APC by Schneider Electric GVSUPS80KMHS Galaxy VS 80kVA Tower UPS - Three-Phase Double Conversion Online - 80 kW - 415/400/380 V AC Input - 400 V AC

SKU: GVSUPS80KMHS
UPC: 731304418382
(No reviews) Write a Review
MSRP: $69,137.32
$69,137.32
$47,850.99
Save: $21,286.33 (30.79%)
Warranty Information: Covered by Manufacturer
Condition: New
Width: 52.10 (cm)
Height: 148.50 (cm)
Depth: 84.70 (cm)

Ask for ETA! 🗨️

Logo cards
B2B Pricing

Business volume discounts

IT Experts

Technical guidance

IT Configuration

Preparation & staging

Canada Stock

QC · ON · AB · BC

Product Features

Description

Product Overview

The APC by Schneider Electric Galaxy VS 80kVA Tower UPS is a high-capacity three-phase double conversion online uninterruptible power supply designed for demanding commercial, industrial, and data center environments. It provides 80 kVA (80 kW) of reliable power protection, ensuring critical systems remain operational during utility power disturbances, outages, or fluctuations.

This Galaxy VS model features a versatile multi-voltage input accepting 415 V AC, 400 V AC, or 380 V AC, with a wide input range from 340 V AC to 460 V AC, and delivers a stable 400 V AC sine wave output. The unit incorporates an LCD display for clear status monitoring and system management, housed in a robust white tower enclosure suitable for floor installation.

This section brings together practical product details such as Phase, Application/Usage, Load Capacity (VA), Load Capacity (Watt), so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.

Power
80 kVA
Power Capacity
415 V AC,400 V AC,380 V ACTower
Power Capacity & Topology
Load Capacity80 kVA / 80 kW
PhaseThree Phase
Input & Output Electrical
Input Voltage415 V AC, 400 V AC, 380 V AC
Input Voltage Range340 V AC - 460 V AC
Output Voltage400 V AC
Battery & System
DC System Voltage576 V DC
Battery ChemistryLithium Ion (Li-Ion)
Battery CharacteristicsValve Regulated Lead Acid (VRLA)
Physical & Environmental
Form FactorTower
Product ColorWhite
Maximum Operating Temperature104°F (40°C)

Technical Overview

Engineered with double conversion online topology, the UPS continuously conditions incoming power, providing isolation from grid anomalies and delivering clean, regulated sine wave output. The electrical specifications include an input frequency of 70 Hz and output frequency of 60 Hz, with an input power factor of 0.7. The system operates on a 576 V DC bus and manages thermal dissipation of 8394 BTU/h.

Battery support includes Valve Regulated Lead Acid (VRLA) characteristics with Lithium Ion (Li-Ion) chemistry. Environmental resilience is confirmed with operation up to 104°F (40°C), storage humidity tolerance from 10% to 80%, and a maximum operating elevation of 3000 ft (914400 mm). Sound emission is rated at 68 dB(A) during typical operation.

Load Capacity (VA)80 kVA
Load Capacity (Watt)80 kW
Input Frequency70 Hz
Output Frequency60 Hz
Input Power Factor0.7
Thermal Dissipation8394 BTU/h
Double Conversion OnlineSine Wave OutputLCD DisplayAlarmThree Phase

Key Product Advantages

The Galaxy VS 80kVA Tower UPS combines substantial power capacity with advanced electrical conditioning, making it a cornerstone for uptime-critical deployments. Its multi-voltage input flexibility accommodates various regional power grids, while the double conversion technology ensures output purity regardless of input quality.

High-Capacity Power Protection

Delivers 80 kVA/80 kW of reliable backup power, suitable for protecting large server racks, industrial machinery, or critical data center infrastructure from power interruptions.

  • Three-phase double conversion online topology
  • Stable 400 V AC sine wave output
  • Wide input voltage range (340-460 V AC)

Robust Design for Demanding Environments

Built for industrial and data center applications with a durable tower form factor, high-temperature operation up to 40°C, and comprehensive alarm system for proactive monitoring.

  • White tower enclosure for floor placement
  • Operates up to 104°F (40°C)
  • Integrated alarm for fault notification

Deployment / Use Cases

This UPS is specified for data center, critical system, commercial, and industrial applications. Its 80 kVA capacity suits it for protecting consolidated high-density loads or distributed critical circuits within a facility.

Deployment scenarios include backing up entire server racks, supporting industrial automation controllers, or providing clean power to sensitive laboratory or medical equipment. The tower form factor offers flexibility for placement in equipment rooms or on raised floors without dedicated rack space.

Data Center & Critical Systems

Ideal for server rooms, network closets, or data centers requiring high-availability power for racks of IT equipment, storage arrays, and networking gear.

  • Protects against power sags, surges, and outages
  • Ensures continuous operation of critical servers
  • Sine wave output compatible with sensitive electronics

Industrial & Commercial Facilities

Supports manufacturing equipment, control systems, medical devices, or telecommunications infrastructure where power consistency is non-negotiable.

  • Handles industrial three-phase power loads
  • Tolerant of harsh electrical environments
  • LCD provides at-a-glance system health

Physical Profile

The UPS is housed in a white tower enclosure measuring 58.46" (1485 mm) in height, 20.51" (521 mm) in width, and 33.35" (847 mm) in depth, with an approximate weight of 290 kg. This substantial footprint is designed for stable floor-standing installation, often in dedicated electrical or server rooms. The form factor prioritizes serviceability and heat dissipation, with dimensions that accommodate internal battery banks and power electronics while allowing adequate clearance for airflow and maintenance access.

Color
White
Dimensions
Width
20.51" (521 mm)
Depth
33.35" (847 mm)
Height
58.46" (1485 mm)
Weight
68 dB(A)
[custom-highlights]

Highlights

  • 80 kVA / 80 kW three-phase double conversion online UPS
  • Accepts 415 V AC, 400 V AC, or 380 V AC input with 340-460 V AC range
  • Delivers 400 V AC pure sine wave output
  • LCD display for system monitoring and configuration
  • White tower form factor for floor installation
  • Operates up to 104°F (40°C) maximum temperature
  • 576 V DC system voltage with Li-Ion battery chemistry
  • Includes alarm for audible and visual fault indication
  • Thermal dissipation of 8394 BTU/h
  • Suitable for data center, critical system, commercial, and industrial use
[/custom-highlights][custom-specifications]

Specifications

Specifications
ManufacturerSchneider Electric SA
Manufacturer Part NumberGVSUPS80KMHS
Brand NameAPC by Schneider Electric
Product LineGalaxy VS
Product NameGalaxy VS 80kVA Tower UPS
Packaged Quantity1 Pack
Product TypeDouble Conversion Online UPS
Technical Information
PhaseThree Phase
Application/UsageData Center,Critical System,Commercial,Industrial
Power Description
Load Capacity (VA)80 kVA
Load Capacity (Watt)80 kW
Input Voltage415 V AC,400 V AC,380 V AC
Input Voltage Range340 V AC - 460 V AC
Output Voltage400 V AC
Input Frequency70 Hz
Output Frequency60 Hz
Waveform TypeSine Wave
Input Power Factor0.7
Display & Graphics
DisplayLCD
Management
AlarmYes
Battery Information
DC System Voltage576 V DC
Battery CharacteristicsValve Regulated Lead Acid (VRLA)
Battery ChemistryLithium Ion (Li-Ion)
Battery Energy0 J
Environmental Conditions
Maximum Operating Temperature104°F (40°C)
Maximum Operating Elevation3000 ft (914400 mm)
Storage Relative Humidity10% - 80%
Sound Emission (A-Weighted)68 dB(A)
Thermal Dissipation8394 BTU/h
Physical Characteristics
Product ColorWhite
Form FactorTower
Height58.46" (1485 mm)
Width20.51" (521 mm)
Depth33.35" (847 mm)
Weight (Approximate)290 kg
[/custom-specifications][custom-user-manual]

User Manual

This section contains official documentation provided by the manufacturer, including product manuals, brochures, and supplementary materials.
[/custom-user-manual][custom-faq]

FAQ

What is the power capacity of this APC Galaxy VS UPS?

This UPS provides 80 kVA (kilovolt-amperes) of apparent power and 80 kW (kilowatts) of real power capacity. It is designed to support substantial three-phase electrical loads typical in data centers, industrial equipment, or large server installations, offering robust backup power during utility failures or disturbances.

What input voltages does this UPS support?

The unit accepts three-phase input at 415 V AC, 400 V AC, or 380 V AC. It has a wide input voltage range from 340 V AC to 460 V AC, providing flexibility for different regional power grids or sites with variable utility voltage, ensuring reliable operation even under less-than-ideal input conditions.

What type of output does this UPS provide?

It delivers a 400 V AC pure sine wave output. Sine wave output is essential for compatibility with sensitive electronic equipment, including servers, networking gear, and industrial controls, as it mimics utility power quality and prevents potential damage or malfunction caused by distorted waveforms.

What is the form factor and color of this UPS?

This UPS features a tower form factor in white. The tower design is intended for floor-standing installation, making it suitable for equipment rooms or data centers where rack mounting is not required or where additional battery capacity is housed within the unit's footprint.

What battery technology is used in this UPS?

The system utilizes Lithium Ion (Li-Ion) battery chemistry with Valve Regulated Lead Acid (VRLA) characteristics. It operates on a 576 V DC system voltage. Li-Ion batteries often offer advantages in energy density, lifecycle, and maintenance compared to traditional lead-acid, supporting reliable backup performance.

What are the key environmental operating specifications?

The UPS can operate at temperatures up to 104°F (40°C) and elevations up to 3000 ft (914400 mm). It has a storage humidity range of 10% to 80% and emits sound at 68 dB(A) during operation. These specs ensure reliability in varied climatic conditions and help plan installation locations.

What power capacity is listed for this UPS?

The listed power specification is 80 kVA, which helps position the unit for the right load level and installation role.

What voltage details are listed?

The listed power specification is 415 V AC,400 V AC,380 V AC, which helps position the unit for the right load level and installation role.

[/custom-faq]
Volume Discounts
Qty Price Available
Match Price Request

Found a lower price? Send us the link and we will do our best to match or beat it.

Request received. We will reply within 24 hours.
Fleet Network
Wholesale & B2B
Partner with Us

Looking to buy in bulk? We offer competitive pricing, dedicated support, and custom solutions for businesses of all sizes.

Volume Discounts

Tiered pricing structure designed to maximize your margins as you grow.

Dedicated Account Manager

Direct access to a specialist who understands your business needs.

Fast & Reliable Shipping

Priority processing and discounted shipping rates for bulk orders.

Request a Quote
Thank you!
Your request has been sent successfully.
APC by Schneider Electric GVSUPS80KMHS Galaxy VS 80kVA Tower UPS - Three-Phase Double Conversion Online - 80 kW - 415/400/380 V AC Input - 400 V AC
MSRP: $69,137.32
$69,137.32
$47,850.99
Save: $21,286.33 (30.79%)
Out of stock