Shipping included*
Exclusions
Additional shipping fees may apply in rare circumstances for deliveries outside standard service areas. In most cases, this only potentially affects shipments to the Northwest Territories and Yukon, as well as certain heavy or oversized items.
CyberPower OL6000RT3UTAA Smart App Online UPS - 6 kVA / 5. 4 kW - 3U Rack/Tower - AVR - 5 Min Full Load Runtime - 230/120V AC Input
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This online UPS employs double conversion technology, continuously converting AC input to DC and back to clean AC output, providing complete isolation from utility power anomalies. The zero-transfer time ensures uninterrupted operation during power transitions, while AVR corrects voltage fluctuations without switching to battery power.
The system incorporates 20 sealed lead-acid batteries (12V, 7000 mAh each) that are hot-swappable and user-replaceable. Management capabilities include SNMP/HTTP remote monitoring, alarm notifications for battery mode, low battery, overload, and UPS fault conditions, plus dataline protection for RJ-11 and RJ-45 connections.
This section brings together practical product details such as AVR, Plug/Connector Type, Receptacle Type, Load Capacity (VA), so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
A strong technical summary explains how the product's interfaces, hardware profile, and operating characteristics work together in real deployment. Buyers often need this context to confirm compatibility with existing devices, expected performance in daily use, and whether installation will be straightforward for IT staff or end users.
Key Product Advantages
Enterprise-Grade Runtime & Capacity
With 6 kVA/5.4 kW capacity, this UPS supports substantial server and network loads, delivering 5 minutes of runtime at full load and 15 minutes at half load for orderly shutdowns or continued operation during brief outages.
Flexible Deployment Options
The 3U rack/tower design installs in standard 19-inch racks or stands independently, while NEMA L6-30P input and multiple NEMA L6-20R/L6-30R outputs accommodate North American commercial power configurations.
Comprehensive Monitoring & Management
An LCD control panel with 38 settings/status options, plus SNMP/HTTP remote monitoring, provides real-time visibility and control over UPS status, battery health, and power events from anywhere on the network.
Deployment / Use Cases
The OL6000RT3UTAA is engineered for environments where power quality and availability directly impact business continuity. Its 6 kVA capacity and double conversion topology make it ideal for protecting server racks, network equipment, VoIP systems, and other critical loads in data centers, enterprise installations, and industrial settings.
Typical deployments include rack-mounting alongside blade servers and switches in data center cabinets, or tower placement in network closets and telecom rooms. The TAA compliance ensures suitability for government and educational procurement, while Energy Star certification and RoHS environmental compliance address sustainability requirements.
This section brings together practical product details such as AVR, Plug/Connector Type, Receptacle Type, Load Capacity (VA), so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
Physical Profile
The UPS measures 5.25" (133.35 mm) high, 17" (431.80 mm) wide, and 26" (660.40 mm) deep, occupying 3U of rack space with a weight of 55 lb (24947.58 g). The rack/tower form factor includes mounting hardware for secure installation in standard 19-inch racks, while the tower configuration offers standalone stability for floor or shelf placement.
- Width
- 17" (431.80 mm)
- Depth
- 26" (660.40 mm)
- Height
- 5.25" (133.35 mm)
- Weight
- 55 dB(A)
What's in the Box
The package includes all necessary components for immediate deployment and management of the UPS system.
Highlights
- 6 kVA/5.4 kW load capacity for substantial server and network equipment protection
- Double conversion online topology with pure sine wave output and 0 ns transfer time
- 3U rack/tower form factor with mounting hardware for flexible installation
- 5-minute full-load runtime (15 minutes at half load) for orderly shutdowns
- Hot-swappable, user-replaceable batteries with 4-hour typical recharge time
- SNMP/HTTP remote monitoring with LCD control panel (38 settings/status options)
- AVR corrects voltage fluctuations without draining battery power
- TAA compliant for government and educational procurement requirements
- Energy Star certified with >96% efficiency in ECO Mode
- 3-year limited warranty for long-term reliability assurance
Specifications
| Specifications | |
|---|---|
| Manufacturer | CyberPower Systems, Inc |
| Manufacturer Part Number | OL6000RT3UTAA |
| Brand Name | CyberPower |
| Product Line | Smart App Online |
| Product Model | OL6000RT3UTAA |
| Product Name | OL6000RT3UTAA TAA UPS Systems |
| Product Type | Double Conversion Online UPS |
| Technical Information | |
| AVR | Yes |
| Plug/Connector Type | NEMA L6-30P |
| Receptacle Type | NEMA L6-20R,NEMA L6-30R |
| Receptacle Detail | 2 x NEMA L6-30R,2 x NEMA L6-20R |
| Dataline Protection | RJ-11,RJ-45 |
| Overload Protection | Yes |
| Transfer Time | 0 ns |
| EMI/RFI Noise Filter | Yes |
| Phase | Single Phase |
| Energy Saving | ECO Mode Efficiency >96% |
| Application/Usage | Server,Network Equipment,VoIP,Critical & Non-critical Load,Enterprise Installation,Mission Critical Equipment |
| Power Description | |
| Load Capacity (VA) | 6 kVA |
| Load Capacity (Watt) | 5.40 kW |
| Input Voltage | 230 V AC,120 V AC |
| Input Voltage Range | 120 V AC - 139 V AC,140 V AC - 159 V AC,160 V AC - 179 V AC,180 V AC - 280 V AC |
| Output Voltage | 200 V AC,208 V AC,220 V AC,230 V AC,240 V AC |
| Input Frequency | 70 Hz |
| Output Frequency | 60 Hz |
| Waveform Type | Sine Wave |
| Surge Energy Rating | 2430 J |
| Management | |
| Network Management | SNMP/HTTP Remote Monitoring |
| Alarm | Battery Mode,Low Battery,Overload,UPS Fault,Replace Battery |
| Controls/Indicators | |
| Status Indicators | LED Indicators: Power On (white) Line Mode (green) Battery Mode (yellow) Bypass Mode (yellow) Fault (red) Replace Battery (red) LCD Control Panel: 38 different settings or status options via the UPS Status menu, UPS Setup & Control menus, and run Testing/Battery Calibration menus. |
| Interfaces/Ports | |
| Serial Port | Yes |
| EPO Port | Yes |
| USB (HID Compliant) Port | Yes |
| Battery Information | |
| Number of Batteries | 20 |
| Battery Characteristics | Sealed |
| Battery Chemistry | Lead Acid |
| Battery Size | 12V |
| Battery Capacity | 7000 mAh |
| Backup/Run Time (Full Load) | 5 Minute |
| Backup/Run Time (Half Load) | 15 Minute |
| Hot Swappable | Yes |
| Typical Battery Recharge Time | 4 Hour |
| Replaceable Battery | Yes |
| Environmental Conditions | |
| Maximum Operating Elevation | 10000 ft (3048000 mm) |
| Maximum Storage Elevation | 50000 ft (15240000 mm) |
| Storage Temperature | 5°F (-15°C) - 113°F (45°C) |
| Operating Humidity | 0% - 90% |
| Storage Relative Humidity | 0% - 95% |
| Maximum Operating Temperature | 104°F (40°C) |
| Sound Emission (A-Weighted) | 55 dB(A) |
| Thermal Dissipation | 1912 BTU/h |
| Physical Characteristics | |
| Height | 5.25" (133.35 mm) |
| Width | 17" (431.80 mm) |
| Depth | 26" (660.40 mm) |
| Rack Height | 3U |
| Form Factor | Rack/Tower |
| Weight (Approximate) | 55 lb (24947.58 g) |
| Miscellaneous | |
| Package Contents | OL6000RT3UTAA TAA UPS Systems Mounting Hardware |
| Software Included | PowerPanel Business Edition |
| Energy Star | Yes |
| TAA Compliant | Yes |
| Environmentally Friendly | Yes |
| Environmental Compliance | Restriction of Hazardous Substances (RoHS) |
| Warranty | |
| Limited Warranty | 3 Year |
User Manual
FAQ
What is the power capacity of this CyberPower UPS?
The OL6000RT3UTAA provides 6 kVA (6000 VA) and 5.4 kW of load capacity, suitable for protecting multiple servers, network switches, and other critical equipment in enterprise environments.
How long does the battery backup last during a power outage?
At full load (5.4 kW), the UPS delivers 5 minutes of runtime. At half load (2.7 kW), runtime extends to 15 minutes, providing time for orderly shutdowns or continued operation during brief outages.
Can this UPS be installed in a standard server rack?
Yes, the 3U form factor is designed for standard 19-inch racks and includes mounting hardware. It also functions as a tower unit for standalone deployment in network closets or equipment rooms.
What management and monitoring features are included?
The UPS features SNMP/HTTP remote monitoring, an LCD control panel with 38 settings/status options, and alarm notifications for battery mode, low battery, overload, and fault conditions. It also includes serial, EPO, and USB (HID compliant) ports for connectivity.
Are the batteries user-replaceable?
Yes, the 20 sealed lead-acid batteries are hot-swappable and user-replaceable, minimizing downtime during maintenance. The typical recharge time after a full discharge is 4 hours.
What input and output voltages does this UPS support?
Input voltage accepts 230 V AC or 120 V AC, with a range from 120 V AC to 280 V AC. Output provides 200 V AC, 208 V AC, 220 V AC, 230 V AC, or 240 V AC pure sine wave power, ensuring compatibility with various equipment.
What power capacity is listed for this UPS?
The listed power specification is 6 kVA, which helps position the unit for the right load level and installation role.
What voltage details are listed?
The listed power specification is 230 V AC,120 V AC, which helps position the unit for the right load level and installation role.