Liebert PD5-201 8-Outlet PDU with UPS Maintenance Bypass for GXT5 5-6kVA HV Models - Hardwired Input - 2x IEC C19 & 6x IEC C13
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Product Overview
The Liebert PD5-201 is an 8-outlet power distribution unit designed specifically for Vertiv Liebert GXT5 5-6kVA HV UPS systems. This PDU integrates UPS maintenance bypass functionality, allowing critical equipment to remain powered during UPS servicing, repairs, or replacement without interruption.
Featuring a hardwired input connection and eight IEC outlets, this unit provides reliable power distribution while maintaining the integrity of your UPS-protected infrastructure. The PD5-201 serves as a dedicated accessory that enhances the operational flexibility and uptime of compatible Liebert UPS installations.
This section brings together practical product details such as Plug/Connector Type, Receptacle Detail, Country of Origin, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
Technical Overview
This power distribution accessory delivers eight IEC 60320 outlets configured with two C19 and six C13 receptacles. The hardwired input connection ensures secure power delivery from the UPS system, while the outlet mix supports both high-power and standard equipment connections commonly found in IT environments.
Designed exclusively for Vertiv Liebert GXT5 5-6kVA HV models operating at 208V, the PD5-201 maintains electrical compatibility and safety standards. The unit enables maintenance bypass operations through simple plug-and-play connectivity, keeping attached devices online during UPS service windows.
This section brings together practical product details such as Plug/Connector Type, Receptacle Detail, Country of Origin, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
Key Product Advantages
The PD5-201 eliminates unnecessary downtime by providing continuous power to connected equipment during UPS maintenance procedures. This capability is essential for environments where uptime is critical and scheduled maintenance cannot disrupt operations.
Maintenance Bypass Functionality
Enables UPS servicing, repair, or replacement without powering down connected devices, maintaining business continuity during maintenance windows.
- Avoids service interruptions
- Simplifies maintenance scheduling
- Preserves UPS protection during bypass
Optimized Outlet Configuration
The 2 C19 and 6 C13 outlet mix accommodates both high-power servers and standard IT equipment, providing flexible power distribution for diverse device loads.
- Supports mixed equipment types
- Matches common power requirements
- Reduces need for additional adapters
Plug-and-Play Integration
Simple connection to compatible Liebert UPS systems ensures quick deployment and reliable operation without complex configuration or installation procedures.
- Minimizes setup time
- Reduces installation errors
- Ensures compatibility with GXT5 HV models
Deployment / Use Cases
The Liebert PD5-201 is ideal for data centers, server rooms, and network closets where Vertiv Liebert GXT5 5-6kVA HV UPS systems protect critical infrastructure. It enables scheduled maintenance, UPS upgrades, or emergency repairs without disrupting the power supply to servers, storage, networking gear, or other essential equipment.
This PDU is particularly valuable in environments with strict uptime requirements, such as healthcare facilities, financial institutions, and enterprise IT operations. The maintenance bypass capability allows IT teams to perform necessary UPS servicing during business hours without risking downtime, simplifying maintenance planning and reducing operational risk.
Data Center Maintenance
Facilitates UPS servicing in server environments where continuous operation is mandatory, allowing maintenance during regular hours without service interruption.
UPS Replacement Projects
Enables smooth transition during UPS upgrades by keeping equipment powered while old units are removed and new systems are installed.
Highlights
- Power distribution unit with integrated UPS maintenance bypass functionality
- Compatible with Vertiv Liebert GXT5 5-6kVA HV (208V) UPS models
- Eight IEC outlets: two C19 and six C13 receptacles
- Hardwired input connection for secure power delivery
- Enables continuous operation during UPS maintenance, repair, or replacement
- Plug-and-play installation with compatible Liebert UPS systems
- Eliminates unnecessary downtime for connected equipment
- Maintains power to critical devices during UPS service windows
Specifications
| Specifications | |
|---|---|
| Manufacturer | Vertiv |
| Manufacturer Part Number | PD5-201 |
| Brand Name | Vertiv Liebert |
| Product Name | 8-Outlets PDU |
| Packaged Quantity | 1 |
| Product Type | PDU |
| Technical Information | |
| Plug/Connector Type | Hardwired |
| Receptacle Detail | 2 x IEC 60320 C19,6 x IEC 60320 C13 |
| Miscellaneous | |
| Country of Origin | China |
FAQ
What UPS models is the PD5-201 compatible with?
The Liebert PD5-201 is specifically designed for Vertiv Liebert GXT5 5-6kVA HV UPS models operating at 208V. It provides maintenance bypass functionality and power distribution exclusively for these compatible UPS systems, ensuring electrical compatibility and safe operation.
How many outlets does this PDU have and what types?
This power distribution unit features eight IEC 60320 outlets configured with two C19 receptacles and six C13 receptacles. The C19 outlets support higher-power equipment, while the C13 outlets accommodate standard IT devices, providing flexible power distribution for mixed equipment environments.
What is the input connection type for the PD5-201?
The PD5-201 utilizes a hardwired input connection rather than a plug-type connector. This hardwired design ensures secure, reliable power delivery from the compatible UPS system and is typical for PDUs integrated with UPS maintenance bypass functionality in professional installations.
How does the maintenance bypass functionality work?
The maintenance bypass feature allows the UPS to be taken offline for servicing, repair, or replacement while connected equipment continues to receive power directly from the utility source. This is achieved through the PDU's design, which enables a seamless transition that maintains power to critical devices without interruption during maintenance procedures.
What are the primary benefits of using this PDU?
The PD5-201 eliminates unnecessary downtime by enabling UPS maintenance without powering down connected equipment. It provides reliable power distribution through eight IEC outlets while offering plug-and-play integration with compatible Liebert UPS systems. This combination ensures business continuity during maintenance windows and simplifies power management for critical infrastructure.
Is this PDU suitable for rack-mounted installations?
While specific mounting details aren't provided in the specifications, the PD5-201 is designed as an accessory for Vertiv Liebert GXT5 UPS systems, which are typically deployed in rack or tower configurations. The hardwired input and maintenance bypass functionality make it suitable for professional IT environments where UPS systems are installed in racks or dedicated equipment areas.