Product Features
Technical Overview
Relevant factors for this section include PDU Type, Design, Phase, Input Voltage. When those points are considered together, they give buyers a clearer picture of how the product is equipped, how it fits into deployment, and what kind of day-to-day role it is meant to support.
Power Specifications
Operates on single-phase power with input voltage ranging from 200-240V AC and stable output across the same range. The 15A input current supports demanding rack equipment loads while maintaining electrical efficiency.
- Input Voltage: 230 V AC nominal
- Output Voltage: 200 V AC, 240 V AC
- Input Frequency: 60 Hz
Management & Monitoring
Network-enabled via RJ-45 port with comprehensive protocol support including SNMPv1/v3, HTTP/HTTPS, SSH, SSL/TLS, and CLI for remote monitoring and control. The front-panel LCD provides at-a-glance power metrics and status information.
- Protocols: IPv4/IPv6, SNMP, HTTP, SSH, TLS
- Local Display: LCD with LED indicators
- Remote Access: Web interface and CLI
Key Product Advantages
This CyberPower PDU combines precise power monitoring with robust distribution capabilities in a space-efficient rackmount design. The automatic transfer switch functionality ensures continuous power availability by seamlessly switching between input sources during primary power failures.
Intelligent Power Monitoring
The integrated metering system provides real-time visibility into power consumption, voltage, and current draw at the PDU level. This data enables proactive capacity planning and helps identify inefficient equipment before it causes operational issues.
- LCD display for local monitoring
- Remote management via network protocols
- Historical power usage tracking
Secure Power Distribution
Twelve IEC C13 outlets with cord retention trays prevent accidental disconnections in vibration-prone environments. Overload protection safeguards connected equipment while the metal construction ensures durability in demanding data center conditions.
- Cord retention for secure connections
- Overload circuit protection
- Metal housing for EMI shielding
Deployment / Use Cases
The PDU24004 is specifically designed for environments requiring reliable power distribution with monitoring capabilities. Its compact 1U form factor makes it ideal for space-constrained racks while providing sufficient outlets for typical server and networking equipment configurations.
In data center applications, this PDU enables precise power monitoring at the rack level, helping administrators track energy usage and optimize power allocation. The network management capabilities allow for remote monitoring and control, reducing the need for physical access to equipment racks for routine power management tasks.
Data Center Rack Power
Deploy in server racks to distribute power to multiple devices while monitoring consumption at the rack level. The 12 outlets support typical server, switch, and storage configurations with room for expansion.
- Server rack power distribution
- Network closet installations
- Equipment monitoring at rack level
Network Infrastructure Support
Provide clean, monitored power to networking equipment including switches, routers, and security appliances. The single-phase design matches standard commercial power configurations while the IEC outlets ensure compatibility with enterprise equipment.
- Network equipment power management
- Telecom rack installations
- Security system power distribution
Physical Profile
Constructed with a durable metal housing in black finish, this PDU measures 1.75" (44.45 mm) in height, 17.05" (433.07 mm) in width, and 8.45" (214.63 mm) in depth. The 1U rackmount design with horizontal orientation fits standard 19-inch server racks, while the 10-foot power cord provides flexibility in rack placement relative to power sources.
- Width
- 17.05" (433.07 mm)
- Depth
- 8.45" (214.63 mm)
- Height
- 1U
- Weight
- 7.41 lb (3360 g)
- Length
- 10 ft (3.05 m)
Highlights
- Metered ATS PDU with LCD display for real-time power monitoring
- Single-phase 200-240V AC input with 15A capacity
- 12 IEC C13 outlets with cord retention trays
- 1U horizontal rackmount design for space-efficient installation
- Network management via RJ-45 with SNMP, HTTP, SSH support
- Overload protection safeguards connected equipment
- 10-foot power cord provides installation flexibility
- 3-year limited warranty with RoHS environmental compliance
- Metal construction for durability in data center environments
- Automatic transfer switch for continuous power availability
Specifications
| Specifications | |
|---|---|
| Manufacturer | CyberPower Systems, Inc |
| Manufacturer Part Number | PDU24004 |
| Brand Name | CyberPower |
| Product Series | Metered ATS PDU |
| Product Model | PDU24004 |
| Product Name | PDU24004 |
| Product Type | PDU |
| Technical Information | |
| PDU Type | Metered |
| Design | Modular |
| Phase | Single Phase |
| Plug/Connector Type | IEC 60320 C14 |
| Plug/Connector Detail | 2 x IEC 60320 C14 |
| Receptacle Type | IEC 60320 C13 |
| Receptacle Detail | 12 x IEC 60320 C13 |
| Protection Type | Overload Protection |
| Locking Receptacles | Cord Retention Tray |
| Features | LCD Display,LED Status Indicator |
| Power Description | |
| Input Voltage | 230 V AC |
| Input Voltage Range | 200 V AC - 240 V AC |
| Output Voltage | 200 V AC,240 V AC |
| Output Voltage Range | 200 V AC - 240 V AC |
| Input Current | 15 A |
| Input Frequency | 60 Hz |
| Management | |
| Management | Protocols: IPv4 TCP IP UDP SNMPv1 HTTP NTP DNS Telnet DHCP SMTP FTP IPv6 SNMPv3 HTTPs SSH SSL TLS LDAP(S) RADIUS Syslog CLI Windows AD SNMP |
| Interfaces/Ports | |
| Network (RJ-45) | Yes |
| Physical Characteristics | |
| Color Family | Black |
| Product Color | Black |
| Product Material | Metal |
| Mounting Orientation | Horizontal |
| Mount Type | Rack-mountable |
| Form Factor | Rack |
| Rack Height | 1U |
| Cord Length | 10 ft (3.05 m) |
| Height | 1.75" (44.45 mm) |
| Width | 17.05" (433.07 mm) |
| Depth | 8.45" (214.63 mm) |
| Weight (Approximate) | 7.41 lb (3360 g) |
| Environmental Conditions | |
| Minimum Operating Temperature | 32°F (0°C) |
| Maximum Operating Temperature | 113°F (45°C) |
| Minimum Storage Temperature | 5°F (-15°C) |
| Maximum Storage Temperature | 131°F (55°C) |
| Miscellaneous | |
| Application/Usage | Data Center,Network Closet |
| Country of Origin | China |
| Environmentally Friendly | Yes |
| Environmental Compliance | Restriction of Hazardous Substances (RoHS) |
| Warranty | |
| Limited Warranty | 3 Year |
User Manual
FAQ
What is the input voltage range for this CyberPower PDU?
The PDU24004 accepts single-phase input voltage from 200-240V AC, with a nominal voltage of 230V AC. This range accommodates standard commercial power configurations in North America and other regions with similar voltage standards. The output maintains the same voltage range to ensure consistent power delivery to connected equipment.
How many devices can I power with this rack PDU?
This PDU provides twelve IEC C13 outlets, allowing you to power up to twelve compatible devices simultaneously. The 15A input current supports substantial power loads typical of server rack environments. Each outlet features cord retention trays to prevent accidental disconnections in vibration-prone settings.
What rack space does this PDU require for installation?
The PDU24004 occupies 1U of vertical space in a standard 19-inch server rack with horizontal mounting orientation. Its dimensions are 1.75 inches in height, 17.05 inches in width, and 8.45 inches in depth. This compact form factor maximizes usable rack space while providing comprehensive power distribution capabilities.
How does the automatic transfer switch (ATS) function work?
The ATS capability automatically switches between primary and secondary power sources if the primary source fails or experiences issues. This ensures continuous power availability to connected equipment without manual intervention. The metering function provides visibility into both power sources, allowing administrators to monitor the status of each input.
What management protocols does this PDU support?
This network-managed PDU supports comprehensive protocols including SNMPv1/v3, HTTP/HTTPS, SSH, SSL/TLS, IPv4/IPv6, and CLI for remote monitoring and control. The RJ-45 network port enables integration with existing network management systems, while the local LCD display provides at-a-glance status information without requiring network access.
What protection features does this power distribution unit include?
The PDU24004 incorporates overload protection to safeguard connected equipment against excessive current draw. The metal housing provides EMI shielding and physical durability, while cord retention trays prevent accidental disconnections. The unit operates within a temperature range of 32°F to 113°F (0°C to 45°C) and complies with RoHS environmental standards.