Shipping included*
Exclusions
Additional shipping fees may apply in rare circumstances for deliveries outside standard service areas. In most cases, this only potentially affects shipments to the Northwest Territories and Yukon, as well as certain heavy or oversized items.
Eaton 9PX8KG2 9PX G2 8000VA/8kW Rack/Tower UPS - 4U - 230V AC Input - 200-240V AC Output - 5. 4 Min Full Load Runtime
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This double conversion online UPS continuously conditions incoming power, isolating connected equipment from utility anomalies. The hardwired input accepts 230V AC via a NEMA L6-30R connector, while the output delivers adjustable voltage from 200V to 240V AC across four NEMA L6-30R receptacles.
Management capabilities include an LCD display, LED status indicators, and support for multiple network cards (INDGW-M2, Relay-MS, Network-M3) for remote monitoring via serial, USB, or EPO ports. Alarms cover utility failure, low battery, overload, UPS fault, battery fault, and remote shutdown scenarios.
This section brings together practical product details such as Plug/Connector Type, Receptacle Type, Receptacle Detail, Load Capacity (VA), so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
A strong technical summary explains how the product's interfaces, hardware profile, and operating characteristics work together in real deployment. Buyers often need this context to confirm compatibility with existing devices, expected performance in daily use, and whether installation will be straightforward for IT staff or end users.
Key Product Advantages
These strengths make the product easier to deploy and manage in real environments, especially where reliability, usability, and day-to-day operational continuity matter. Notable benefits include High-Efficiency Operation, Hot-Swappable Battery Design, Comprehensive Power Protection.
For buyers comparing similar models, the strongest advantage is usually the balance between dependable day-to-day operation and a simpler rollout experience. That means less time spent troubleshooting fit, compatibility, or user adoption after installation, which is especially important for shared business environments and repeat purchasing decisions.
High-Efficiency Operation
Achieves 96.5% efficiency in AC mode and 99.4% in Eco Mode, reducing energy costs and heat generation in continuous-use environments.
Hot-Swappable Battery Design
Valve-regulated lead-acid batteries are user-replaceable without powering down the UPS, maintaining uptime during maintenance.
Comprehensive Power Protection
Combines surge suppression, EMI/RFI filtering, and pure sine wave output to safeguard sensitive electronics from electrical disturbances.
Deployment / Use Cases
The Eaton 9PX8KG2 is tailored for environments where power continuity is non-negotiable. Its 8 kVA capacity and rack/tower flexibility make it suitable for protecting high-density server racks, network switches, PoE systems, and storage arrays in data centers and enterprise IT rooms.
Edge computing and retail locations benefit from its robust design and wide operating temperature range (32°F to 104°F), while healthcare, education, and government facilities rely on its compliance with Energy Star and RoHS standards. The included NETWORK-M3 gigabit network card enables centralized management across distributed deployments.
This section brings together practical product details such as Plug/Connector Type, Receptacle Type, Receptacle Detail, Load Capacity (VA), so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
Physical Profile
This 4U rack-mountable UPS measures 6.80" (172.72 mm) in height, 17.30" (439.42 mm) in width, and 28.60" (726.44 mm) in depth, with a weight of approximately 173.70 lb (78788.99 g). Tower support stands are included for freestanding installations, while integrated rack-mounting hardware simplifies cabinet integration. The compact footprint optimizes space in standard 19-inch racks without sacrificing power density.
The physical profile is practical for deployment planning because the dimensions and weight are clearly defined: 6.80" (172.72 mm), 17.30" (439.42 mm), 28.60" (726.44 mm), 173.70 lb (78788.99 g). This helps confirm rack, shelf, desk, or cabinet fit before installation.
- Width
- 17.30" (439.42 mm)
- Depth
- 28.60" (726.44 mm)
- Height
- 6.80" (172.72 mm)
- Weight
- 173.70 lb (78788.99 g)
What's in the Box
The package includes the Eaton 9PX G2 9PX8KG2 8000VA Rack/Tower UPS, a NETWORK-M3 gigabit network card, USB cable, RS-232 cable, cable gland for hardwire connection, rack-mounting hardware, tower support stands, and a quick start guide.
Highlights
- 8000VA/8kW double conversion online UPS for high-power backup
- 4U rack/tower form factor with included mounting hardware and stands
- 5.4-minute runtime at full load, 15.2 minutes at half load
- 230V AC input with 200-240V AC adjustable pure sine wave output
- Hot-swappable, valve-regulated lead-acid batteries with 3-hour recharge
- Advanced Battery Management (ABM+) extends battery life
- Supports multiple network cards for remote monitoring and management
- Energy Star compliant and RoHS environmental compliance
- Wide operating temperature range from 32°F to 104°F (0°C to 40°C)
- 3-year limited warranty for long-term reliability
Specifications
| Specifications | |
|---|---|
| Manufacturer | Eaton Corporation |
| Manufacturer Part Number | 9PX8KG2 |
| Brand Name | Eaton |
| Product Series | 9PX G2 |
| Product Model | 9PX8KG2 |
| Product Name | 9PX G2 9PX8KG2 8000VA Rack/Tower UPS |
| Product Type | Double Conversion Online UPS |
| Technical Information | |
| Plug/Connector Type | Hardwired |
| Receptacle Type | NEMA L6-30R,Hardwired |
| Receptacle Detail | 4 x NEMA L6-30R |
| EMI/RFI Noise Filter | Yes |
| Phase | Single Phase |
| Efficiency Detail | 96.5% (AC Mode),99.4% (Eco Mode) |
| Application/Usage | Mission Critical Equipment,IT,Edge Computing,Network,Equipment,IT Equipment,Data Center,Business,Education,Government,Healthcare,Retail,Server,PoE System,Switch |
| Surge Suppression | Yes |
| Features | Advanced Battery Management (ABM+) |
| Power Description | |
| Load Capacity (VA) | 8 kVA |
| Load Capacity (Watt) | 8 kW |
| Input Voltage | 230 V AC |
| Input Current | 38.40 A |
| Output Voltage | 200 V AC,208 V AC,220 V AC,230 V AC,240 V AC |
| Output Frequency | 50 Hz,60 Hz |
| Waveform Type | Sine Wave,Pure Sine Wave |
| Output Power Factor | 1 |
| Display & Graphics | |
| Display | LCD |
| Management | |
| Network Management | INDGW-M2 Card,Relay-MS Card,Network-M3 Card,Network Card |
| Alarm | Utility Power Failure,Low Battery,Overload,UPS Fault,Battery Fault,Remote Shutdown |
| Controls/Indicators | |
| Status Indicators | LED Indicators: LED status bar |
| Interfaces/Ports | |
| Serial Port | Yes |
| USB | Yes |
| EPO Port | Yes |
| Battery Information | |
| DC System Voltage | 240 V DC |
| Battery Characteristics | Valve-regulated |
| Battery Chemistry | Lead Acid |
| Backup/Run Time (Full Load) | 5.40 Minute |
| Backup/Run Time (Half Load) | 15.20 Minute |
| Hot Swappable | Yes |
| Typical Battery Recharge Time | 3 Hour |
| Replaceable Battery | Yes |
| Environmental Conditions | |
| Minimum Operating Temperature | 32°F (0°C) |
| Maximum Operating Temperature | 104°F (40°C) |
| Thermal Dissipation | 1137 BTU/h |
| Physical Characteristics | |
| Height | 6.80" (172.72 mm) |
| Width | 17.30" (439.42 mm) |
| Depth | 28.60" (726.44 mm) |
| Rack Height | 4U |
| Form Factor | Rack/Tower |
| Weight (Approximate) | 173.70 lb (78788.99 g) |
| Miscellaneous | |
| Package Contents | 9PX G2 9PX8KG2 8000VA Rack/Tower UPS NETWORK-M3 Gigabit Network Card USB Cable RS-232 Cable Cable Gland for Hardwire Connection Rack-mounting Hardware Tower Support Stands Quick Start Guide |
| Energy Star | Yes |
| Environmental Compliance | Restriction of Hazardous Substances (RoHS) |
| Warranty | |
| Limited Warranty | 3 Year |
User Manual
FAQ
What is the power capacity of the Eaton 9PX8KG2 UPS?
The Eaton 9PX8KG2 provides 8000VA (8 kVA) and 8000 watts of power capacity, making it suitable for protecting high-density server racks, network equipment, and critical IT infrastructure in data center and enterprise environments.
How long can this UPS run on battery power at full load?
At full load (8 kW), the UPS delivers 5.40 minutes of backup runtime. At half load (4 kW), runtime extends to 15.20 minutes, providing sufficient time for graceful shutdowns or transfer to generator power during outages.
What input and output voltages does this UPS support?
The UPS accepts 230V AC input and delivers adjustable output voltages of 200V, 208V, 220V, 230V, or 240V AC. This flexibility ensures compatibility with various electrical systems and equipment requirements across different regions.
Can this UPS be installed in both rack and tower configurations?
Yes, the Eaton 9PX8KG2 is designed as a rack/tower UPS. It occupies 4U of rack space and includes both rack-mounting hardware and tower support stands for flexible deployment in server cabinets or as a standalone unit.
What type of batteries does this UPS use, and are they replaceable?
The UPS uses hot-swappable, valve-regulated lead-acid batteries. These batteries are user-replaceable without shutting down the system, and the typical recharge time after a full discharge is 3 hours, minimizing downtime.
What management and monitoring options are available for this UPS?
The UPS includes an LCD display, LED status indicators, and supports multiple network management cards (INDGW-M2, Relay-MS, Network-M3) for remote monitoring via serial, USB, or EPO ports. Alarms cover utility failure, low battery, overload, and fault conditions.
What power capacity is listed for this UPS?
The listed power specification is 8 kVA, which helps position the unit for the right load level and installation role.
What voltage details are listed?
The listed power specification is 230 V AC, which helps position the unit for the right load level and installation role.