Shipping included*
Exclusions
Additional shipping fees may apply in rare circumstances for deliveries outside standard service areas. In most cases, this only potentially affects shipments to the Northwest Territories and Yukon, as well as certain heavy or oversized items.
APC by Schneider Electric APDU9967 NetShelter 9000 Switched Rack PDU - 17. 3kW/17. 3kVA - 208V - 48 Outlets - 42 C13/C15 - 6 C19/C21 - 0U Vertical Tower
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This PDU is engineered for three-phase 208V AC power distribution, with input and output voltages matched for direct compatibility. It uses an IEC 60309 60A 3P+PE plug for connection to a compatible power source. The electrical design ensures stable power delivery across all 48 outlets, which are divided into 42 IEC 60320 C13/C15 outlets for standard server and network gear and 6 IEC 60320 C19/C21 outlets for high-power devices.
Network management is facilitated through a built-in RJ-45 port, supporting SNMP for integration into existing data center infrastructure management (DCIM) systems. This allows for monitoring of aggregate current draw, outlet-level status, and remote power cycling. The unit includes a 6-foot (1.82 m) input power cord for flexible installation.
This section brings together practical product details such as PDU Type, Phase, Plug/Connector Type, Input Voltage, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
Key Product Advantages
High-Density Power Distribution
With 17.3kW capacity and 48 outlets, this PDU consolidates power distribution for an entire rack of equipment, reducing clutter and simplifying power infrastructure.
- Supports high-power compute and storage loads
- Eliminates the need for multiple smaller PDUs
Intelligent Remote Management
The switched functionality and SNMP interface provide granular control and visibility over connected devices, enabling proactive power management and reducing downtime.
- Individual outlet on/off/reboot control
- Real-time current monitoring per outlet group
Space-Optimized Rack Design
The 0U vertical tower mounting occupies no rack unit space, preserving full rack height for servers and switches while organizing power cables along the rack side.
- Frees up valuable U-space for revenue-generating gear
- Promotes cleaner cable management and airflow
Deployment / Use Cases
This switched rack PDU is ideal for centralized power distribution in high-density data center racks, server rooms, and network closets where reliable, manageable power is critical. It is commonly deployed to support racks filled with blade servers, high-performance computing nodes, large storage systems, and top-of-rack networking switches that require substantial, monitored power.
Typical use cases include enterprise data centers needing per-outlet control for remote hands management, colocation facilities where customers require independent outlet rebooting, and IT environments implementing energy efficiency initiatives through detailed power monitoring. The mix of C13 and C19 outlets ensures compatibility with both standard and high-power equipment, making it a versatile solution for heterogeneous racks.
Physical Profile
The PDU features a vertical tower form factor designed for side-mounting in a standard 19-inch equipment rack. Its dimensions are 72.17 inches (1833 mm) in height, 4.37 inches (111 mm) in width, and 2.99 inches (76 mm) in depth, with a weight of approximately 32.06 lb (14.54 kg). The 0U rack height designation means it mounts vertically on the rack frame without consuming any rack units, maximizing usable space. The vertical orientation and slim profile facilitate organized cable routing and maintain optimal airflow within the rack enclosure.
- Width
- 4.37" (111 mm)
- Depth
- 2.99" (76 mm)
- Height
- 0U
- Weight
- 32.06 lb (14542.17 g)
- Length
- 6 ft (1.82 m)
What's in the Box
The package includes all necessary components for installation and operation.
Highlights
- 17.3 kW / 17.3 kVA high-power capacity for demanding rack loads
- 48 total outlets: 42 IEC C13/C15 and 6 IEC C19/C21 for broad compatibility
- Switched PDU with SNMP management for remote monitoring and control
- 0U vertical tower design saves rack space and improves cable management
- Three-phase 208V input and output for data center power standards
- Vertical side-mount installation with included rack brackets
- Includes a 6-foot (1.82 m) input power cord
- RoHS compliant and environmentally friendly
- Backed by a 3-year limited warranty
- Manufactured in India
Specifications
| Specifications | |
|---|---|
| Manufacturer | Schneider Electric SA |
| Manufacturer Part Number | APDU9967 |
| Brand Name | APC by Schneider Electric |
| Product Series | 9000 |
| Product Name | NetShelter 9000 48-Outlets PDU |
| Product Type | PDU |
| Technical Information | |
| PDU Type | Switched |
| Phase | Three Phase |
| Plug/Connector Type | IEC 60309 60A 3P+PE |
| Receptacle Type | IEC 60320 C19/C21,IEC 60320 C13/C15 |
| Receptacle Detail | 6 x IEC 60320 C19/C21,42 x IEC 60320 C13/C15 |
| Power Description | |
| Input Voltage | 208 V |
| Output Voltage | 208 V AC |
| Power Rating (VA) | 17.30 kVA |
| Power Rating (Watt) | 17.30 kW |
| Input Current | 48 A |
| Management | |
| Management | SNMP gallineta nórdica |
| Interfaces/Ports | |
| Network (RJ-45) | Yes |
| Physical Characteristics | |
| Mounting Orientation | Vertical |
| Mount Type | Rack-mountable |
| Form Factor | Tower |
| Placement | Side |
| Rack Height | 0U |
| Cord Length | 6 ft (1.82 m) |
| Height | 72.17" (1833 mm) |
| Width | 4.37" (111 mm) |
| Depth | 2.99" (76 mm) |
| Weight (Approximate) | 32.06 lb (14542.17 g) |
| Miscellaneous | |
| Package Contents | NetShelter 9000 48-Outlets PDU Installation guide Rack mounting brackets Safety guide Serial configuration cable |
| Country of Origin | India |
| Environmentally Friendly | Yes |
| Environmental Compliance | Restriction of Hazardous Substances (RoHS) |
| Warranty | |
| Limited Warranty | 3 Year |
User Manual
FAQ
What is the power capacity of this APC rack PDU?
This APC NetShelter 9000 PDU has a power rating of 17.30 kilowatts (kW) and 17.30 kilovolt-amperes (kVA). This high capacity is designed to support the cumulative power draw of multiple servers, storage systems, and networking equipment within a single rack in a data center environment.
How many outlets does this PDU have and what types are they?
The PDU provides a total of 48 IEC power outlets. This includes 42 outlets of the IEC 60320 C13/C15 type, commonly used for servers and network devices, and 6 outlets of the IEC 60320 C19/C21 type, which are designed for higher-power equipment. This mix accommodates a wide range of IT hardware power cords.
What does '0U' and 'vertical tower' mean for rack mounting?
'0U' means this PDU does not consume any vertical rack units (U) of space within the rack's front or rear mounting rails. Instead, it is a 'vertical tower' designed to be mounted on the side posts of a standard 19-inch rack. This side-mount design preserves all available U-space for servers, switches, and other active equipment while keeping power distribution organized.
What management capabilities does this switched PDU offer?
As a switched PDU, it offers individual outlet-level control and monitoring. Through its SNMP management interface (accessible via the RJ-45 network port), you can remotely power individual outlets on/off, reboot connected devices, and monitor real-time current draw. This enables precise power management, remote troubleshooting, and energy usage tracking without physical access to the rack.
What is the input voltage and plug type for this unit?
The PDU requires a three-phase 208-volt AC power source. It comes with an IEC 60309 60A 3P+PE (three-phase plus protective earth) input plug. This is a common connector type for high-capacity power distribution in North American data centers. The output voltage to the equipment outlets is also 208V AC.
What is included in the box with the PDU?
The package contains the NetShelter 9000 48-Outlets PDU unit itself, an installation guide, the necessary rack mounting brackets for side installation, a safety guide, and a serial configuration cable for initial setup of the management interface. All components required for standard mounting and operation are provided.
What power capacity is listed for this UPS?
The listed power specification is 17.30 kVA, which helps position the unit for the right load level and installation role.
What voltage details are listed?
The listed power specification is 208 V, which helps position the unit for the right load level and installation role.