CyberPower PDU83111 Switched Metered-by-Outlet PDU - 3 Phase 20A - 30 Outlets - 24 C13 + 6 C19 - 0U Vertical Rackmount - 10 ft Cord
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This PDU operates on a three-phase power system with an input voltage range of 346–415 V AC and delivers output at 200–240 V AC, suitable for global data center standards. The 20A input current supports high-density power distribution, with each outlet individually metered for real-time power consumption tracking.
Network management is comprehensive, supporting both IPv4 and IPv6 along with protocols like SNMPv1/v3, HTTP/HTTPS, SSH, and TLS for secure remote access. Integration with Windows Active Directory and RADIUS enables centralized authentication, while Syslog and CLI support facilitate logging and scripting for automated power control.
This section brings together practical product details such as PDU Type, Phase, Plug/Connector Type, Input Voltage Range, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
A strong technical summary explains how the product's interfaces, hardware profile, and operating characteristics work together in real deployment. Buyers often need this context to confirm compatibility with existing devices, expected performance in daily use, and whether installation will be straightforward for IT staff or end users.
Key Product Advantages
The PDU83111 combines advanced monitoring with robust power distribution, offering visibility and control at the outlet level to optimize energy usage and prevent overloads. Remote outlet switching allows administrators to power cycle equipment without physical access, reducing downtime and maintenance costs.
Precision Power Monitoring
Metered-by-outlet functionality provides real-time data on current draw per outlet, enabling capacity planning and identifying underutilized or overloaded circuits.
- Track power consumption per device
- Set thresholds for alerts
- Generate usage reports for billing or analysis
Enterprise-Grade Management
Support for SNMP, HTTPS, SSH, and other protocols ensures seamless integration into existing network management systems, with security features like TLS and RADIUS for protected access.
- Secure remote access via encrypted protocols
- Compatible with network monitoring tools
- Centralized authentication through AD/LDAP
Deployment / Use Cases
Ideal for data centers, server rooms, and network closets, the PDU83111 supports high-density environments where reliable power distribution and monitoring are critical. Its vertical 0U design saves rack space for equipment, while the mix of C13 and C19 outlets accommodates everything from servers and switches to storage arrays and UPS units.
In colocation facilities, the per-outlet metering allows for accurate power billing to tenants, and remote management capabilities reduce the need for on-site visits. For IT departments, the ability to schedule power cycles or respond to alerts remotely enhances operational efficiency and minimizes service interruptions.
Data Center Power Distribution
Distribute three-phase power to multiple racks with individual outlet control and monitoring, ensuring balanced loads and preventing circuit overloads.
Remote Site Management
Manage power for equipment in branch offices or remote locations via network connectivity, reducing travel costs and improving response times to issues.
Physical Profile
The PDU83111 features a vertical mounting orientation with a 0U rack height, fitting neatly alongside equipment without consuming rack units. Its dimensions are 70.50 inches in height, 2.20 inches in width, and 2.20 inches in depth, with a weight of approximately 17 pounds, making it easy to install in standard racks. The black color and sleek design ensure it blends into professional environments, while the 10-foot cord provides flexibility in placement relative to power sources.
- Width
- 2.20" (55.88 mm)
- Depth
- 2.20" (55.88 mm)
- Height
- 0U
- Weight
- 17 lb (7711.07 g)
- Length
- 10 ft (3.05 m)
Highlights
- Three-phase power distribution with 20A input capacity
- Metered-by-outlet monitoring for individual power tracking
- 30 total outlets: 24 IEC C13 and 6 IEC C19
- Vertical 0U rackmount design saves space
- Network management via SNMP, HTTP/HTTPS, SSH, and more
- Remote outlet switching for power control
- 10-foot power cord with IEC 60309 20A red connector
- 3-year limited warranty for reliability assurance
Specifications
| Specifications | |
|---|---|
| Manufacturer | CyberPower Systems, Inc |
| Manufacturer Part Number | PDU83111 |
| Brand Name | CyberPower |
| Product Series | Switched Metered-by-Outlet PDU |
| Product Model | PDU83111 |
| Product Name | PDU83111 3 Phase 200 - 240 VAC 20A Switched Metered-by-Outlet |
| Product Condition | New |
| Product Type | PDU |
| Technical Information | |
| PDU Type | Switched with Metered-by-Outlet |
| Phase | Three Phase |
| Plug/Connector Type | IEC 60309 20A Red (3P+N+E) |
| Receptacle Type | IEC 60320 C13,IEC 60320 C19 |
| Receptacle Detail | 24 x IEC 60320 C13,6 x IEC 60320 C19 |
| Power Description | |
| Input Voltage Range | 346 V AC - 415 V AC |
| Output Voltage Range | 200 V AC - 240 V AC |
| Input Current | 20 A |
| Management | |
| Management | IPv4 TCP/IP UDP SNMPv1 HTTP NTP DNS Telnet DHCP SMTP FTP IPv6 SNMPv3 HTTPs SSH SSL TLS LDAP(S) RADIUS Syslog CLI Windows AD |
| Remote Outlet Switching | Yes |
| Interfaces/Ports | |
| Network (RJ-45) | Yes |
| Physical Characteristics | |
| Color Family | Black |
| Product Color | Black |
| Mounting Orientation | Vertical |
| Mount Type | Rack-mountable |
| Rack Height | 0U |
| Cord Length | 10 ft (3.05 m) |
| Height | 70.50" (1790.70 mm) |
| Width | 2.20" (55.88 mm) |
| Depth | 2.20" (55.88 mm) |
| Weight (Approximate) | 17 lb (7711.07 g) |
| Miscellaneous | |
| Country of Origin | Philippines |
| Warranty | |
| Limited Warranty | 3 Year |
User Manual
FAQ
What is the input voltage range for this PDU?
The CyberPower PDU83111 accepts an input voltage range of 346–415 V AC, which is typical for three-phase power systems in data centers. It outputs 200–240 V AC to connected equipment, ensuring compatibility with standard IT devices.
How many outlets does this PDU have and what types?
This PDU has 30 outlets total: 24 are IEC 60320 C13 receptacles, commonly used for servers and networking gear, and 6 are IEC 60320 C19 receptacles, which support higher-power devices like larger servers or UPS units.
What management features are included?
The PDU83111 supports comprehensive network management, including IPv4 and IPv6, SNMPv1/v3 for monitoring, HTTP/HTTPS and SSH for secure access, and protocols like TLS, LDAP(S), and RADIUS for authentication. It also allows remote outlet switching and integrates with Windows Active Directory.
Is this PDU rack-mountable and what are its dimensions?
Yes, it is designed for vertical rack mounting with a 0U height, meaning it does not consume rack units. Its dimensions are 70.50 inches in height, 2.20 inches in width, and 2.20 inches in depth, with a weight of about 17 pounds, making it suitable for standard 19-inch racks.
What is the cord length and connector type?
The PDU comes with a 10-foot (3.05-meter) power cord that terminates in an IEC 60309 20A red connector (3P+N+E), providing flexibility in placement and ensuring a secure connection to three-phase power sources.
What warranty does this product include?
CyberPower provides a 3-year limited warranty for the PDU83111, covering defects in materials and workmanship. This warranty supports reliable operation in critical environments like data centers.
What power capacity is listed for this UPS?
Power specifications help show where the unit fits best, including the type of load level, electrical environment, and backup role it is intended to support. These are usually the most decision-critical facts in a UPS or power-protection comparison.
How many outlets are available?
The product includes Yes, which helps buyers understand how many connected devices it can support in its intended deployment.