CyberPower PDU30BT10F10R Basic PDU - 20 Outlets (10 Front/10 Rear) - 120V AC - 30A - 1U Vertical Rack-Mountable
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This PDU operates on a standard 120V AC input and output, compatible with common North American power systems. The electrical design supports a 30-amp capacity, protected by an integrated circuit breaker that automatically disconnects in the event of an overload, preventing damage to connected devices and the PDU itself.
The unit features a NEMA L5-30P locking plug for a secure connection to the power source, reducing the risk of accidental disconnection. All 20 output receptacles are NEMA 5-20R, the standard for 120V devices, arranged with 10 on the front and 10 on the rear to facilitate neat cable routing and improve airflow within the rack.
Protection & Safety
Overload protection via a circuit breaker ensures the PDU and connected equipment are shielded from excessive current draw, enhancing system reliability and safety in critical IT deployments.
Key Product Advantages
The CyberPower Basic PDU30BT10F10R combines essential power distribution features with a durable, space-efficient design, making it an ideal choice for IT professionals seeking a no-fuss, reliable rack PDU.
For buyers comparing similar models, the strongest advantage is usually the balance between dependable day-to-day operation and a simpler rollout experience. That means less time spent troubleshooting fit, compatibility, or user adoption after installation, which is especially important for shared business environments and repeat purchasing decisions.
Advantages are also easier to justify when they translate into measurable operational value, such as less downtime, more consistent user experience, easier replacement planning, or better alignment with existing accessories and workflows. That practical value tends to matter more than broad marketing language when teams are standardizing purchases.
Deployment / Use Cases
This PDU is specifically designed for rack-mounted IT infrastructure, providing centralized power distribution for servers, switches, routers, and other network equipment in data centers, server rooms, and network closets.
The front-and-rear outlet configuration is particularly useful for organizing power cables in standard 19-inch racks, allowing technicians to connect devices directly based on their physical location. This setup minimizes cable clutter, improves airflow for cooling, and simplifies maintenance and troubleshooting.
Data Center & Server Room Power
Deploy in standard 19-inch server racks to power multiple rack-mounted devices from a single, protected 30-amp circuit, ensuring clean power distribution and reducing the need for multiple wall outlets or power strips.
Network Closet & Telecom Rack
Ideal for smaller IT environments like network closets, providing reliable power to switches, patch panels, and other networking gear while maintaining a compact, organized footprint with vertical mounting.
Physical Profile
The PDU features a compact vertical design with dimensions of 1.75" (44.45 mm) in height, 17.50" (444.50 mm) in width, and 2.25" (57.15 mm) in depth, perfectly sized for a 1U rack space. Its weight of approximately 5.85 lb (2653.52 g) reflects the sturdy metal housing, which provides structural integrity and effective heat dissipation. The vertical orientation allows for easy installation and access to all outlets without occupying horizontal rack space.
- Width
- 17.50" (444.50 mm)
- Height
- 1U
- Weight
- 5.85 lb (2653.52 g)
- Length
- 2.25" (57.15 mm)
What's in the Box
The package includes the CyberPower Basic PDU30BT10F10R 20-Outlets PDU and a cord retention tray, providing everything needed for a secure rack installation. The cord retention tray helps manage power cables, keeping them organized and preventing strain on the connections.
Highlights
- 20 NEMA 5-20R output receptacles (10 front, 10 rear) for extensive device connectivity.
- 120V AC input and output with 30-amp electrical capacity and circuit breaker protection.
- 1U vertical rack-mountable design saves space in standard 19-inch server racks.
- Rugged industrial-grade metal housing ensures durability in demanding environments.
- NEMA L5-30P locking plug provides a secure, reliable power source connection.
- Overload protection safeguards connected equipment from electrical faults.
- RoHS compliant and environmentally friendly construction.
- Lifetime limited warranty for long-term peace of mind.
Specifications
| Specifications | |
|---|---|
| Manufacturer | CyberPower Systems, Inc |
| Manufacturer Part Number | PDU30BT10F10R |
| Brand Name | CyberPower |
| Product Series | Basic PDU |
| Product Name | Basic PDU30BT10F10R 20-Outlets PDU |
| Product Type | PDU |
| Technical Information | |
| PDU Type | Basic |
| Plug/Connector Type | NEMA L5-30P |
| Receptacle Type | NEMA 5-20R |
| Receptacle Detail | 20 x NEMA 5-20R |
| Protection Type | Overload Protection |
| Power Description | |
| Input Voltage | 120 V AC |
| Output Voltage | 120 V AC |
| Physical Characteristics | |
| Mounting Orientation | Vertical |
| Mount Type | Rack-mountable |
| Rack Height | 1U |
| Height | 1.75" (44.45 mm) |
| Width | 17.50" (444.50 mm) |
| Length | 2.25" (57.15 mm) |
| Weight (Approximate) | 5.85 lb (2653.52 g) |
| Miscellaneous | |
| Package Contents | Basic PDU30BT10F10R 20-Outlets PDU Cord Retention Tray |
| Energy Star | No |
| Environmentally Friendly | Yes |
| Environmental Compliance | Restriction of Hazardous Substances (RoHS) |
| Warranty | |
| Limited Warranty | Lifetime |
User Manual
FAQ
What is the input plug type on this CyberPower PDU?
The input plug is a NEMA L5-30P, a locking connector commonly used for 30-amp, 120V circuits in North America. This locking design ensures a secure connection to the power source, reducing the risk of accidental disconnection in rack environments.
How many outlets does this PDU have and how are they arranged?
This PDU has 20 NEMA 5-20R outlets, arranged with 10 on the front and 10 on the rear of the unit. This balanced layout allows for flexible cable management, helping to organize power cables based on device placement in the rack for improved airflow and accessibility.
What is the rack mounting configuration for this PDU?
It is designed for vertical mounting in a standard 19-inch rack, occupying 1U of rack height. The vertical orientation maximizes space efficiency, allowing it to be installed alongside other rack-mounted equipment without consuming additional horizontal space.
Does this PDU include any protection features?
Yes, it includes overload protection through an integrated circuit breaker. This feature automatically disconnects the power if the current draw exceeds the 30-amp capacity, protecting both the PDU and connected devices from potential damage due to electrical overloads.
What is the input and output voltage rating?
Both the input and output voltage are rated at 120 V AC, making it compatible with standard North American power systems. This ensures it can distribute power to typical IT equipment like servers, switches, and routers that operate on 120V.
What warranty is provided with this CyberPower PDU?
CyberPower offers a lifetime limited warranty for this PDU, providing long-term coverage against defects in materials and workmanship. This warranty underscores the product's durability and reliability for continuous use in business IT environments.
What power capacity is listed for this UPS?
Power specifications help show where the unit fits best, including the type of load level, electrical environment, and backup role it is intended to support. These are usually the most decision-critical facts in a UPS or power-protection comparison.
What voltage details are listed?
The listed power specification is 120 V AC, which helps position the unit for the right load level and installation role.