

    Operating Humidity: 0% - 96%

    Minimum Operating Temperature: 32°F (0°C)

    Maximum Operating Temperature: 104°F (40°C)

    Sound Emission: 40 dB

    Height: 3.50" (88.90 mm)

    Width: 17.50" (444.50 mm)

    Depth: 12.50" (317.50 mm)

    Rack Height: 2U

    Form Factor: Rack/Tower

    Weight (Approximate): 16.50 kg

    Package Contents:

  • SmartOnline SU750RTXLCD2U 750VA Rack/Tower UPS
  • USB cable
  • DB9 cable
  • Rack-mounting hardware
  • Tower support stands
  • Safety instructions
  • Quick start guide
  • Software Included: PowerAlert UPS Monitoring Software

    Country of Origin: China

    Environmentally Friendly: Yes

    Environmental Compliance: Registration, Evaluation, Authorization and Restriction of Chemicals (REACH),Restriction of Hazardous Substances (RoHS)

    Limited Warranty: 2 Year

    Additional Warranty Information:

    • Connected Equipment Insurance (U.S., Canada & Puerto Rico):
    • 250,000 Ultimate Lifetime Insurance

[custom-highlights]
  • Updated design for 2023
  • Offers network-grade protection against power failures and voltage fluctuations
  • Zero transfer time between on-line and battery modes for uninterrupted operation
  • Keeps equipment running during outages to allow time for file saves and safe shutdown
  • Optional WEBCARDLXE network card enables full remote access and control
  • 2-line front-panel LCD with 10 selectable screens reports detailed UPS and site power info
[/custom-highlights]

[custom-specifications]

Specifications
ManufacturerTripp Lite by Eaton
Manufacturer Part NumberSU750RTXLCD2U
Manufacturer Website Addresshttps://tripplite.eaton.com/
Brand NameTripp Lite by Eaton
Product LineSmartOnline
Product ModelSU750RTXLCD2U
Product NameSmartOnline SU750RTXLCD2U 750VA Rack/Tower UPS
Product TypeDouble Conversion Online UPS
Technical Information
Plug/Connector TypeNEMA 5-15P
Receptacle TypeNEMA 5-15R
Receptacle Detail8 x NEMA 5-15R
Overload ProtectionYes
Transfer Time0 ns
EMI/RFI Noise FilterYes
PhaseSingle Phase
Energy SavingHigh efficiency economy mode operation; Individually controllable load banks
Application/UsageIT Equipment,Mission Critical Equipment,Government,Healthcare,Education,Military
Power Description
Load Capacity (VA)750 VA
Load Capacity (Watt)675 W
Input Voltage120 V AC
Output Voltage100 V AC,110 V AC,115 V AC,120 V AC,127 V AC
Input Frequency60 Hz
Output Frequency60 Hz
Waveform TypePure Sine Wave
Surge Energy Rating190 J
Input Power Factor0.99
Output Power Factor0.9
Display & Graphics
DisplayLCD
Management
Network ManagementSNMP
AlarmRemote Shutdown,UPS StartUp,Power Failure,Overload,UPS Fault,Low Battery
Controls/Indicators
Status Indicators4 status-indicating LEDs
Interfaces/Ports
Serial PortYes
USBYes
Battery Information
DC System Voltage36 V DC
Battery CharacteristicsValve-regulated
Battery ChemistryLead Acid
Backup/Run Time (Full Load)7.90 Minute
Backup/Run Time (Half Load)20.90 Minute
Hot SwappableYes
Typical Battery Recharge Time3 Hour
Replaceable BatteryYes
Environmental Conditions
Maximum Operating Elevation9842.52 ft (3000000 mm)
Storage Temperature32°F (0°C) - 104°F (40°C)
Operating Humidity0% - 96%
Minimum Operating Temperature32°F (0°C)
Maximum Operating Temperature104°F (40°C)
Sound Emission40 dB
Physical Characteristics
Height3.50" (88.90 mm)
Width17.50" (444.50 mm)
Depth12.50" (317.50 mm)
Rack Height2U
Form FactorRack/Tower
Weight (Approximate)16.50 kg
Miscellaneous
Package Contents
  • SmartOnline SU750RTXLCD2U 750VA Rack/Tower UPS
  • USB cable
  • DB9 cable
  • Rack-mounting hardware
  • Tower support stands
  • Safety instructions
  • Quick start guide
  • Software IncludedPowerAlert UPS Monitoring Software
    Country of OriginChina
    Environmentally FriendlyYes
    Environmental ComplianceRegistration, Evaluation, Authorization and Restriction of Chemicals (REACH),Restriction of Hazardous Substances (RoHS)
    Warranty
    Limited Warranty2 Year
    Additional Warranty Information
    • Connected Equipment Insurance (U.S., Canada & Puerto Rico):
    • 250,000 Ultimate Lifetime Insurance

    [/custom-specifications]

    [custom-options]

     

     

     

     

     

    [/custom-options]

    [custom-user-manual]

    Available Documentation:


    User-Manual
    Manufacturer-Brochure

    [/custom-user-manual]

    Warranty Infomartion

    2 Year

    Customers also viewed