Eaton 9PX6KP1G2 9PX G2 6000VA/5. 4kW Double Conversion Online UPS - 6U Rack/Tower - 3 Hour Recharge - Pure Sine Wave
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This Eaton 9PX G2 UPS employs double conversion online topology, continuously converting AC input to DC and back to AC, providing complete isolation from utility power anomalies. The pure sine wave output maintains compatibility with sensitive electronic equipment, while the 0.9 output power factor optimizes real power delivery.
Advanced Battery Management (ABM+) extends battery life through intelligent charging algorithms, and the built-in bypass switch allows maintenance without disrupting connected loads. The LCD display provides real-time status monitoring, supported by LED indicators and audible alarms for utility failure, low battery, overload, UPS fault, battery fault, and remote shutdown conditions.
Efficiency Performance
Achieves 96% efficiency in AC mode and 98.9% in Eco Mode, reducing energy costs and heat generation while maintaining power quality.
- 96% AC Mode Efficiency
- 98.9% Eco Mode Efficiency
- 1155 BTU/h Thermal Dissipation
Key Product Advantages
The Eaton 9PX6KP1G2 combines high power capacity with flexible deployment options and comprehensive management capabilities for enterprise-grade power protection.
Flexible Power Distribution
Includes a NEMA L6-30P input plug and eight output receptacles: six NEMA 5-20R, one NEMA L6-30R, and one NEMA L14-30R, accommodating diverse equipment connections with a 10-foot power cord.
- 6 x NEMA 5-20R Outlets
- 1 x NEMA L6-30R Outlet
- 1 x NEMA L14-30R Outlet
Comprehensive Connectivity
Features serial, USB, and EPO ports alongside support for Network-M3, INDGW-M2, and Relay-MS management cards, enabling remote monitoring and control through Eaton's software ecosystem.
- Serial & USB Ports
- EPO Port
- Network Card Slots
Deployment / Use Cases
The Eaton 9PX G2 6000VA UPS is engineered for environments where power continuity directly impacts operational integrity and data preservation. Its 6U rack-mountable form factor with optional tower stands suits both data center racks and server room floor deployments.
In data center applications, the UPS protects server racks, network switches, and storage arrays from power disturbances, while the 3-minute full-load runtime allows for automated shutdown procedures or transfer to backup generators. For edge computing and network equipment in retail, healthcare, or government settings, it ensures uninterrupted operation of point-of-sale systems, medical devices, and security infrastructure.
IT Equipment Protection
Safeguards servers, switches, and network equipment in data centers and network closets with pure sine wave output and surge suppression.
- Server Racks
- Network Switches
- Storage Arrays
Critical Infrastructure Support
Provides backup power for electronic systems in education, healthcare, and government facilities where uptime is essential for service delivery.
- Healthcare Devices
- Government Systems
- Educational Infrastructure
Physical Profile
The Eaton 9PX6KP1G2 measures 10.20" (259.08 mm) in height, 17.30" (439.42 mm) in width, and 27" (685.80 mm) in depth, occupying 6U of rack space. At 203 pounds (92079.25 g), it requires proper rack reinforcement or use of the included tower support stands for floor placement. The design accommodates standard 19-inch racks with front-to-back airflow compatibility.
The physical profile is practical for deployment planning because the dimensions and weight are clearly defined: 10.20" (259.08 mm), 17.30" (439.42 mm), 27" (685.80 mm), 203 lb (92079.25 g). This helps confirm rack, shelf, desk, or cabinet fit before installation.
- Width
- 17.30" (439.42 mm)
- Depth
- 27" (685.80 mm)
- Height
- 10.20" (259.08 mm)
- Weight
- 203 lb (92079.25 g)
- Length
- 10 ft (3.05 m)
What's in the Box
The package includes all necessary components for immediate deployment in rack or tower configurations.
Highlights
- 6000VA/5.4kW double conversion online UPS for mission-critical equipment protection
- 3-minute runtime at full load and 8.3 minutes at half load for graceful shutdowns
- 6U rack/tower form factor with included tower stands for flexible deployment
- Pure sine wave output with 96% efficiency in AC mode for clean, reliable power
- Hot-swappable, valve-regulated lead-acid batteries with 3-hour typical recharge
- Eight output receptacles: six NEMA 5-20R, one NEMA L6-30R, one NEMA L14-30R
- Advanced Battery Management (ABM+) and built-in bypass switch for maintenance
- Network management via Network-M3, INDGW-M2, or Relay-MS cards
- LCD display with LED indicators and audible alarms for status monitoring
- 3-year limited warranty with Energy Star certification and RoHS compliance
Specifications
| Specifications | |
|---|---|
| Manufacturer | Eaton Corporation |
| Manufacturer Part Number | 9PX6KP1G2 |
| Brand Name | Eaton |
| Product Series | 9PX G2 |
| Product Model | 9PX6KP1G2 |
| Product Name | 9PX G2 9PX6KP1G2 6000VA Rack/tower UPS |
| Product Type | Double Conversion Online UPS |
| Technical Information | |
| Plug/Connector Type | NEMA L6-30P |
| Receptacle Type | NEMA 5-20R,NEMA L6-30R,NEMA L14-30R |
| Receptacle Detail | 6 x NEMA 5-20R,1 x NEMA L6-30R,1 x NEMA L14-30R |
| Cord Length | 10 ft (3.05 m) |
| EMI/RFI Noise Filter | Yes |
| Phase | Single Phase |
| Efficiency Detail | 96% (AC Mode),98.9% (Eco Mode) |
| Application/Usage | Mission Critical Equipment,Network,IT Equipment,Data Center,Electronic,Edge Computing,Education,Government,Healthcare,Retail,Server,Switch,Network Equipment |
| Surge Suppression | Yes |
| Features | Built-in Bypass Switch,Audible Alarm,Advanced Battery Management (ABM+) |
| Power Description | |
| Load Capacity (VA) | 6 kVA |
| Load Capacity (Watt) | 5.40 kW |
| Input Voltage | 230 V AC |
| Input Current | 24.40 A |
| Output Voltage | 240 V AC,230 V AC,220 V AC,208 V AC,200 V AC,100 V AC,110 V AC,120 V AC |
| Output Frequency | 50 Hz,60 Hz |
| Waveform Type | Pure Sine Wave |
| Output Power Factor | 0.9 |
| Display & Graphics | |
| Display | LCD |
| Management | |
| Network Management | Network-M3 Card,INDGW-M2 Card,Relay-MS Card |
| Alarm | Utility Power Failure,Low Battery,Overload,UPS Fault,Battery Fault,Remote Shutdown |
| Controls/Indicators | |
| Status Indicators | LED Indicators |
| Interfaces/Ports | |
| Serial Port | Yes |
| USB | Yes |
| EPO Port | Yes |
| Battery Information | |
| DC System Voltage | 180 V DC |
| Battery Characteristics | Valve-regulated |
| Battery Chemistry | Lead Acid |
| Backup/Run Time (Full Load) | 3 Minute |
| Backup/Run Time (Half Load) | 8.30 Minute |
| Hot Swappable | Yes |
| Typical Battery Recharge Time | 3 Hour |
| Replaceable Battery | Yes |
| Environmental Conditions | |
| Minimum Operating Temperature | 32°F (0°C) |
| Maximum Operating Temperature | 104°F (40°C) |
| Thermal Dissipation | 1155 BTU/h |
| Physical Characteristics | |
| Height | 10.20" (259.08 mm) |
| Width | 17.30" (439.42 mm) |
| Depth | 27" (685.80 mm) |
| Rack Height | 6U |
| Form Factor | Rack/Tower |
| Weight (Approximate) | 203 lb (92079.25 g) |
| Miscellaneous | |
| Package Contents | 9PX G2 9PX6KP1G2 6000VA Rack/tower UPS 9PXPPDM1G2 PowerPass Distribution Module with Maintenance Bypass NETWORK-M3 Gigabit Network Card USB Cable RS-232 Cable Rack-mounting Hardware Tower Support Stands Quick Start Guide |
| Energy Star | Yes |
| Environmental Compliance | Restriction of Hazardous Substances (RoHS) |
| Warranty | |
| Limited Warranty | 3 Year |
FAQ
What is the power capacity of the Eaton 9PX6KP1G2 UPS?
The Eaton 9PX6KP1G2 provides 6000VA (6 kVA) and 5400W (5.4 kW) of power capacity with a 0.9 output power factor. This double conversion online UPS delivers pure sine wave output suitable for protecting servers, network equipment, and other mission-critical IT infrastructure from power disturbances.
How long does this UPS provide backup power during an outage?
At full load, the UPS offers 3 minutes of runtime, while at half load it provides 8.3 minutes. This runtime allows sufficient time for connected equipment to perform graceful shutdowns or for backup generators to engage, protecting data and preventing hardware damage from abrupt power loss.
Can this UPS be installed in both rack and tower configurations?
Yes, the Eaton 9PX6KP1G2 features a rack/tower form factor that occupies 6U of rack space and includes tower support stands for floor deployment. The unit measures 10.20" high, 17.30" wide, and 27" deep, making it compatible with standard 19-inch server racks while offering flexibility for environments without rack infrastructure.
What types of power outlets does this UPS include?
This UPS includes eight output receptacles: six NEMA 5-20R, one NEMA L6-30R, and one NEMA L14-30R. These accommodate various equipment connections, from standard IT devices to higher-power equipment. The unit comes with a 10-foot NEMA L6-30P input cord for connection to appropriate power sources.
How is the Eaton 9PX6KP1G2 managed and monitored?
Management options include an LCD display with LED indicators, serial and USB ports for local monitoring, and support for Network-M3, INDGW-M2, or Relay-MS network management cards for remote oversight. The UPS features audible alarms for conditions like utility failure, low battery, overload, and system faults, enabling prompt response to power events.
What is the battery recharge time and maintenance requirement?
The typical battery recharge time is 3 hours after a complete discharge. Batteries are hot-swappable and replaceable, allowing maintenance without shutting down connected equipment. Advanced Battery Management (ABM+) optimizes charging to extend battery life, and the valve-regulated lead-acid batteries operate within 32°F to 104°F (0°C to 40°C) environmental ranges.
What power capacity is listed for this UPS?
The listed power specification is 6 kVA, which helps position the unit for the right load level and installation role.
What voltage details are listed?
The listed power specification is 230 V AC, which helps position the unit for the right load level and installation role.