Sidebar Sidebar Sidebar

Shipping included*

APC by Schneider Electric APDU10350MO NetShelter Rack PDU Advanced - Metered Outlet - 3PH - 17. 3kW/17. 3kVA - 48 Outlets - IEC 60309 30A - 0U Rack

SKU: APDU10350MO
UPC: 731304439738
(No reviews) Write a Review
MSRP: $5,367.99
$5,367.99
$4,786.99
Save: $581.00 (10.82%)
Warranty Information: 3 Year
Condition: New
Width: 5.60 (cm)
Height: 1.23 (cm)
Depth: 7.50 (cm)

Ask for ETA! 🗨️

Logo cards
B2B Pricing

Business volume discounts

IT Experts

Technical guidance

IT Configuration

Preparation & staging

Canada Stock

QC · ON · AB · BC

Product Features

Description

Product Overview

The APC by Schneider Electric NetShelter Advanced Metered Rack PDU (APDU10350MO) delivers professional-grade three-phase power distribution for demanding data center and server room environments. This metered PDU provides real-time power monitoring through an interactive LCD display while distributing 17.3kW/17.3kVA across 48 strategically configured outlets.

Engineered for vertical side-mount installation in standard 19-inch racks, this 0U form factor unit maximizes rack space efficiency while offering comprehensive network management capabilities. The black finish and compact 2.20" width ensure seamless integration into existing infrastructure without disrupting airflow or accessibility.

This section brings together practical product details such as PDU Type, Phase, Plug/Connector Type, Input Voltage, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.

In practical terms, this overview should help a buyer understand what the product is, the type of environment it suits, and the core reasons it may be chosen over a more generic alternative. That context is especially useful for business purchasing, where fit, consistency, and ease of use usually matter as much as individual specifications.

Power
17.30 kVA
Power Capacity
415 V,480 VRack
Power Capacity & Input
Power Rating17.30 kW / 17.30 kVA
Input Voltage415 V, 480 V
Input Current30 A
Output & Configuration
Outlet Count48 outlets
Receptacle Types24 x IEC 60320 C13/C15/C19/C21, 24 x IEC 60320 C13/C15
Output Voltage240 V AC
Physical & Installation
Form FactorRack, 0U height
MountingVertical side placement
Cord Length5.9 ft (1.80 m)

Technical Overview

This three-phase PDU accepts input voltages of 415V or 480V with a robust 30A current rating, delivering stable 240V AC output across all 48 outlets. The metered design provides active power measurements including volts, amps, kW, and kWh through both the local LCD display and remote network management via the integrated RJ-45 port.

The outlet configuration combines 24 IEC 60320 C13/C15/C19/C21 receptacles with 24 additional C13/C15 receptacles, offering flexibility for mixed IT equipment loads. Input voltage ranges support operation from 200-240V AC and 346-415V AC, ensuring compatibility with various power infrastructures.

This section brings together practical product details such as PDU Type, Phase, Plug/Connector Type, Input Voltage, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.

Power Capacity17.30 kW / 17.30 kVA
Input ConfigurationIEC 60309 30A 3P+N+PE
Outlet Mix48 total (24 C13/C15/C19/C21 + 24 C13/C15)
Three PhaseNetwork ManagementActive Monitoring0U Rack Mount

Key Product Advantages

The 0U vertical side-mount design preserves valuable rack space for equipment while providing full three-phase power distribution. Network management capabilities enable remote monitoring and control, supporting proactive power management and capacity planning in critical IT environments.

Comprehensive Power Monitoring

The interactive LCD display provides real-time visibility into power consumption metrics including voltage, current, kilowatts, and kilowatt-hours at both the phase and unit level.

  • Local display for instant status
  • Network-enabled remote monitoring
  • Phase-level measurement granularity

High-Density Outlet Configuration

With 48 strategically arranged outlets, this PDU maximizes power distribution capacity while maintaining proper spacing for power cord management and airflow.

  • Mixed receptacle types for flexibility
  • Optimized for server rack density
  • Reduces need for additional PDUs

Deployment / Use Cases

This metered rack PDU serves critical applications where power monitoring, high outlet density, and three-phase distribution are essential. The vertical side-mount installation makes it particularly suitable for racks with limited front-to-back space or those requiring clean cable management along rack sides.

IT managers deploy this unit when they need to monitor power consumption at the rack level for capacity planning, chargeback accounting, or identifying underutilized equipment. The network management interface integrates with existing data center infrastructure management (DCIM) systems for centralized monitoring.

Data Center Power Distribution

Ideal for distributing three-phase power to high-density server racks, network cabinets, and storage arrays in enterprise data centers and colocation facilities.

Server Room Infrastructure

Provides monitored power distribution for server clusters, blade enclosures, and networking equipment in medium to large server rooms requiring three-phase input.

Physical Profile

The PDU features a slim 2.20" (56 mm) width and 2.95" (75 mm) depth profile that mounts vertically along rack sides without consuming equipment U space. At 70.08" (1780 mm) height, it accommodates full-height rack installations while the 5.9 ft (1.80 m) input cord provides flexible connection to power sources.

Weighing approximately 21.16 lb (9598 g), the unit maintains a manageable weight for installation while the all-black finish ensures professional appearance in visible rack environments. The vertical orientation and side placement optimize rack airflow and cable routing compared to horizontal PDUs.

Color
Black
Dimensions
Width
2.20" (56 mm)
Depth
2.95" (75 mm)
Height
0U
Weight
21.16 lb (9598.01 g)
Length
5.9 ft (1.80 m)
[custom-highlights]

Highlights

  • 17.3 kW / 17.3 kVA three-phase power capacity
  • 48 total outlets with mixed IEC 60320 receptacle types
  • Interactive LCD display for real-time power monitoring
  • Network management via RJ-45 for remote monitoring
  • 0U vertical side-mount rack form factor
  • IEC 60309 30A 3P+N+PE input connector
  • 415V/480V input voltage with 240V output
  • Three-year APC warranty with RoHS compliance
[/custom-highlights][custom-specifications]

Specifications

Specifications
ManufacturerSchneider Electric SA
Manufacturer Part NumberAPDU10350MO
Brand NameAPC by Schneider Electric
Product LineNetShelter
Product NameNetShelter 48-Outlets PDU
Product TypePDU
Technical Information
PDU TypeMetered
PhaseThree Phase
Plug/Connector TypeIEC 60309 30A 3P+N+PE
Receptacle TypeIEC 60320 C13/C15/C19/C21,IEC 60320 C13/C15
Receptacle Detail24 x IEC 60320 C13/C15/C19/C21,24 x IEC 60320 C13/C15
Power Description
Input Voltage415 V,480 V
Input Voltage Range200 V AC - 240 V AC,346 V AC - 415 V AC
Output Voltage240 V AC
Power Rating (VA)17.30 kVA
Power Rating (Watt)17.30 kW
Input Current30 A
Interfaces/Ports
Network (RJ-45)Yes
Physical Characteristics
Color FamilyBlack
Product ColorBlack
Mounting OrientationVertical
Form FactorRack
PlacementSide
Rack Height0U
Cord Length5.9 ft (1.80 m)
Height70.08" (1780 mm)
Width2.20" (56 mm)
Depth2.95" (75 mm)
Weight (Approximate)21.16 lb (9598.01 g)
Miscellaneous
Country of OriginIndia
Environmentally FriendlyYes
Environmental ComplianceRestriction of Hazardous Substances (RoHS)
Warranty
Limited Warranty3 Year
[/custom-specifications][custom-user-manual]

User Manual

This section contains official documentation provided by the manufacturer, including product manuals, brochures, and supplementary materials.
[/custom-user-manual][custom-faq]

FAQ

What power capacity does this rack PDU provide?

This APC NetShelter PDU delivers 17.30 kilowatts (17.30 kW) and 17.30 kilovolt-amperes (17.30 kVA) of three-phase power capacity. It supports input voltages of 415V or 480V with a 30A current rating, distributing 240V AC output across all 48 outlets for high-density server rack applications.

How many outlets does this PDU have and what types?

The PDU features 48 total outlets configured as 24 IEC 60320 C13/C15/C19/C21 receptacles and 24 additional IEC 60320 C13/C15 receptacles. This mixed configuration accommodates various IT equipment power cords, from standard server C13 connections to devices requiring C19 or C21 connectors for higher power draw.

What monitoring capabilities does the metered design provide?

The advanced metered PDU includes an interactive LCD display that shows real-time power measurements including voltage, current, kilowatts, and kilowatt-hours. Network connectivity via RJ-45 enables remote monitoring and management, allowing IT staff to track power consumption at both the unit and phase level for capacity planning and efficiency analysis.

How is this PDU installed in a server rack?

This PDU uses a 0U vertical side-mount form factor that installs along the sides of standard 19-inch racks without consuming equipment U space. The vertical orientation and side placement optimize rack airflow and cable management while the slim 2.20" width ensures minimal intrusion into the rack's usable depth for equipment installation.

What input connector and voltage does this PDU require?

The PDU uses an IEC 60309 30A 3P+N+PE (three-phase plus neutral plus protective earth) input connector. It accepts input voltages of 415V or 480V with operational ranges of 200-240V AC and 346-415V AC, delivering stable 240V AC output to all connected equipment through its 48 outlets.

What warranty and compliance certifications apply to this unit?

APC provides a three-year limited warranty for this NetShelter PDU. The unit is RoHS (Restriction of Hazardous Substances) compliant and manufactured in India with environmentally friendly materials. The black finish and professional construction ensure durability in data center environments with continuous operation requirements.

What power capacity is listed for this UPS?

The listed power specification is 17.30 kVA, which helps position the unit for the right load level and installation role.

What voltage details are listed?

The listed power specification is 415 V,480 V, which helps position the unit for the right load level and installation role.

[/custom-faq]
Volume Discounts
Qty Price Available
Match Price Request

Found a lower price? Send us the link and we will do our best to match or beat it.

Request received. We will reply within 24 hours.
Fleet Network
Wholesale & B2B
Partner with Us

Looking to buy in bulk? We offer competitive pricing, dedicated support, and custom solutions for businesses of all sizes.

Volume Discounts

Tiered pricing structure designed to maximize your margins as you grow.

Dedicated Account Manager

Direct access to a specialist who understands your business needs.

Fast & Reliable Shipping

Priority processing and discounted shipping rates for bulk orders.

Request a Quote
Thank you!
Your request has been sent successfully.
APC by Schneider Electric APDU10350MO NetShelter Rack PDU Advanced - Metered Outlet - 3PH - 17. 3kW/17. 3kVA - 48 Outlets - IEC 60309 30A - 0U Rack
MSRP: $5,367.99
$5,367.99
$4,786.99
Save: $581.00 (10.82%)
Out of stock