Shipping included*
Exclusions
Additional shipping fees may apply in rare circumstances for deliveries outside standard service areas. In most cases, this only potentially affects shipments to the Northwest Territories and Yukon, as well as certain heavy or oversized items.
CyberPower PR3000RTXL2UCN Smart App Sinewave UPS - 3000VA/3000W - 2U Rack/Tower - 9 Outlets - Sine Wave Output
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This UPS employs GreenPower UPS™ bypass technology for energy efficiency while maintaining robust protection. The electrical design includes wide input voltage tolerance from 70-155 V AC and output stabilization at 100-120 V AC with ±5% regulation.
Battery configuration consists of four sealed lead-acid 12V batteries with 9000 mAh capacity, supporting hot-swappable replacement without system downtime. The unit provides 7 minutes of runtime at half load and 1.7 minutes at full load, with typical recharge completing in 3 hours.
This section brings together practical product details such as AVR, Plug/Connector Type, Receptacle Type, Load Capacity (VA), so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
A strong technical summary explains how the product's interfaces, hardware profile, and operating characteristics work together in real deployment. Buyers often need this context to confirm compatibility with existing devices, expected performance in daily use, and whether installation will be straightforward for IT staff or end users.
Key Product Advantages
Pure Sine Wave Output
Delivers clean, stable power compatible with active PFC power supplies found in servers, network equipment, and storage devices, preventing equipment damage and ensuring optimal performance.
- Compatible with sensitive electronics
- Prevents equipment damage
- Maintains power quality
Comprehensive Management
LCD display provides real-time status monitoring, while network management capabilities include SNMP/HTTP remote monitoring, dry contact relay, and support for network management cards.
- Real-time status monitoring
- Remote management capabilities
- Multiple interface options
Flexible Deployment
2U rack-mountable design with optional tower configuration adapts to various installation environments, from standard server racks to standalone tower setups.
- Rack or tower deployment
- Space-efficient 2U height
- Installation flexibility
Deployment / Use Cases
The PR3000RTXL2UCN is engineered for protecting critical infrastructure where power continuity is essential. Its 3000VA capacity and nine outlet configuration make it suitable for supporting multiple devices simultaneously while maintaining clean power delivery.
Primary deployment scenarios include network closets protecting switches and routers, server rooms supporting rack-mounted equipment, telecommunications installations maintaining VoIP systems, and corporate environments securing storage devices and network equipment.
This section brings together practical product details such as AVR, Plug/Connector Type, Receptacle Type, Load Capacity (VA), so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
Server Room Protection
Provides backup power for rack-mounted servers, storage arrays, and network switches during outages, with pure sine wave output ensuring compatibility with server power supplies.
Network Infrastructure
Protects telecommunications equipment, VoIP phone systems, and network devices with its nine outlet configuration and surge suppression capabilities.
Physical Profile
The black chassis measures 3.40" (86.36 mm) in height, 17.10" (434.34 mm) in width, and 19.70" (500.38 mm) in depth, fitting standard 19-inch server racks at 2U height. The 75.40 lb weight reflects robust construction with internal battery complement.
The physical profile is practical for deployment planning because the dimensions and weight are clearly defined: 3.40" (86.36 mm), 17.10" (434.34 mm), 19.70" (500.38 mm), 57.5 dB(A). This helps confirm rack, shelf, desk, or cabinet fit before installation.
- Width
- 17.10" (434.34 mm)
- Depth
- 19.70" (500.38 mm)
- Height
- 3.40" (86.36 mm)
- Weight
- 57.5 dB(A)
- Length
- 10 ft (3.05 m)
Highlights
- 3000VA/3000W power capacity for robust backup protection
- Pure sine wave output compatible with sensitive electronic equipment
- 2U rack/tower form factor for flexible deployment options
- Nine total outlets with four critical load outlets
- LCD display with comprehensive status indicators
- Network management via SNMP/HTTP, dry contact, and management cards
- Hot-swappable battery design for maintenance without downtime
- Automatic voltage regulation (AVR) for stable power output
- Energy Star certified with GreenPower UPS™ technology
- Three-year limited warranty for long-term reliability
Specifications
| Specifications | |
|---|---|
| Manufacturer | CyberPower Systems, Inc |
| Manufacturer Part Number | PR3000RTXL2UCN |
| Brand Name | CyberPower |
| Product Series | New Smart App Sinewave UPS |
| Product Model | PR3000RTXL2UCN |
| Product Name | PR3000RTXL2UCN Smart App Sinewave UPS Systems |
| Product Type | Line-interactive UPS |
| Technical Information | |
| AVR | Yes |
| Plug/Connector Type | NEMA L5-30P |
| Receptacle Type | NEMA 5-20R,NEMA L5-30R |
| Receptacle Detail | 8 x NEMA 5-20R,1 x NEMA L5-30R |
| Number of Battery & Surge Outlets | 9 |
| Number of Critical Load Outlets | 4 |
| Overload Protection | Yes |
| Cord Length | 10 ft (3.05 m) |
| Transfer Time | 13 ms |
| EMI/RFI Noise Filter | Yes |
| Energy Saving | GreenPower UPS™ Bypass Technology |
| Application/Usage | Network,Server,Telecommunication,VoIP Phone System,Equipment,Storage Device,Network Device,Corporate |
| Surge Suppression | Yes |
| Features | Audible Alarm |
| Power Description | |
| Load Capacity (VA) | 3 kVA |
| Load Capacity (Watt) | 3 kW |
| Input Voltage | 120 V AC |
| Input Voltage Range | 100 V AC - 120 V AC,75 V AC - 149 V AC,70 V AC - 155 V AC |
| Output Voltage | 100 V AC,110 V AC,120 V AC |
| Input Frequency | 47 Hz,63 Hz |
| Output Frequency | 50 Hz,60 Hz |
| Waveform Type | Sine Wave |
| Surge Energy Rating | 2430 J |
| Circuit Breaker | Yes |
| Output Power Factor | 1 |
| Display & Graphics | |
| Display | LCD |
| Management | |
| Network Management | SNMP/HTTP Remote Monitoring,Network Card,Dry Contact,Relay-MS Card |
| Alarm | Battery Mode,Low Battery,Overload,Over-charge,Overheat |
| Controls/Indicators | |
| Status Indicators | LED Indicators: Power On Line Mode Battery Mode Fault Night Mode Wiring Fault |
| Interfaces/Ports | |
| Serial Port | Yes |
| Network (RJ-45) | Yes |
| EPO Port | Yes |
| USB (HID Compliant) Port | Yes |
| Battery Information | |
| Number of Batteries | 4 |
| Battery Characteristics | Sealed |
| Battery Chemistry | Lead Acid |
| Battery Size | 12V |
| Battery Capacity | 9000 mAh |
| Backup/Run Time (Full Load) | 1.70 Minute |
| Backup/Run Time (Half Load) | 7 Minute |
| Hot Swappable | Yes |
| Typical Battery Recharge Time | 3 Hour |
| Replaceable Battery | Yes |
| Environmental Conditions | |
| Maximum Operating Elevation | 9843 ft (3000146.40 mm) |
| Maximum Storage Elevation | 49213 ft (15000122.40 mm) |
| Storage Temperature | 5°F (-15°C) - 113°F (45°C) |
| Storage Relative Humidity | 0% - 95% |
| Minimum Operating Temperature | 32°F (0°C) |
| Maximum Operating Temperature | 104°F (40°C) |
| Sound Emission (A-Weighted) | 57.5 dB(A) |
| Thermal Dissipation | 192.50 BTU/h |
| Physical Characteristics | |
| Product Color | Black |
| Height | 3.40" (86.36 mm) |
| Width | 17.10" (434.34 mm) |
| Depth | 19.70" (500.38 mm) |
| Rack Height | 2U |
| Form Factor | Rack/Tower |
| Weight (Approximate) | 75.40 lb (34200.86 g) |
| Miscellaneous | |
| Energy Star | Yes |
| Environmental Compliance | Restriction of Hazardous Substances (RoHS) |
| Warranty | |
| Limited Warranty | 3 Year |
User Manual
FAQ
What is the power capacity of this CyberPower UPS?
The PR3000RTXL2UCN provides 3000VA/3000W of power capacity, making it suitable for protecting multiple servers, network switches, storage devices, or telecommunications equipment simultaneously. This capacity supports critical infrastructure during power outages while maintaining clean sine wave output.
How long does the battery backup last during a power outage?
At half load (1500W), the UPS provides approximately 7 minutes of runtime, while at full load (3000W), it delivers about 1.7 minutes of backup power. These runtime figures allow for graceful shutdown of connected equipment or short-term ride-through of brief power interruptions.
Can this UPS be installed in a server rack?
Yes, the unit features a 2U rack-mountable design that fits standard 19-inch server racks, with dimensions of 3.40" height, 17.10" width, and 19.70" depth. It also supports tower configuration for standalone deployment where rack mounting isn't available.
What type of power output does this UPS provide?
This UPS delivers pure sine wave output, which is essential for compatibility with modern server power supplies, network equipment, and sensitive electronics. Sine wave output prevents equipment damage and ensures optimal performance compared to simulated sine wave alternatives.
How many outlets does this UPS have, and what types are included?
The unit features nine total outlets: eight NEMA 5-20R outlets and one NEMA L5-30R outlet. Four of these are designated as critical load outlets for essential equipment, with all outlets providing battery backup and surge protection.
What management and monitoring capabilities are available?
Management options include an LCD display for local status monitoring, SNMP/HTTP remote monitoring capabilities, support for network management cards, dry contact relay interface, and USB connectivity. These features enable comprehensive monitoring and control of power status and UPS health.
What power capacity is listed for this UPS?
The listed power specification is 3 kVA, which helps position the unit for the right load level and installation role.
How many outlets are available?
The product includes 9, which helps buyers understand how many connected devices it can support in its intended deployment.